Dose recalculation in megavoltage cone-beam CT for treatment evaluation: Removal of cupping and truncation artefacts in scans of the thorax and abdomen

被引:15
作者
Petit, Steven F. [1 ]
van Elmpt, Wouter J. C. [1 ]
Lambin, Philippe [1 ]
Dekker, Andre L. A. J. [1 ]
机构
[1] MUMC, Dept Radiat Oncol, MAASTRO Clin, GROW Sch Oncol & Dev Biol, NL-6201 BN Maastricht, Netherlands
关键词
Megavoltage cone-beam CT (MVCBCT); Cupping artefacts; Truncation artifacts; Dose recalculation; Dose reconstruction; Treatment evaluation; GUIDED RADIATION-THERAPY; RADIOTHERAPY; VERIFICATION; DOSIMETRY; SCATTER; CANCER; IMAGES;
D O I
10.1016/j.radonc.2009.12.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To correct megavoltage cone-beam CT (MVCBCT) images of the thorax and abdomen for cupping and truncation artefacts to reconstruct the 3D-delivered dose distribution for treatment evaluation. Materials and methods: MVCBCT scans of three phantoms, three lung and two rectal cancer patients were acquired. The cone-beam projection images were iteratively corrected for cupping and truncation artefacts and the resulting primary transmission was used for cone-beam reconstruction. The reconstructed scans were merged into the planning CT scan (MVCBCT+). Dose distributions of clinical IMRT, stereotactic and conformal treatment plans were recalculated on the uncorrected and corrected MVCBCT+ scans using the treatment planning system and compared to the planned dose distribution. Results: The dose distributions on the corrected MVCBCT+ of the phantoms were accurate for 99% of the voxels within 2% or 2 mm. Using this method the errors in mean GTV dose reduced from about 10% to 1% for the patients. Conclusions: The method corrects cupping and truncation artefacts in cone-beam scans of the thorax and abdomen in addition to head-and-neck (demonstrated previously). The corrected scans can be used to calculate the influence of anatomical changes on the 3D-delivered dose distribution. (C) 2009 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 94 (2010) 359-366
引用
收藏
页码:359 / 366
页数:8
相关论文
共 25 条
[1]   Correction of megavoltage cone-beam CT images of the pelvic region based on phantom measurements for dose calculation purposes [J].
Aubry, Jeanm Francois ;
Cheung, Joey ;
Morin, Olivier ;
Gottschalk, Alexander ;
Beaulieu, Luc ;
Pouliot, Jean .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (01) :33-42
[2]   Correction of megavoltage cone-beam CT images for dose calculation in the head and neck region [J].
Aubrya, Jean-Francois ;
Pouliot, Jean ;
Beaulieu, Luc .
MEDICAL PHYSICS, 2008, 35 (03) :900-907
[3]   Dose-guided radiation therapy with megavoltage cone-beam CT [J].
Chen, J. ;
Morin, O. ;
Aubin, M. ;
Bucci, M. K. ;
Chuang, C. F. ;
Pouliot, J. .
BRITISH JOURNAL OF RADIOLOGY, 2006, 79 :S87-S98
[4]   DOSE RECALCULATION AND THE DOSE-GUIDED RADIATION THERAPY (DGRT) PROCESS USING MEGAVOLTAGE CONE-BEAM CT [J].
Cheung, Joey ;
Aubry, Jean-Francois ;
Yom, Sue S. ;
Gottschalk, Alexander R. ;
Celi, Juan Carlos ;
Pouliot, Jean .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (02) :583-592
[5]   Advances in image-guided radiation therapy [J].
Dawson, Laura A. ;
Jaffray, David A. .
JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (08) :938-946
[6]   Cone-beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device: Potential for verification of radiotherapy of lung cancer [J].
Ford, EC ;
Chang, J ;
Mueller, K ;
Sidhu, K ;
Todor, D ;
Mageras, G ;
Yorke, E ;
Ling, CC ;
Amols, H .
MEDICAL PHYSICS, 2002, 29 (12) :2913-2924
[7]   Commissioning and clinical implementation of a mega-voltage cone beam CT system for treatment localization [J].
Gayou, Olivier ;
Miften, Moyed .
MEDICAL PHYSICS, 2007, 34 (08) :3183-3192
[8]   The application of transit dosimetry to precision radiotherapy [J].
Hansen, VN ;
Evans, PM ;
Swindell, W .
MEDICAL PHYSICS, 1996, 23 (05) :713-721
[9]   The use of megavoltage CT (MVCT) images for dose recomputations [J].
Langen, KM ;
Meeks, SL ;
Poole, DO ;
Wagner, TH ;
Willoughby, TR ;
Kupelian, PA ;
Ruchala, KJ ;
Haimerl, J ;
Olivera, GH .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (18) :4259-4276
[10]   Algorithm for X-ray Scatter, Beam-Hardening, and Beam Profile Correction in Diagnostic (Kilovoltage) and Treatment (Megavoltage) Cone Beam CT [J].
Maltz, Jonathan S. ;
Gangadharan, Bijumon ;
Bose, Supratik ;
Hristov, Dimitre H. ;
Faddegon, Bruce A. ;
Paidi, Ajay ;
Bani-Hashemi, Ali R. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (12) :1791-1810