Validation of a Standardized Home Visual Acuity Test for Teleophthalmology

被引:10
作者
Siktberg, Jonathan [1 ]
Hamdan, Saif [1 ]
Liu, Yuhan [2 ]
Chen, Qingxia [2 ]
Donahue, Sean P. [3 ]
Patel, Shriji N. [3 ]
Sternberg, Paul, Jr. [3 ]
Robinson, Joshua [3 ]
Kammer, Jeffrey A. [3 ]
Gangaputra, Sapna S. [3 ,4 ]
机构
[1] Vanderbilt Univ, Vanderbilt Eye Inst, Sch Med, Nashville, TN USA
[2] Vanderbilt Univ, Dept Biostat, Nashville, TN USA
[3] Vanderbilt Univ, Vanderbilt Eye Inst, Sch Med, 2311 Pierce Ave,Suite 2251, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Vanderbilt Eye Inst, Sch Med, 2311 Pierce Ave,Suite 2251, Nashville, TN 37232 USA
来源
OPHTHALMOLOGY SCIENCE | 2021年 / 1卷 / 01期
关键词
Home visual acuity chart; Remote ETDRS chart; Telehealth; Tele-ophthalmology; Visual acuity; DIABETIC-RETINOPATHY; SNELLEN; ETDRS; CHART; ADULTS;
D O I
10.1016/j.xops.2021.100007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The recent exponential growth in teleophthalmology has been limited in part by the lack of a validated method to measure visual acuity (VA) remotely. We investigated the validity of a self-administered Early Treatment Diabetic Retinopathy Study (ETDRS) home VA test. We hypothesized that a home VA test with a printout ETDRS chart is equivalent to a standard technician-administered VA test in clinic.Design: Prospective cohort study.Participants: Two hundred nine eyes from 108 patients who had a scheduled in-person outpatient ophthalmology clinic visit at an academic medical center.Methods: Enrolled patients were sent a .pdf document consisting of instructions and a printout ETDRS vision chart calibrated for 5 feet. Patients completed the VA test at home before the in-person appointment, where their VA was measured by an ophthalmic technician using a standard ETDRS chart. Survey questions about the ease of testing and barriers to completion were administered. For the bioequivalence test with a 5% nominal level, the 2 1-sided tests procedure was used, and an equivalent 90% confidence interval (CI) was constructed and compared with the prespecified 7-letter equivalence margin.Main Outcome Measures: The primary outcome was the mean adjusted letter score difference between the home and clinic tests. Secondary outcomes included the unadjusted letter difference, absolute letter difference, and survey question responses.Results: The mean adjusted VA letter score difference was 4.1 letters (90% CI, 3.2-4.9 letters), well within the 7-letter equivalence margin. Average unadjusted VA scores in clinic were 3.9 letters (90% CI, 3.1-4.7 letters) more than scores at home. The absolute difference was 5.2 letters (90% CI, 4.6-5.9 letters). Ninety-eight percent of patients agreed that the home test was easy to perform.Conclusions: An ETDRS VA test self-administered at home following a standardized protocol was equivalent to a standard technician-administered VA test in clinic in the examined population. Ophthalmology Science 2021;1:100007 & COPY; 2021 by the American Academy of Ophthalmology. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:8
相关论文
共 30 条
[11]   Comparison of visual acuity in macular degeneration patients measured with Snellen and Early Treatment Diabetic Retinopathy Study Charts [J].
Falkenstein, Iryna A. ;
Cochran, Denine E. ;
Azen, Stanley P. ;
Dustin, Laurie ;
Tammewar, Ajay M. ;
Kozak, Igor ;
Freeman, William R. .
OPHTHALMOLOGY, 2008, 115 (02) :319-323
[12]   NOVEL METHOD FOR ANALYZING SNELLEN VISUAL ACUITY MEASUREMENTS [J].
Gregori, Ninel Z. ;
Feuer, William ;
Rosenfeld, Philip J. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2010, 30 (07) :1046-1050
[13]   Development and Validation of a Smartphone-Based Visual Acuity Test (Vision at Home) [J].
Han, Xiaotong ;
Scheetz, Jane ;
Keel, Stuart ;
Liao, Chimei ;
Liu, Chi ;
Jiang, Yu ;
Muller, Andreas ;
Meng, Wei ;
He, Mingguang .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2019, 8 (04)
[14]   Moving From Clinic to Home: What the Future Holds for Ophthalmic Telemedicine [J].
Holekamp, Nancy M. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2018, 187 :XXVIII-XXXV
[15]  
Institute of Medicine, 1996, TEL GUID ASS TEL HLT
[16]   Validation of a computerised logMAR visual acuity measurement system (COMPlog): comparison with ETDRS and the electronic ETDRS testing algorithm in adults and amblyopic children [J].
Laidlaw, D. A. H. ;
Tailor, V. ;
Shah, N. ;
Atamian, S. ;
Harcourt, C. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (02) :241-244
[17]   Development of a clinically feasible logMAR alternative to the Snellen chart: performance of the ''compact reduced logMAR'' visual acuity chart in amblyopic children [J].
Laidlaw, DAH ;
Abbott, A ;
Rosser, DA .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (10) :1232-1234
[18]   Telemedicine distance and near visual acuity tests for adults and children [J].
Miller, Joseph M. ;
Jang, Hyun Soo ;
Ramesh, Divya ;
Gonzalez Marshall, Maria Sandra ;
Yescas, Selenne ;
Harvey, Erin M. .
JOURNAL OF AAPOS, 2020, 24 (04) :235-236
[19]   Optimising telemedicine in ophthalmology during the COVID-19 pandemic [J].
Patel, Shriji ;
Hamdan, Saif ;
Donahue, Sean .
JOURNAL OF TELEMEDICINE AND TELECARE, 2022, 28 (07) :498-501
[20]   POWER OF THE 2 ONE-SIDED TESTS PROCEDURE IN BIOEQUIVALENCE [J].
PHILLIPS, KF .
JOURNAL OF PHARMACOKINETICS AND BIOPHARMACEUTICS, 1990, 18 (02) :137-144