Alendronate inhibits bone resorption at the bone-screw interface

被引:7
|
作者
Miyaji, T
Nakase, T
Azuma, Y
Shimizu, N
Uchiyama, Y
Yoshikawa, H
机构
[1] Osaka Univ, Sch Med, Dept Orthoped Surg, Suita, Osaka 5650871, Japan
[2] Teijin Ltd, Teijin Inst Biomed Res, Pharmacol Res Dept, Hino, Tokyo, Japan
[3] Osaka Univ, Sch Med, Dept Cell Biol & Neurosci, Suita, Osaka 5650871, Japan
关键词
D O I
10.1097/01.blo.0000137553.91189.67
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In the current study, we investigated whether the systemic administration of alendronate, a third-generation bisphosphonate, suppressed the loosening of screws at the bone-screw interface. We systemically administered alendronate to rats fitted with external fixators. External fixators with two half pins were applied to the right femurs of rats, and alendronate was administrated once a week during a 5-week postoperative period. Radiographic, histologic, and immunohistochemical findings subsequently were analyzed. Treatment with alendronate reduced the width of the fibrous loosening membrane and the number of osteoclasts at the bonescrew interface. These findings indicate that systemic treatment with alendronate exerts an inhibitory effect on local bone resorption at the bone-screw interface.
引用
收藏
页码:195 / 201
页数:7
相关论文
共 50 条
  • [1] Remodeling along the bone-screw interface
    Praeger, Thomas Michael
    Mischkowski, Robert
    Laube, Nico
    Jost-Brinkmann, Paul-Georg
    Mueller-Hartwich, Ralf
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2008, 69 (05): : 337 - 348
  • [2] Axial cyclic behavior of the bone-screw interface
    Inceoglu, Serkan
    Ehlert, Mike
    Akbay, Atilla
    McLain, Robert F.
    MEDICAL ENGINEERING & PHYSICS, 2006, 28 (09) : 888 - 893
  • [3] The radiographic classification of the bone-screw interface in paediatric tibial lengthening
    McAndrew, Andrew R.
    Saleh, Michael
    Rigby, Alan S.
    Donnan, Leo T.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2007, 16 (05): : 305 - 311
  • [4] A BIOMECHANICAL STUDY OF SHEAR LOAD ON BONE-SCREW INTERFACE OF THORACOLUMBAR VERTEBRAE
    Wang, Jiang-Ze
    Zhang, Feng
    You, Ming-Liang
    Sha, Mo
    Liang, Bo-Wei
    Liang, Dong-Zhu
    Ding, Zhen-Qi
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2015, 15 (06)
  • [5] Microradiographic and histological evaluation of the bone-screw and bone-plate interface of orthodontic miniplates in patients
    Vandergugten, Simon
    Cornelis, Marie A.
    Mahy, Pierre
    Nyssen-Behets, Catherine
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (03) : 325 - 329
  • [6] A SIMPLE BONE-SCREW MEASURING DEVICE
    HALL, MH
    LANCET, 1955, 2 (OCT8): : 753 - 753
  • [7] Remodeling along the Bone-screw Interface [Remodelling am Knochen-Schraube-Interface]
    Präger T.M.
    Mischkowski R.
    Laube N.
    Jost-Brinkmann P.-G.
    Müller-Hartwich R.
    Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2008, 69 (5): : 337 - 348
  • [8] Comparison of simplified bone-screw interface models in materially nonlinear μFE simulations
    Stefanek, Pia
    Pahr, Dieter H.
    Synek, Alexander
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 157
  • [9] Biomechanical and histomorphometric study of the bone-screw interface of calcium pyrophosphate coated titanium screws
    Lee, JH
    Ryu, HS
    Lee, DS
    Hong, KS
    Chang, BS
    Lee, CK
    BIOCERAMICS 17, 2005, 284-286 : 219 - 222
  • [10] The effect of alendronate on resorption of transplanted bone
    Tenjo, K
    Kawata, T
    Tokimasa, C
    Kohno, S
    Kaku, M
    Fujita, T
    Tsutsui, K
    Tohma, Y
    Ohtani, J
    Motokawa, M
    Kobayakawa, T
    Shigekawa, M
    Tanne, K
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 392 - 392