A diagnostic analysis of ultrasound elastography and contrast-enhanced ultrasound in focal liver lesions

被引:0
作者
Wang, Yongqing [1 ]
Lu, Pingping [1 ]
Cui, Yuanping [2 ]
Zhang, Xiaohong [2 ]
机构
[1] PKU Care Luan Hosp, Dept Ultrasonog, Changzhi 046204, Shanxi, Peoples R China
[2] Shanxi Prov Peoples Hosp, Dept Ultrasonog, Taiyuan, Shanxi, Peoples R China
来源
INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE | 2019年 / 12卷 / 10期
关键词
Ultrasound elastography; contrast-enhanced ultrasound; focal liver lesions; diagnostic accuracy; differentiation of malignant and benign lesions; BENIGN; STRAIN; ULTRASONOGRAPHY;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To compare the diagnostic value of ultrasound elastography (UE) and contrast-enhanced ultrasound (CEUS) in focal liver lesions. Methods: Eighty-nine patients with focal liver lesions were included as subjects. All were examined by both UE and CEUS prior to the operation or puncture. The diagnostic accuracy of UE and CEUS was compared with puncture biopsy or postoperative pathological diagnosis results which served as gold standards. Results: Through the pathological diagnosis, the research subjects consisted of 42 patients with benign lesions and 55 patients with malignant lesions. The Kappa coefficient of the UE diagnosis for the focal liver lesions and the pathological diagnosis was 0.57 (P<0.05); the sensitivity, specificity and accuracy of the UE diagnosis for the malignant focal liver lesions were 76.36%, 80.95%, and 78.35%, respectively. The Kappa coefficient of the CEUS diagnosis for the focal liver lesions and pathological diagnosis was 0.81 (P<0.05); the sensitivity, specificity and accuracy of the CEUS diagnosis for the malignant focal liver lesions were 92.73%, 88.10%, and 90.72%, respectively. The analysis of the receiver operating characteristic (ROC) curve indicated that the area under the curve, the sensitivity, specificity, and accuracy of the diagnosis of UE combined with CEUS for malignant focal liver lesions were 0.90, 100%, 80.95% and 91.75%, respectively. Conclusion: UE can objectively reflect changes in the stiffness of focal liver lesions. CEUS reveals the changes of blood supply within the lesions in terms of microcirculation. Both methods have good diagnostic value. The combined application of UE and CEUS can improve diagnostic accuracy for focal liver lesions.
引用
收藏
页码:12331 / 12339
页数:9
相关论文
共 50 条
  • [31] Shear-wave elastography combined with contrast-enhanced ultrasound algorithm for noninvasive characterization of focal liver lesions
    Si-min Ruan
    Hui Huang
    Mei-qing Cheng
    Man-xia Lin
    Hang-tong Hu
    Yang Huang
    Ming-de Li
    Ming-de Lu
    Wei Wang
    La radiologia medica, 2023, 128 : 6 - 15
  • [32] Heterogeneity in patient diagnostic pathways: An example from contrast-enhanced ultrasound diagnostic scans for focal liver lesions
    Smith A.B.
    Filby A.
    Carr L.M.
    BMC Research Notes, 7 (1)
  • [33] Diagnostic Performance and Confidence of Contrast-Enhanced Ultrasound in the Differential Diagnosis of Cystic and Cysticlike Liver Lesions
    Corvino, Antonio
    Catalano, Orlando
    Corvino, Fabio
    Sandomenico, Fabio
    Petrillo, Antonella
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (03) : W119 - W127
  • [34] Contrast-enhanced ultrasound of liver lesions in children
    Alexander M. El-Ali
    James C. Davis
    Jennifer M. Cickelli
    Judy H. Squires
    Pediatric Radiology, 2019, 49 : 1422 - 1432
  • [35] AUTOMATIC IDENTIFICATION OF THE OPTIMAL REFERENCE FRAME FOR SEGMENTATION AND QUANTIFICATION OF FOCAL LIVER LESIONS IN CONTRAST-ENHANCED ULTRASOUND
    Bakas, Spyridon
    Makris, Dimitrios
    Hunter, Gordon J. A.
    Fang, Cheng
    Sidhu, Paul S.
    Chatzimichail, Katerina
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (10) : 2438 - 2451
  • [36] Ultrasound Elastography for Characterization of Focal Liver Lesions
    Dong, Yi
    Koch, Jonas
    Alhyari, Amjad
    Zadeh, Ehsan Safai
    Gorg, Christian
    Wang, Wen-Ping
    Berzigotti, Annalisa
    Dietrich, Christoph F.
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2023, 61 (04): : 399 - 410
  • [37] Diagnostic accuracy of contrast-enhanced ultrasound in differentiating benign and malignant focal liver lesions: A retrospective study
    Ooi, Chin-Chin
    Low, Su-Chong Albert
    Schneider-Kolsky, Michal
    Lombardo, Paul
    Lim, Sze-Ying
    Abu Bakar, Rafidah
    Lo, Richard Hoau-Gong
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2010, 54 (05) : 421 - 430
  • [38] Diagnostic performance of contrast-enhanced ultrasound for complex cystic focal liver lesions: blinded reader study
    Lin, Man-Xia
    Xu, Hui-Xiong
    Lu, Ming-De
    Xie, Xiao-Yan
    Chen, Li-Da
    Xu, Zuo-Feng
    Liu, Guang-Jian
    Xie, Xiao-Hua
    Liang, Jin-Yu
    Wang, Zhu
    EUROPEAN RADIOLOGY, 2009, 19 (02) : 358 - 369
  • [39] Diagnostic performance of contrast-enhanced ultrasound for complex cystic focal liver lesions: blinded reader study
    Man-Xia Lin
    Hui-Xiong Xu
    Ming-De Lu
    Xiao-Yan Xie
    Li-Da Chen
    Zuo-Feng Xu
    Guang-Jian Liu
    Xiao-Hua Xie
    Jin-Yu Liang
    Zhu Wang
    European Radiology, 2009, 19 : 358 - 369
  • [40] Does the echogenicity of focal liver lesions on baseline gray-scale ultrasound interfere with the diagnostic performance of contrast-enhanced ultrasound?
    Liu, Guang-Jian
    Xu, Hui-Xiong
    Xie, Xiao-Yan
    Xu, Zuo-Feng
    Zheng, Yan-Ling
    Liang, Jin-Yu
    Lu, Ming-De
    Moriyasu, Fuminori
    EUROPEAN RADIOLOGY, 2009, 19 (05) : 1214 - 1222