Factors Affecting Slip Progression After In Situ Screw Fixation of Stable Slipped Capital Femoral Epiphysis

被引:2
作者
Makarewich, Christopher A. [1 ,2 ,3 ]
Wait, Eric S. [1 ,2 ,3 ]
Fedorak, Graham T. [1 ,2 ,3 ]
MacWilliams, Bruce A. [1 ,3 ]
机构
[1] Univ Utah, Dept Orthopaed, 590 Wakara Way, Salt Lake City, UT 84108 USA
[2] Primary Childrens Med Ctr, Salt Lake City, UT USA
[3] Shriners Childrens, Salt Lake City, UT USA
关键词
slipped capital femoral epiphysis; SCFE; stable; progression; screw; fixation; threads; in situ; SINGLE-SCREW; INTERNAL-FIXATION; RELIABILITY;
D O I
10.1097/BPO.0000000000002098
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Slip progression after in situ fixation of slipped capital femoral epiphysis (SCFE) has been reported as occurring in up to 20% of patients. We review SCFE treated with in situ single screw fixation performed at 2 hospitals over a 15-year period to determine the factors associated with slip progression. Methods: This case-control study reviews SCFE treated with in situ single cannulated screw fixation with minimum follow up of 1 year and full closure of the affected physis. Slip progression (failure) was defined as worsening of the Southwick slip angle of 10 or more degrees or revision surgery for symptomatic slip progression. Univariate and multivariate analyses were performed comparing success and failure groups for patient characteristics, screw type and position, and radiographic measurements. Results: Ninety three patients with 108 slips met all criteria, with 15 hips (14%) classified as having slip progression (failure). All failures had 3 threads or fewer across the physis. Five hips had 2 threads across the physis, and 4 of the 5 were classified as failures. Lower modified Oxford bone scores were found in the failure group, though the difference was small (0.9, P=0.013). Failure was also associated with partially threaded screws (P=0.001). Failed hips were associated with lower initial Southwick angles (32.8 degrees) than successful hips (40.4 degrees) (P=0.047). In the stepwise model for multivariate regression, 4 factors were identified as significant, with lower initial number of threads (P<0.0001), mild initial Southwick category (P=0.0050), male sex (P=0.0061), and partially threaded screw type (P=0.0116) predicting failure. Conclusion: This study is the largest to date evaluating risk factors for slip progression after SCFE fixation, and the first to consider revision surgery for symptomatic slip progression. For stable SCFE, we demonstrate that 4 threads across the physis with a fully threaded screw of 6.5 mm diameter or greater was sufficient to avoid slip progression. We provide a risk stratification for progression of slip showing that in some cases 3 threads across the physis may be sufficient.
引用
收藏
页码:E414 / E420
页数:7
相关论文
共 23 条
  • [1] ARONSON DD, 1992, CLIN ORTHOP RELAT R, P115
  • [2] SLIPPED CAPITAL FEMORAL EPIPHYSIS - A PROSPECTIVE-STUDY OF FIXATION WITH A SINGLE SCREW
    ARONSON, DD
    CARLSON, WE
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06) : 810 - 819
  • [3] Slipped capital femoral epiphysis: Current concepts
    Aronsson, David D.
    Loder, Randall T.
    Breur, Gert J.
    Weinstein, Stuart L.
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2006, 14 (12) : 666 - 679
  • [4] Slip progression after in situ single screw fixation for stable slipped capital femoral epiphysis
    Carney, BT
    Birnbaum, P
    Minter, C
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2003, 23 (05) : 584 - 589
  • [5] PERCUTANEOUS IN SITU FIXATION OF SLIPPED CAPITAL FEMORAL EPIPHYSIS
    Chlebeck, Jesse D.
    Birch, Christopher E.
    Lisle, Jennifer W.
    [J]. JBJS ESSENTIAL SURGICAL TECHNIQUES, 2016, 6 (01):
  • [6] STRATEGIES TO AVOID OSTEONECROSIS IN UNSTABLE SLIPPED CAPITAL FEMORAL EPIPHYSIS A Critical Analysis Review
    Daley, Erika
    Zaltz, Ira
    [J]. JBJS REVIEWS, 2019, 7 (04)
  • [7] Reliability of Predictors for Screw Cutout in Intertrochanteric Hip Fractures
    De Bruijn, Kirstin
    den Hartog, Dennis
    Tuinebreijer, Wim
    Roukema, Gert
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (14) : 1266 - 1272
  • [8] Biomechanical Study of 16-mm Threaded, 32-mm Threaded, and Fully Threaded SCFE Screw Fixation
    Dragoni, Massimiliano
    Heiner, Anneliese Dorothy
    Costa, Simone
    Gabrielli, Armando
    Weinstein, Stuart L.
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2012, 32 (01) : 70 - 74
  • [9] Lateral insertion is a good prognostic factor after in situ fixation in slipped capital femoral epiphysis
    Hagiwara, Shigeo
    Nakamura, Junichi
    Kamegaya, Makoto
    Saisu, Takashi
    Kakizaki, Jun
    Ohtori, Seiji
    Kishida, Shunji
    Takahashi, Kazuhisa
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [10] Good inter- and intraobserver reliability for assessment of the slip angle in 77 hip radiographs of children with a slipped capital femoral epiphysis
    Herngren, Bengt
    Lindell, Mikael
    Hagglund, Gunnar
    [J]. ACTA ORTHOPAEDICA, 2018, 89 (02) : 217 - 221