Three-dimensional quantitative analysis of polymer foams from synchrotron radiation x-ray microtomography

被引:48
作者
Elmoutaouakkil, A
Fuchs, G
Bergounhon, P
Péres, R
Peyrin, F
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[2] Ctr Rech Rhone Alpes, ATOFINA, F-69493 Pierre Benite, France
[3] ATOFINA, Lab Appl Plast, St Auban Sur Durance, France
关键词
D O I
10.1088/0022-3727/36/10A/308
中图分类号
O59 [应用物理学];
学科分类号
摘要
We propose a three-dimensional and high-resolution quantitative image analysis technique for the investigation of the internal microstructure of polymer foams. Microscopy, which is the conventional method of investigation of foams, images only the surface of samples, though, three-dimensional x-ray computed microtomography (muCT) enables the non-destructive imaging of multiple slices of a sample. It is a powerful technique for the examination of porous and multiphase materials. In this paper, we present the application of three-dimensional synchrotron radiation muCT for the characterization of foam samples. After a brief description of the imaging system, we present three-dimensional image-processing tools developed to extract structural parameters quantifying the internal structure of foams. Results of this three-dimensional quantitative image analysis on various types of plasticized poly vinyl chloride foams are presented. This approach provides a tool to study the relationships between the foam microstructures and their physical properties.
引用
收藏
页码:A37 / A43
页数:7
相关论文
共 20 条
[11]   Cell morphology and property relationships of microcellular foamed PVC/wood-fiber composites [J].
Matuana, LM ;
Park, CB ;
Balatinecz, JJ .
POLYMER ENGINEERING AND SCIENCE, 1998, 38 (11) :1862-1872
[12]   HIGH-ENERGY HIGH-RESOLUTION MONOCHROMATIC X-RAY COMPUTED-TOMOGRAPHY USING THE PHOTON FACTORY VERTICAL WIGGLER BEAMLINE [J].
NAGATA, Y ;
YAMAJI, H ;
HAYASHI, K ;
KAWASHIMA, K ;
HYODO, K ;
KAWATA, H ;
ANDO, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :615-618
[13]  
Neff R, 1998, J POLYM SCI POL PHYS, V36, P573, DOI 10.1002/(SICI)1099-0488(199803)36:4<573::AID-POLB4>3.0.CO
[14]  
2-Q
[15]  
PROVDER T, 1998, PARTICLE SIZE DISTRI, V3
[16]   A synchrotron radiation microtomography system for the analysis of trabecular bone samples [J].
Salomé, M ;
Peyrin, F ;
Cloetens, P ;
Odet, C ;
Laval-Jeantet, AM ;
Baruchel, J ;
Spanne, P .
MEDICAL PHYSICS, 1999, 26 (10) :2194-2204
[17]   Method-based differences in the automated analysis of the three-dimensional morphology of trabecular bone [J].
Simmons, CA ;
Hipp, JA .
JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (06) :942-947
[18]   X-ray computed tomography on a cellular polysiloxane under compression [J].
Smith, RA ;
Paulus, MJ ;
Branning, JM ;
Phillips, PJ .
JOURNAL OF CELLULAR PLASTICS, 2001, 37 (03) :231-248
[19]   COMPUTERIZED MICROTOMOGRAPHY USING SYNCHROTRON RADIATION FROM THE NSLS [J].
SPANNE, P ;
RIVERS, ML .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 24-5 :1063-1067
[20]  
Wilson A. J., 1989, FOAMS PHYSICS CHEM S, P233