Measurement of anterior chamber volume with rotating scheimpflug camera and anterior segment optical coherence tomography

被引:6
作者
Fu Jing [1 ]
Li Shu-ning [1 ]
Wang Xiao-zhen [1 ]
Wu Ge-wei [2 ]
Mu Da-peng [1 ]
Wang Jian [3 ]
Wang Ning-li [1 ]
机构
[1] Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing 100730, Peoples R China
[2] Beijing Shijingshan Hosp, Dept Ophthalmol, Beijing 100038, Peoples R China
[3] Capital Med Univ, Dept Ophthalmol, Beijing Tiantan Hosp, Beijing 100050, Peoples R China
关键词
rotating scheimpflug camera; anterior segment optical coherence tomography; anterior chamber volume; CORNEAL THICKNESS MEASUREMENT; ACCOMMODATION; REPEATABILITY; DIMENSIONS; ULTRASOUND; PENTACAM;
D O I
10.3760/cma.j.issn.0366-6999.2010.02.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Measurement of anterior segment parameters plays an important role in diagnosis and treatment of glaucoma. The objective of this study was to evaluate the repeatability and reproducibility of anterior chamber volume (ACV) measurements with rotating scheimpflug camera (RSC) and to examine agreement with anterior segment optical coherence tomography (AS-OCT). Methods Thirty nine healthy normal subjects were recruited from the Eye Center of Tongren Hospital. ACV was measured using RSC and AS-OCT in a randomly selected eye for each subject. For RSC measurements, both automatic and manual ACV measurements and 2 independent operators' ACV measurements were obtained. All subjects were invited for 3 visits within a week to evaluate repeatability and reproducibility of ACV measurement by RSC. Agreement was evaluated between RSC and AS-OCT. Results Good repeatability and reproducibility were found for both automatic and manual ACV measurements obtained by RSC. For intrasession repeatability, coefficient of variation (CVw) and intraclass correlation coefficient (ICC) values for automatic were 3.52% and 0.98; the values for manual were 3.44% and 0.97, respectively. For intersession reproducibility, the respective CVw and ICC values were 3.96% and 0.96. Good agreement was also found in 2 operators for both automatic and manual ACV measurements; nevertheless, poor agreement was found between RSC and AS-OCT (95% confidence interval (CI) for agreement of automatic RSC measurement versus AS-OCT were -96.3 to 72.8 mu l and 95% Cl for agreement of manual RSC measurement versus AS-OCT were between -41.7 to 10.1 mu l). Conclusions Both RSC automatic and manual ACV measurements showed good repeatability and reproducibility, and showed comparable agreement between 2 independent operators, but poor agreement was found between RSC and AS-OCT Chin Med J 2010;123(2):203-207
引用
收藏
页码:203 / 207
页数:5
相关论文
共 13 条
[1]   Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry [J].
Barkana, Y ;
Gerber, Y ;
Elbaz, U ;
Schwartz, S ;
Ken-Dror, G ;
Avni, I ;
Zadok, D .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1729-1735
[2]   Accommodation-induced changes in iris curvature [J].
Dorairaj, Syril ;
Oliveira, Cristiano ;
Fose, Amanda K. ;
Liebmann, Jeffrey M. ;
Tello, Celso ;
Barocas, Victor H. ;
Ritch, Robert .
EXPERIMENTAL EYE RESEARCH, 2008, 86 (02) :220-225
[3]   Accommodative microfluctuations and iris contour [J].
Huang, Eric C. ;
Barocas, Victor H. .
JOURNAL OF VISION, 2006, 6 (05) :653-660
[4]  
JOHNSON SB, 1977, INVEST OPHTH VIS SCI, V16, P633
[5]   SIMPLE PHOTOGRAMMETRIC METHOD OF MEASURING ANTERIOR-CHAMBER VOLUME [J].
JOHNSON, SB ;
COAKES, RL ;
BRUBAKER, RF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1978, 85 (04) :469-474
[6]   A SIMPLE PHOTOGRAPHIC METHOD OF MEASURING THE VOLUME OF THE ANTERIOR CHAMBER [J].
JONES, RF ;
MAURICE, DM .
EXPERIMENTAL EYE RESEARCH, 1963, 2 (03) :233-236
[7]   Anterior movement of the crystalline lens in the process of accommodation in children [J].
Kaluzny, B. J. .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2007, 17 (04) :515-520
[8]   Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound [J].
Lackner, B ;
Schmidinger, G ;
Pieh, S ;
Funovics, MA ;
Skorpik, C .
OPTOMETRY AND VISION SCIENCE, 2005, 82 (10) :892-899
[9]  
LEE DA, 1984, ARCH OPHTHALMOL-CHIC, V102, P46
[10]  
MAPSTONE R, 1985, ARCH OPHTHALMOL-CHIC, V103, P1485