Finite Element Modeling of Corneal Biomechanical Behavior

被引:56
作者
Elsheikh, Ahmed [1 ]
机构
[1] Univ Dundee, Div Civil Engn, Dundee DD1 4HN, Scotland
关键词
COLLAGEN FIBRILS; THICKNESS; STRENGTH; ORGANIZATION; ORIENTATION; TOPOGRAPHY;
D O I
10.3928/1081597X-20090710-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To optimize the construction details of corneal numerical models while maintaining efficiency and reliability of predictions. METHODS: Nonlinear finite element analysis of corneal models was carried out to assess the importance of considering the cornea's hyperelastic, hysteretic and anisotropic behavior, multi-layer construction, weak inter-lamellar adhesion, non-uniform thickness, elliptical topography, and connection to the sclera. The effect of each of these parameters was determined by removing it from the numerical models and assessing the effect on the results. This exercise was carried out under two load cases a uniform posterior pressure subjecting the cornea to predominantly membrane tension stresses, and a concentrated anterior pressure as applied by the Ocular Response Analyzer (Reichert Ophthalmic Instruments), which creates mainly bending stresses. RESULTS: Corneal models subjected to mainly bending stresses were particularly sensitive to simplifications in modeling corneal nonuniform thickness, weak interlamellar adhesion, and multi-layer construction. On the other hand, models under mainly membrane tension were more sensitive to simplifications in elliptical profile and connection to the sclera. Considering hyper-elasticity was important in both cases. Hysteresis was also important, but only in applications involving load reversal. CONCLUSIONS: Although simplifications may be necessary to reduce the cost of numerical model construction and analysis, the selection of which simplifications to adopt should be done with care. They should only be considered when their effect on results is acceptably small, and their inclusion does not make the model significantly different from real-life conditions. [J Refract Surg. 2010;26:289-300.] doi:10.3928/1081597X-20090710-01
引用
收藏
页码:289 / 300
页数:12
相关论文
共 45 条
[1]   Central corneal thickness of Caucasians, Chinese, Hispanics, Filipinos, African Americans, and Japanese in a glaucoma clinic [J].
Aghaian, E ;
Choe, JE ;
Lin, S ;
Stamper, RL .
OPHTHALMOLOGY, 2004, 111 (12) :2211-2219
[2]   X-ray scattering used to map the preferred collagen orientation in the human cornea and limbus [J].
Aghamohammadzadeh, H ;
Newton, RH ;
Meek, KM .
STRUCTURE, 2004, 12 (02) :249-256
[3]   Biomechanical modeling of refractive corneal surgery [J].
Alastrué, V ;
Calvo, B ;
Peña, E ;
Doblaré, M .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (01) :150-160
[4]   Application of structural analysis to the mechanical behaviour of the cornea [J].
Anderson, K ;
El-Sheikh, A ;
Newson, T .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2004, 1 (01) :3-15
[5]  
[Anonymous], 2000, FINITE ELEMENT METHO
[6]   MODELING REQUIREMENTS FOR FINITE-ELEMENT ANALYSIS [J].
ARMSTRONG, CG .
COMPUTER-AIDED DESIGN, 1994, 26 (07) :573-578
[7]  
BABUUSKA I, 2001, FINITE ELEMENT METHO
[8]   Lamellar orientation in human cornea in relation to mechanical properties [J].
Boote, C ;
Dennis, S ;
Huang, YF ;
Quantock, AJ ;
Meek, KM .
JOURNAL OF STRUCTURAL BIOLOGY, 2005, 149 (01) :1-6
[9]   Stress-controlled viscoelastic tensile response of bovine cornea [J].
Boyce, B. L. ;
Jones, R. E. ;
Nguyen, T. D. ;
Grazier, J. M. .
JOURNAL OF BIOMECHANICS, 2007, 40 (11) :2367-2376
[10]   Constitutive laws for biomechanical modeling of refractive surgery [J].
Bryant, MR ;
McDonnell, PJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (04) :473-481