Fluorescence lifetime imaging microscopy and time-resolved anisotropy of nanomaterial-induced changes to red blood cell membranes

被引:2
|
作者
Sydor, Matthew J. [1 ]
Anderson, Donald S. [1 ]
Steele, Harmen B. B. [2 ,3 ]
Ross, J. B. Alexander [2 ,3 ]
Holian, Andrij [1 ]
机构
[1] Univ Montana, Ctr Environm Hlth Sci, Dept Biomed & Pharmaceut Sci, Missoula, MT 59812 USA
[2] Univ Montana, Dept Chem & Biochem, Missoula, MT 59812 USA
[3] Univ Montana, Ctr Biomol Struct & Dynam, Missoula, MT 59812 USA
来源
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
FLIM; fluorescence lifetime; engineered nano-material; TITANIUM-DIOXIDE NANOPARTICLES; LIPID ORDER; IN-VITRO; TOXICITY; SIZE; INTERLEUKIN-1; INFLAMMASOME; ACTIVATION; SILICA;
D O I
10.1088/2050-6120/abf424
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
With the use of engineered nano-materials (ENM) becoming more prevalent, it is essential to determine potential human health impacts. Specifically, the effects on biological lipid membranes will be important for determining molecular events that may contribute to both toxicity and suitable biomedical applications. To better understand the mechanisms of ENM-induced hemolysis and membrane permeability, fluorescence lifetime imaging microscopy (FLIM) was performed on human red blood cells (RBC) exposed to titanium dioxide ENM, zinc oxide ENM, or micron-sized crystalline silica. In the FLIM images, changes in the intensity-weighted fluorescence lifetime of the lipophilic fluorescence probe Di-4-ANEPPDHQ were used to identify localized changes to membrane. Time-resolved fluorescence anisotropy and FLIM of RBC treated with methyl-ss-cyclodextrin was performed to aid in interpreting how changes to membrane order influence changes in the fluorescence lifetime of the probe. Treatment of RBC with methyl-ss-cyclodextrin caused an increase in the wobble-in-a-cone angle and shorter fluorescence lifetimes of di-4-ANEPPDHQ. Treatment of RBC with titanium dioxide caused a significant increase in fluorescence lifetime compared to non-treated samples, indicating increased membrane order. Crystalline silica also increased the fluorescence lifetime compared to control levels. In contrast, zinc oxide decreased the fluorescence lifetime, representing decreased membrane order. However, treatment with soluble zinc sulfate resulted in no significant change in fluorescence lifetime, indicating that the decrease in order of the RBC membranes caused by zinc oxide ENM was not due to zinc ions formed during potential dissolution of the nanoparticles. These results give insight into mechanisms for how these three materials might disrupt RBC membranes and membranes of other cells. The results also provide evidence for a direct correlation between the size, interaction-available surface area of the nano-material and cell membrane disruption.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Ca2+ measurements in red blood cells with fluorescence lifetime imaging microscopy
    Schweizer, J.
    Sauer, B.
    Kaestner, L.
    Lipp, P.
    ACTA PHYSIOLOGICA, 2014, 210 : 182 - 182
  • [42] Time-Resolved Four-Tap Lock-In Pixel CMOS Image Sensor for Real-Time Fluorescence Lifetime Imaging Microscopy
    Seo, Min-Woong
    Shirakawa, Yuya
    Kawata, Yoshimasa
    Kagawa, Keiichiro
    Yasutomi, Keita
    Kawahito, Shoji
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2018, 53 (08) : 2319 - 2330
  • [43] Time-resolved fluorescence microscopy for quantitative Ca2+ imaging in living cells
    Kristina Sagolla
    Hans-Gerd Löhmannsröben
    Carsten Hille
    Analytical and Bioanalytical Chemistry, 2013, 405 : 8525 - 8537
  • [44] Time-resolved fluorescence microscopy for quantitative Ca2+ imaging in living cells
    Sagolla, Kristina
    Loehmannsroeben, Hans-Gerd
    Hille, Carsten
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (26) : 8525 - 8537
  • [45] Time-resolved polarization imaging by pump-probe (stimulated emission) fluorescence microscopy
    Buehler, C
    Dong, CY
    So, PTC
    French, T
    Gratton, E
    BIOPHYSICAL JOURNAL, 2000, 79 (01) : 536 - 549
  • [46] Fully time-resolved near-field scanning optical microscopy fluorescence imaging
    Kwak, ES
    Vanden Bout, DA
    ANALYTICA CHIMICA ACTA, 2003, 496 (1-2) : 259 - 266
  • [47] Persistent luminescence nanoprobe for biosensing and lifetime imaging of cell apoptosis via time-resolved fluorescence resonance energy transfer
    Zhang, Lei
    Lei, Jianping
    Liu, Jintong
    Ma, Fengjiao
    Ju, Huangxian
    BIOMATERIALS, 2015, 67 : 323 - 334
  • [48] Time-resolved microspectrofluorimetry and fluorescence lifetime imaging of hypericin in human retinal pigment epithelial cells
    Taroni, P
    Valentini, G
    Comelli, D
    D'Andrea, C
    Cubeddu, R
    Hu, DN
    Roberts, JE
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2005, 81 (03) : 524 - 528
  • [49] Mapping the Spatiotemporal Heterogeneity of Biomolecules Concentration, Mobility and Local Environment in Live Cells using Quantitative Time-Resolved Confocal Fluorescence Microscopy Imaging Without Scanning and Fluorescence Lifetime Imaging Microscopy
    Oasa, Sho
    Krmpot, Aleksandar
    Nikolic, Stanko
    Terenius, Lars
    Rigler, Rudolf
    Vukojevic, Vladana
    BIOPHYSICAL JOURNAL, 2020, 118 (03) : 307A - 307A
  • [50] Time-resolved fluorescence polarization anisotropy and optical imaging of Cybesin in cancerous and normal prostate tissues
    Pu, Y.
    Wang, W. B.
    Achilefu, S.
    Das, B. B.
    Tang, G. C.
    Sriramoju, V.
    Alfano, R. R.
    OPTICS COMMUNICATIONS, 2007, 274 (01) : 260 - 267