Semi-Automated Quantification of Retinal and Choroidal Biomarkers in Retinal Vascular Diseases: Agreement of Spectral-Domain Optical Coherence Tomography with and without Enhanced Depth Imaging Mode

被引:8
|
作者
Kessler, Lucy J. [1 ,2 ,3 ]
Bagautdinov, Dmitrii [1 ]
Labuz, Grzegorz [1 ]
Auffarth, Gerd U. [1 ]
Khoramnia, Ramin [1 ,2 ,3 ]
机构
[1] Heidelberg Univ, Dept Ophthalmol, D-69120 Heidelberg, Germany
[2] Heidelberg Univ, HEiKA Heidelberg Karlsruhe Strateg Partnership, D-69120 Heidelberg, Germany
[3] Karlsruhe Inst Technol, HEiKA Heidelberg Karlsruhe Strateg Partnership, D-76131 Karlsruhe, Germany
关键词
optical coherence tomography angiography; biomarkers; enhanced depth imaging; automated quantification; hyperreflective foci; choroidal vascularity index; ellipsoid zone reflectivity ratio; retinal vascular diseases; DIABETIC MACULAR EDEMA; SWEPT-SOURCE; THICKNESS MEASUREMENTS; HYPERREFLECTIVE FOCI; ELLIPSOID ZONE; INTENSITY; THERAPY;
D O I
10.3390/diagnostics12020333
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We compared with and without enhanced depth imaging mode (EDI) in semi-automated quantification of retinal and choroidal biomarkers in optical coherence tomography (OCT) in patients with diabetic retinopathy (DR) or retinal vein occlusion (RVO) complicated by macular edema. We chose to study three OCT biomarkers: the numbers of hyperreflective foci (HF), the ellipsoid zone reflectivity ratio (EZR) and the choroidal vascularity index (CVI), all known to be correlated with visual acuity changes or treatment outcomes. Methods: In a single examination, one eye of each patient (n = 60; diabetic retinopathy: n = 27, retinal vein occlusion: n = 33) underwent macular 870 nm spectral domain-OCT (SD-OCT) B-scans without and with EDI mode. Semi-automated quantification of HF, EZR and CVI was applied according to preexisting published protocols. Paired Student's t-test or Wilcoxon rank-sum test was used to test for differences in subgroups. Intraclass correlation coefficient (ICC) and Bland-Altman plots were applied to describe the agreement between quantification in EDI and conventional OCT mode. The effect of macular edema on semi-automated quantification was evaluated. Results: For the entire cohort, quantification of all three biomarkers was not significantly different in SD-OCT scans with and without EDI mode (p > 0.05). ICC was 0.78, 0.90 and 0.80 for HF, EZR and CVI. The presence of macular edema led to significant differences in the quantification of hyperreflective foci (without EDI: 80.00 +/- 33.70, with EDI: 92.08 +/- 38.11; mean difference: 12.09, p = 0.03), but not in the quantification of EZR and CVI (p > 0.05). Conclusion: Quantification of EZR and CVI was comparable whether or not EDI mode was used. In conclusion, both retinal and choroidal biomarkers can be quantified from one single 870 nm SD-OCT EDI image.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Retinal and choroidal thickness measurements using spectral domain optical coherence tomography in anterior and intermediate uveitis
    Zsuzsanna Géhl
    Kinga Kulcsár
    Huba JM Kiss
    János Németh
    Otto A Maneschg
    Miklós D Resch
    BMC Ophthalmology, 14
  • [32] Spectral Domain Optical Coherence Tomography of Choroidal and Outer Retinal Layer Thickness in the Sturge Weber Syndrome
    Abdolrahimzadeh, Solmaz
    Scavella, Vittorio
    Battaglia, Domenica
    Recupero, Santi Maria
    CURRENT EYE RESEARCH, 2016, 41 (12) : 1614 - 1617
  • [33] Retinal and choroidal thickness measurements using spectral domain optical coherence tomography in anterior and intermediate uveitis
    Gehl, Zsuzsanna
    Kulcsar, Kinga
    Kiss, Huba J. M.
    Nemeth, Janos
    Maneschg, Otto A.
    Resch, Miklos D.
    BMC OPHTHALMOLOGY, 2014, 14
  • [34] Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography A Prospective Analysis of Age-Related Loss
    Leung, Christopher K. S.
    Yu, Marco
    Weinreb, Robert N.
    Ye, Cong
    Liu, Shu
    Lai, Gilda
    Lam, Dennis S. C.
    OPHTHALMOLOGY, 2012, 119 (04) : 731 - 737
  • [35] Impact of segmentation errors and retinal blood vessels on retinal nerve fibre layer measurements using spectral-domain optical coherence tomography
    Ye, Cong
    Yu, Marco
    Leung, Christopher Kai-shun
    ACTA OPHTHALMOLOGICA, 2016, 94 (03) : E211 - E219
  • [36] Comparison Between Spectral-Domain and Swept-Source Optical Coherence Tomography Angiographic Imaging of Choroidal Neovascularization
    Miller, Andrew R.
    Roisman, Luiz
    Zhang, Qinqin
    Zheng, Fang
    Dias, Joao Rafael de Oliveira
    Yehoshua, Zohar
    Schaal, Karen B.
    Feuer, William
    Gregori, Giovanni
    Chu, Zhongdi
    Chen, Chieh-Li
    Kubach, Sophie
    An, Lin
    Stetson, Paul F.
    Durbin, Mary K.
    Wang, Ruikang K.
    Rosenfeld, Philip J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (03) : 1499 - 1505
  • [37] REPEATABILITY AND REPRODUCIBILITY OF RETINAL THICKNESS MEASUREMENTS WITH SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY USING DIFFERENT SCAN PARAMETERS
    Giani, Andrea
    Peroglio, Antonio
    Staurenghi, Giovanni
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2012, 32 (05): : 1007 - 1012
  • [38] Repeatability and Reproducibility of Retinal Neuronal and Axonal Measures on Spectral-Domain Optical Coherence Tomography in Patients with Cognitive Impairment
    Loh, Edwin Hong-Teck
    Ong, Yi-Ting
    Venketasubramanian, Narayanaswamy
    Hilal, Saima
    Thet, Naing
    Wong, Tien Yin
    Chen, Christopher P. L.
    Cheung, Carol Yim-Lui
    FRONTIERS IN NEUROLOGY, 2017, 8
  • [39] Comparison of Retinal Thicknesses Measured Using Swept-Source and Spectral-Domain Optical Coherence Tomography Devices
    Tan, Colin S.
    Chan, Joel C.
    Cheong, Kai Xiong
    Ngo, Wei Kiong
    Sadda, SriniVas R.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2015, 46 (02): : 172 - 179
  • [40] Retinal neurodegeneration in patients with end-stage renal disease assessed by spectral-domain optical coherence tomography
    Jung, Susanne
    Bosch, Agnes
    Ott, Christian
    Kannenkeril, Dennis
    Dienemann, Thomas
    Harazny, Joanna M.
    Michelson, Georg
    Schmieder, Roland E.
    SCIENTIFIC REPORTS, 2020, 10 (01)