Measurement of anterior chamber volume with rotating scheimpflug camera and anterior segment optical coherence tomography

被引:6
|
作者
Fu Jing [1 ]
Li Shu-ning [1 ]
Wang Xiao-zhen [1 ]
Wu Ge-wei [2 ]
Mu Da-peng [1 ]
Wang Jian [3 ]
Wang Ning-li [1 ]
机构
[1] Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing 100730, Peoples R China
[2] Beijing Shijingshan Hosp, Dept Ophthalmol, Beijing 100038, Peoples R China
[3] Capital Med Univ, Dept Ophthalmol, Beijing Tiantan Hosp, Beijing 100050, Peoples R China
关键词
rotating scheimpflug camera; anterior segment optical coherence tomography; anterior chamber volume; CORNEAL THICKNESS MEASUREMENT; ACCOMMODATION; REPEATABILITY; DIMENSIONS; ULTRASOUND; PENTACAM;
D O I
10.3760/cma.j.issn.0366-6999.2010.02.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Measurement of anterior segment parameters plays an important role in diagnosis and treatment of glaucoma. The objective of this study was to evaluate the repeatability and reproducibility of anterior chamber volume (ACV) measurements with rotating scheimpflug camera (RSC) and to examine agreement with anterior segment optical coherence tomography (AS-OCT). Methods Thirty nine healthy normal subjects were recruited from the Eye Center of Tongren Hospital. ACV was measured using RSC and AS-OCT in a randomly selected eye for each subject. For RSC measurements, both automatic and manual ACV measurements and 2 independent operators' ACV measurements were obtained. All subjects were invited for 3 visits within a week to evaluate repeatability and reproducibility of ACV measurement by RSC. Agreement was evaluated between RSC and AS-OCT. Results Good repeatability and reproducibility were found for both automatic and manual ACV measurements obtained by RSC. For intrasession repeatability, coefficient of variation (CVw) and intraclass correlation coefficient (ICC) values for automatic were 3.52% and 0.98; the values for manual were 3.44% and 0.97, respectively. For intersession reproducibility, the respective CVw and ICC values were 3.96% and 0.96. Good agreement was also found in 2 operators for both automatic and manual ACV measurements; nevertheless, poor agreement was found between RSC and AS-OCT (95% confidence interval (CI) for agreement of automatic RSC measurement versus AS-OCT were -96.3 to 72.8 mu l and 95% Cl for agreement of manual RSC measurement versus AS-OCT were between -41.7 to 10.1 mu l). Conclusions Both RSC automatic and manual ACV measurements showed good repeatability and reproducibility, and showed comparable agreement between 2 independent operators, but poor agreement was found between RSC and AS-OCT Chin Med J 2010;123(2):203-207
引用
收藏
页码:203 / 207
页数:5
相关论文
共 50 条
  • [1] Comparison of a New Swept-Source Anterior Segment Optical Coherence Tomography and a Scheimpflug Camera for Measurement of Corneal Curvature
    Zhang, Ting
    Zhou, Yijing
    Young, Charlotte Aimee
    Chen, Aiming
    Jin, Guangming
    Zheng, Danying
    CORNEA, 2020, 39 (07) : 818 - 822
  • [2] Anterior segment parameters of rabbits with rotating Scheimpflug camera
    Yuksel, Harun
    Turkcu, Fatih M.
    Ari, Seyhmus
    Cinar, Yasin
    Cingu, Abdullah K.
    Sahin, Muhammed
    Sahin, Alparslan
    Ozkurt, Zeynep
    Caca, Ihsan
    VETERINARY OPHTHALMOLOGY, 2015, 18 (03) : 210 - 213
  • [3] Comparative study of anterior segment measurement with Pentacam and anterior segment optical coherence tomography
    Fu, Jing
    Wang, Xiaozhen
    Li, Shuning
    Wu, Gewei
    Wang, Ningli
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2010, 45 (06): : 627 - 631
  • [4] Evaluation of the Narrow Anterior Chamber Angle by Anterior Segment Optical Coherence Tomography
    Lan, Jie
    Sun, Dapeng
    Alabdulrasool, Khatoon
    Yusuf, Hassan Ebrahim
    Zhang, Lu
    OPHTHALMIC RESEARCH, 2017, 57 (02) : 87 - 91
  • [5] Comparison of a new anterior segment optical coherence tomography and Oculus Pentacam for measurement of anterior chamber depth and corneal thickness
    Li, Xuepei
    Zhou, Yijing
    Young, Charlotte Aimee
    Chen, Aiming
    Jin, Guangming
    Zheng, Danying
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (14)
  • [6] Comparison of anterior segment measurements with rotating Scheimpflug photography and partial coherence reflectometry
    Huang, Jinhai
    Pesudovs, Konrad
    Wen, Daizong
    Chen, Shihao
    Wright, Thomas
    Wang, Xiaoyu
    Li, Yini
    Wang, Qinmei
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02) : 341 - 348
  • [7] Assessment of corneal thickness measurement using swept-source Fourier-domain anterior segment optical coherence tomography and Scheimpflug camera
    Huang, Jinhai
    Feng, Yifan
    Wang, Qinmei
    Pesudovs, Konrad
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07) : 1305 - 1306
  • [8] Measurement of early changes in anterior chamber morphology after cataract extraction measured by anterior segment optical coherence tomography
    Kasai, Kozue
    Takahashi, Genichiro
    Kumegawa, Koichi
    Dogru, Murat
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (10) : 1751 - 1756
  • [9] Measurement of early changes in anterior chamber morphology after cataract extraction measured by anterior segment optical coherence tomography
    Kozue Kasai
    Genichiro Takahashi
    Koichi Kumegawa
    Murat Dogru
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2015, 253 : 1751 - 1756
  • [10] Assessment of the Anterior Chamber Angle in Patients with Nanophthalmos: An Anterior Segment Optical Coherence Tomography Study
    Kara, Necip
    Baz, Okkes
    Altinkaynak, Hasan
    Altan, Cigdem
    Demirok, Ahmet
    CURRENT EYE RESEARCH, 2013, 38 (05) : 563 - 568