Direct neural current imaging in an intact cerebellum with magnetic resonance imaging

被引:21
|
作者
Sundarama, Padmavathi [1 ,2 ]
Nummenmaa, Aapo [2 ]
Wells, William [3 ]
Orbach, Darren [1 ]
Orringer, Daniel [4 ,6 ]
Mulkern, Robert [1 ]
Okada, Yoshio [5 ]
机构
[1] Harvard Univ, Sch Med, Dept Radiol, Boston Childrens Hosp, Boston, MA 02115 USA
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Athinoula A Martinos Ctr Biomed Imaging,Dept Radi, Charlestown, MA 02129 USA
[3] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Radiol, Boston, MA 02115 USA
[4] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Neurosurg, Boston, MA 02115 USA
[5] Harvard Univ, Sch Med, Boston Childrens Hosp, Dept Newborn Med, Boston, MA 02215 USA
[6] Univ Michigan, Dept Neurosurg, Ann Arbor, MI 48109 USA
基金
美国国家科学基金会;
关键词
NEURONAL CURRENT MRI; HUMAN OPTIC-NERVE; ULTRA-LOW FIELD; TURTLE CEREBELLUM; HUMAN BRAIN; PURKINJE-CELLS; SYNAPTIC TRANSMISSION; PHYSIOLOGICAL NOISE; VISUAL-STIMULATION; SIGNAL MODULATION;
D O I
10.1016/j.neuroimage.2016.01.059
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The ability to detect neuronal currents with high spatiotemporal resolution using magnetic resonance imaging (MRI) is important for studying human brain function in both health and disease. While significant progress has been made, we still lack evidence showing that it is possible to measure an MR signal time-locked to neuronal currents with a temporal waveform matching concurrently recorded local field potentials (LFPs). Also lacking is evidence that such MR data can be used to image current distribution in active tissue. Since these two results are lacking even in vitro, we obtained these data in an intact isolated whole cerebellum of turtle during slow neuronal activity mediated by metabotropic glutamate receptors using a gradient-echo EPI sequence (TR = 100 ms) at 4.7 T. Our results show that it is possible (1) to reliably detect an MR phase shift time course matching that of the concurrently measured LFP evoked by stimulation of a cerebellar peduncle, (2) to detect the signal in single voxels of 0.1 mm(3), (3) to determine the spatial phase map matching the magnetic field distribution predicted by the LFP map, (4) to estimate the distribution of neuronal current in the active tissue from a group-average phase map, and (5) to provide a quantitatively accurate theoretical account of the measured phase shifts. The peak values of the detected MR phase shifts were 0.27-0.37 degrees, corresponding to local magnetic field changes of 0.67-0.93 nT (for TE = 26 ms). Our work provides an empirical basis for future extensions to in vivo imaging of neuronal currents. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:477 / 490
页数:14
相关论文
共 50 条
  • [1] The stray magnetic fields in Magnetic Resonance Current Density Imaging (MRCDI)
    Goksu, Cihan
    Scheffler, Klaus
    Siebner, Hartwig R.
    Thielscher, Axel
    Hanson, Lars G.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 59 : 142 - 150
  • [2] Quantitative perfusion imaging in magnetic resonance imaging
    Zoellner, F. G.
    Gaa, T.
    Zimmer, F.
    Ong, M. M.
    Riffel, P.
    Hausmann, D.
    Schoenberg, S. O.
    Weis, M.
    RADIOLOGE, 2016, 56 (02): : 113 - 123
  • [3] Magnetic resonance imaging of oscillating electrical currents
    Halpern-Manners, Nicholas W.
    Bajaj, Vikram S.
    Teisseyre, Thomas Z.
    Pines, Alexander
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2010, 107 (19) : 8519 - 8524
  • [4] Magnetic resonance imaging of glutamate
    Cai, Kejia
    Haris, Mohammad
    Singh, Anup
    Kogan, Feliks
    Greenberg, Joel H.
    Hariharan, Hari
    Detre, John A.
    Reddy, Ravinder
    NATURE MEDICINE, 2012, 18 (02) : 302 - 306
  • [5] Exploration of the Neural Correlates of Ticklish Laughter by Functional Magnetic Resonance Imaging
    Wattendorf, Elise
    Westermann, Birgit
    Fiedler, Klaus
    Kaza, Evangelia
    Lotze, Martin
    Celio, Marco R.
    CEREBRAL CORTEX, 2013, 23 (06) : 1280 - 1289
  • [6] Magnetic Resonance Imaging of Ionic Currents in Solution: The Effect of Magnetohydrodynamic Flow
    Balasubramanian, Mukund
    Mulkern, Robert V.
    Wells, William M.
    Sundaram, Padmavathi
    Orbach, Darren B.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (04) : 1145 - 1155
  • [7] Direct magnetic resonance imaging of histological tissue samples at 3.0T
    Meadowcroft, Mark D.
    Zhang, Shutong
    Liu, Wanzhan
    Park, Bu Sik
    Connor, James R.
    Collins, Christopher M.
    Smith, Michael B.
    Yang, Qing X.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (05) : 835 - 841
  • [8] Neural Substrates for Head Movements in Humans: A Functional Magnetic Resonance Imaging Studye
    Prudente, Cecilia N.
    Stilla, Randall
    Buetefisch, Cathrin M.
    Singh, Shivangi
    Hess, Ellen J.
    Hu, Xiaoping
    Sathian, Krish
    Jinnah, H. A.
    JOURNAL OF NEUROSCIENCE, 2015, 35 (24) : 9163 - 9172
  • [10] Computational neuroanatomy and microstructure imaging using magnetic resonance imaging
    Mohammadi, S.
    Weiskopf, N.
    NERVENARZT, 2017, 88 (08): : 839 - 849