Coronary arterial stents: Safety and artifacts during MR imaging

被引:105
作者
Hug, J
Nagel, E
Bornstedt, A
Schnackenburg, B
Oswald, H
Fleck, E
机构
[1] Humboldt Univ, Charite, Dept Internal Med & Cardiol, D-13353 Berlin, Germany
[2] Philips Med Syst, Hamburg, Germany
关键词
coronary vessels; MR; stents and prostheses; magnetic resonance (MR); artifact; rapid imaging; safety;
D O I
10.1148/radiology.216.3.r00se03781
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate the safety and imaging artifacts with different coronary arterial stents and magnetic resonance (MR) imaging sequences. MATERIALS AND METHODS: The heating, artifacts, and ferromagnetism with different stents were studied with a 1.5-T MR tomograph with ultrafast gradients by using turbo spin-echo, turbo gradient-echo, and echo-planar imaging sequences. Nineteen stents, which were 8-25 mm in length and 3.0-4.5 mm in diameter, were evaluated. Stent deviation induced by the magnetic field and during MR imaging, migration, and heating caused by the radio-frequency pulses were examined. The size of imaging artifacts was measured with all the stents under standardized conditions and with six stents after their implantation into the coronary arteries of freshly explanted pig hearts. RESULTS: All except two types of stents showed minimal ferromagnetism. No device migration or heating was induced. Turbo spin-echo images had minimal artifacts; larger artifacts were seen on the turbo gradient-echo and echo-planar images. With ultrafast gradients, the artifacts on the echo-planar images were substantially reduced. CONCLUSION: The studied coronary stents were not influenced by heating or motion during 1.5-T MR imaging. Artifact size differed according to the type and size of the stent and the MR imaging sequence used. Thus, patients with these stents can be safely examined.
引用
收藏
页码:781 / 787
页数:7
相关论文
共 40 条
  • [1] MR IMAGING OF LARGE NONFERROMAGNETIC METALLIC IMPLANTS AT 1.5-T
    AUGUSTINY, N
    VONSCHULTHESS, GK
    MEIER, D
    BOSIGER, P
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (04) : 678 - 683
  • [2] BARRAFATO D, 1984, CAN J SURG, V27, P509
  • [3] MR ARTIFACTS - A REVIEW
    BELLON, EM
    HAACKE, EM
    COLEMAN, PE
    SACCO, DC
    STEIGER, DA
    GANGAROSA, RE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (06) : 1271 - 1281
  • [4] SHUNTS FOR PORTAL-HYPERTENSION - MR AND ANGIOGRAPHY FOR DETERMINATION OF PATENCY
    BERNARDINO, ME
    STEINBERG, HV
    PEARSON, TC
    GEDGAUDASMCCLEES, RK
    TORRES, WE
    HENDERSON, JM
    [J]. RADIOLOGY, 1986, 158 (01) : 57 - 61
  • [5] POTENTIAL HAZARDS IN NMR IMAGING - HEATING EFFECTS OF CHANGING MAGNETIC-FIELDS AND RF FIELDS ON SMALL METALLIC IMPLANTS
    DAVIS, PL
    CROOKS, L
    ARAKAWA, M
    MCREE, R
    KAUFMAN, L
    MARGULIS, AR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (04) : 857 - 860
  • [6] ENDOVASCULAR STENTS - PRELIMINARY CLINICAL-RESULTS AND FUTURE-DEVELOPMENTS
    DEJAEGERE, PPT
    DEFEYTER, PJ
    VANDERGIESSEN, WJ
    SERRUYS, PW
    [J]. CLINICAL CARDIOLOGY, 1993, 16 (05) : 369 - 378
  • [7] ANEURYSM CLIP MOTION DURING MAGNETIC-RESONANCE IMAGING - INVIVO EXPERIMENTAL-STUDY WITH METALLURGICAL FACTOR-ANALYSIS
    DUJOVNY, M
    KOSSOVSKY, N
    KOSSOWSKY, R
    VALDIVIA, R
    SUK, JS
    DIAZ, FG
    BERMAN, SK
    CLEARY, W
    [J]. NEUROSURGERY, 1985, 17 (04) : 543 - 548
  • [8] FAGAN LL, 1995, JMRI-J MAGN RESON IM, V5, P614
  • [9] Coronary arteries: Breath-hold, gadolinium-enhanced, three-dimensional MR angiography
    Goldfarb, JW
    Edelman, RR
    [J]. RADIOLOGY, 1998, 206 (03) : 830 - 834
  • [10] HASSLER M, 1986, Journal de Radiologie (Paris), V67, P661