Packing of the Cochleostomy Site Affects Auditory Nerve Response Thresholds in Precurved Off-Stylet Cochlear Implants

被引:12
作者
Gordin, Arie [1 ]
Papsin, Blake [1 ,2 ]
Gordon, Karen [2 ]
机构
[1] Hosp Sick Children, Dept Otolaryngol Head & Neck Surg, Toronto, ON M5G 1X8, Canada
[2] Hosp Sick Children, Cochlear Implant Lab, Toronto, ON M5G 1X8, Canada
关键词
Cochlear implants; Cochleostomy packing; Electrically evoked compound action potentials; ELECTRODE ARRAY; CHILDREN; CONTOUR; SPEECH; MENINGITIS; PLACEMENT; INSERTION; SAFETY; MODEL;
D O I
10.1097/MAO.0b013e3181ca8457
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives: To determine whether packing of the cochleostomy site influences electrically evoked compound action potential (ECAP) thresholds. Design: Prospective nonrandomized control study. Setting: Tertiary referral pediatric hospital. Patients: Eleven consecutive children who received unilateral or bilateral cochlear implants (16 Nucleus 24RE Freedom precurved advanced off-stylet electrode arrays [Cochlear Corp., Lane Cove, New South Wales, Australia]) between June and September 2008. Main Outcome Measures: Electrically evoked compound action potential thresholds were evoked by stimulation of basal (electrode 3), mid (electrode 9), and apical (electrode 20) electrodes during cochlear implant surgery in the operating room. The first recording was completed immediately after insertion of the electrode array before cochleostomy packing, and the same measures were collected immediately after the packing. The time between recordings was 5 minutes. Results: Electrically evoked compound action potential thresholds evoked by the apical electrode did not significantly change from pre- to post-cochleostomy packing, but ECAP thresholds increased significantly after packing when evoked by the mid-array electrode (mean, +10 clinical units; p < 0.001) and decreased significantly when evoked by the basal electrode (mean, -5.6 clinical units; p = 0.023). These changes were unrelated to passive changes occurring over the first 5 minutes after insertion of the electrode array. Conclusion: Packing of the cochleostomy causes changes in ECAP thresholds evoked by mid and basal areas of the implant electrode array. These findings suggest that packing shifts the electrode array in the cochlea, increasing the distance from the modiolus in the mid array and decreasing this distance at the basal end. This study is concerned with a single electrode array from a single manufacturer and a single insertion method (precurved off-stylet electrode). These conclusions may be too broad to apply to all precurved electrode arrays.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 22 条
[1]   Summary of results using the nucleus CI24M implant to record the electrically evoked compound action potential [J].
Abbas, PJ ;
Brown, CJ ;
Shallop, JK ;
Firszt, JB ;
Hughes, ML ;
Hong, SH ;
Staller, SJ .
EAR AND HEARING, 1999, 20 (01) :45-59
[2]   Prevention of meningitis - Cochlear implants and inner ear abnormalities [J].
Bluestone, CD .
ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2003, 129 (03) :279-281
[3]   The relationship between EAP and EABR thresholds and levels used to program the nucleus 24 speech processor: Data from adults [J].
Brown, CJ ;
Hughes, ML ;
Luk, B ;
Abbas, PJ ;
Wolaver, A ;
Gervais, J .
EAR AND HEARING, 2000, 21 (02) :151-163
[4]   Cochlear implants in children: safety as well as speech and language [J].
Clark, G .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2003, 67 :S7-S20
[5]   COCHLEAR IMPLANTATION IN CHILDREN - LABYRINTHITIS FOLLOWING PNEUMOCOCCAL OTITIS-MEDIA IN UNIMPLANTED AND IMPLANTED CAT COCHLEAS [J].
DAHM, MC ;
CLARK, GM ;
FRANZ, BKH ;
SHEPHERD, RK ;
BURTON, MJ ;
ROBINSBROWNE, R .
ACTA OTO-LARYNGOLOGICA, 1994, 114 (06) :620-625
[6]   The role of a graded profile analysis in determining candidacy and outcome for cochlear implantation in children [J].
Daya, H ;
Figueirido, JC ;
Gordon, KA ;
Twitchell, K ;
Gysin, C ;
Papsin, BC .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 1999, 49 (02) :135-142
[7]   Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes [J].
Finley, Charles C. ;
Holden, Timothy A. ;
Holden, Laura K. ;
Whiting, Bruce R. ;
Chole, Richard A. ;
Neely, Gail J. ;
Hullar, Timothy E. ;
Skinner, Margaret W. .
OTOLOGY & NEUROTOLOGY, 2008, 29 (07) :920-928
[8]   Electrically evoked auditory brain stem responses for lateral and medial placement of the Clarion HiFocus electrode [J].
Firszt, JB ;
Wackym, PA ;
Gaggl, W ;
Burg, LS ;
Reeder, RM .
EAR AND HEARING, 2003, 24 (02) :184-190
[9]   Spatial selectivity in a rotationally symmetric model of the electrically stimulated cochlea [J].
Frijns, JHM ;
deSnoo, SL ;
tenKate, JH .
HEARING RESEARCH, 1996, 95 (1-2) :33-48
[10]  
GORDIN A, 2009, OTOL NEUROTOL 0902