Three-dimensional fluid pressure mapping in porous media using magnetic resonance imaging with gas-filled liposomes

被引:8
作者
Morris, Robert H. [1 ]
Bencsik, Martin
Vangala, Anil K.
Perrie, Yvonne
机构
[1] Nottingham Trent Univ, Sch Biomed & Nat Sci, Nottingham NG11 8NS, England
[2] Aston Univ, Sch Life & Hlth Sci, Birmingham B4 7ET, W Midlands, England
基金
英国工程与自然科学研究理事会;
关键词
microbubble; porous medium; MRI; pressure; contrast agent; liposome;
D O I
10.1016/j.mri.2006.11.021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper presents and demonstrates a method for using magnetic resonance imaging to measure local pressure of a fluid saturating a porous medium. The method is tested both in a static system of packed silica gel and in saturated sintered glass cylinders experiencing fluid flow. The fluid used contains 3% gas in the form of 3-mu m average diameter gas filled 1,2-distearoyl-sn-glycero-3-phosphocholine (C18:0, MW: 790.16) liposomes suspended in 5% glycerol and 0.5% Methyl cellulose with water. Preliminary studies at 2.35 T demonstrate relative magnetic resonance signal changes of 20% per bar in bulk fluid for an echo time T-E=40 ins, and 6-10% in consolidated porous media for T-E=10 ms, over therange 0.8-1.8 bar for a spatial resolution of 0.1 mm(3) and a temporal resolution of 30 s. The stability of this solution with relation to applied pressure and methods for improving sensitivity are discussed. (C) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:509 / 512
页数:4
相关论文
共 7 条
[1]   Microbubbles as novel pressure-sensitive MR contrast agents [J].
Alexander, AL ;
McCreery, TT ;
Barrette, TR ;
Gmitro, AF ;
Unger, EC .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (06) :801-806
[2]   Direct measurement of porous media local hydrodynamical permeability using gas MRI [J].
Bencsik, M ;
Ramanathan, C .
MAGNETIC RESONANCE IMAGING, 2001, 19 (3-4) :379-383
[3]   CONDITIONS FOR INITIAL QUASI-LINEAR T(2)(-1) VERSUS TAU FOR CARR-PURCELL-MEIBOOM-GILL NMR WITH DIFFUSION AND SUSCEPTIBILITY DIFFERENCES IN POROUS-MEDIA AND TISSUES [J].
BROWN, RJS ;
FANTAZZINI, P .
PHYSICAL REVIEW B, 1993, 47 (22) :14823-14834
[4]   On the parameters affecting the sensitivity of MR measures of pressure with microbubbles [J].
Dharmakumar, R ;
Plewes, DB ;
Wright, GA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) :264-273
[5]   Targeted delivery of gas-filled microspheres, contrast agents for ultrasound imaging [J].
Klibanov, AL .
ADVANCED DRUG DELIVERY REVIEWS, 1999, 37 (1-3) :139-157
[6]  
UNGER EC, 1991, Patent No. 5205290
[7]   MICROSCOPIC SUSCEPTIBILITY VARIATION AND TRANSVERSE RELAXATION - THEORY AND EXPERIMENT [J].
WEISSKOFF, RM ;
ZUO, CS ;
BOXERMAN, JL ;
ROSEN, BR .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :601-610