Geometry optimization of uncoated silicon microcantilever-based gas density sensors

被引:27
作者
Boudjiet, M. T. [1 ]
Bertrand, J. [2 ]
Mathieu, F. [3 ]
Nicu, L. [3 ]
Mazenq, L. [3 ]
Leichle, T. [3 ]
Heinrich, M. [4 ]
Pellet, C. [1 ]
Dufour, I. [1 ]
机构
[1] Univ Bordeaux, IMS, UMR 5218, F-33400 Talence, France
[2] Andra, F-92298 Chatenay Malabry, France
[3] CNRS, LAAS, F-31077 Toulouse, France
[4] Marquette Univ, Dept Civil Construct & Environm Engn, Milwaukee, WI USA
关键词
Density sensor; Hydrogen sensor; Geometry optimization; Sensitivity optimization; Euler-Bernoulli beam theory; Hydrodynamic function; FREQUENCY; SENSITIVITY; FLUIDS;
D O I
10.1016/j.snb.2014.11.067
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the absence of coating, the only way to improve the sensitivity of silicon microcantilever-based density sensors is to optimize the device geometry. Based on this idea, several microcantilevers with different shapes (rectangular-, U- and T-shaped microstructures) and dimensions have been fabricated and tested in the presence of hydrogen/nitrogen mixtures (H-2/N-2) of various concentrations ranging from 0.2% to 2%. In fact, it is demonstrated that wide and short rectangular cantilevers are more sensitive to gas density changes than U- and T-shaped devices of the same overall dimensions, and that the thickness does not affect the sensitivity despite the fact that it affects the resonant frequency. Moreover, because of the phase linearization method used for the natural frequency estimation, detection of a gas mass density change of 2 mg/l has been achieved with all three microstructures. In addition, noise measurements have been used to estimate a limit of detection of 0.11 mg/l for the gas mass density variation (corresponding to a concentration of 100 ppm of H-2 in N-2), which is much smaller than the current state of the art for uncoated mechanical resonators. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:600 / 607
页数:8
相关论文
共 27 条
[1]   Deflection, Frequency, and Stress Characteristics of Rectangular, Triangular, and Step Profile Microcantilevers for Biosensors [J].
Ansari, Mohd Zahid ;
Cho, Chongdu .
SENSORS, 2009, 9 (08) :6046-6057
[2]   Geometrical considerations for the design of liquid-phase biochemical sensors using a cantilever's fundamental in-plane mode [J].
Beardslee, L. A. ;
Josse, F. ;
Heinrich, S. M. ;
Dufour, I. ;
Brand, O. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 164 (01) :7-14
[3]  
Bergaud C, 2002, PROC IEEE MICR ELECT, P360, DOI 10.1109/MEMSYS.2002.984277
[4]   Real-Time Viscosity and Mass Density Sensors Requiring Microliter Sample Volume Based on Nanomechanical Resonators [J].
Bircher, Benjamin A. ;
Duempelmann, Luc ;
Renggli, Kasper ;
Lang, Hans Peter ;
Gerber, Christoph ;
Bruns, Nico ;
Braun, Thomas .
ANALYTICAL CHEMISTRY, 2013, 85 (18) :8676-8683
[5]  
Blevins R.D., 1979, Formulas for natural frequency and mode shape, DOI DOI 10.1115/1.3153712
[6]   Cantilever-like micromechanical sensors [J].
Boisen, Anja ;
Dohn, Soren ;
Keller, Stephan Sylvest ;
Schmid, Silvan ;
Tenje, Maria .
REPORTS ON PROGRESS IN PHYSICS, 2011, 74 (03)
[7]   New characterization methods for monitoring small resonant frequency variation: Experimental tests in the case of hydrogen detection with uncoated silicon microcantilever-based sensors [J].
Boudjiet, M. T. ;
Bertrand, J. ;
Pellet, C. ;
Dufour, I. .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 199 :269-276
[8]  
Boudjiet M. T., 2014, INT J HYDROGEN ENERG
[9]  
Fadel-Taris L., 2011, PROC IEEE INT FREQ C, P1
[10]   Microcantilevers: Sensing chemical interactions via mechanical motion [J].
Goeders, Karen M. ;
Colton, Jonathan S. ;
Bottomley, Lawrence A. .
CHEMICAL REVIEWS, 2008, 108 (02) :522-542