Incidence and characteristics of failures in obstetric neuraxial analgesia and anesthesia: A retrospective analysis of 19,259 deliveries

被引:241
作者
Pan, PH [1 ]
Bogard, TD [1 ]
Owen, MD [1 ]
机构
[1] Wake Forest Univ, Sch Med, Dept Anesthesiol, Div Obstet Anesthesia, Winston Salem, NC 27157 USA
关键词
obstetric; epidural; spinal; combined spinal-epidural; failures; complications; neuraxial analgesia;
D O I
10.1016/j.ijoa.2004.04.008
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A retrospective analysis was performed on 19,259 deliveries that occurred in our institution from January 2000 to December 2002. Anesthesia records and quality assurance data sheets were reviewed for the characteristics and failure rates of neuraxial blocks performed for labor analgesia and anesthesia. The neuraxial labor analgesia rate was 75% and the overall failure rate was 12%. After adequate analgesia from initial placement, 6.8% of patients had subsequent inadequate analgesia during labor that required epidural catheter replacement. Ultimately 98.8% of all patients received adequate analgesia even though 1.5% of patients had multiple replacements. Six percent of epidural catheters had initial intravenous placement but 46% were made functional by simple manipulations without higher subsequent failure. Unintended dural puncture occurred in 1.2% of labor neuraxial analgesia. The incidences of overall failure, intravenous epidural catheter, wet tap, inadequate epidural analgesia and catheter replacement were lower in patients receiving combined spinal-epidural versus epidural analgesia. For cesarean section, 7.1% of pre-existing labor epidural catheters failed and 4.3% of patients required conversion to general anesthesia. Spinal anesthesia for cesarean section had a lower failure rate of 2.7%, with 1.2% of the patients requiring general anesthesia. The overall use of general anesthesia decreased from 8% to 4.3% over the three-year period. Furthermore, regional anesthesia was used in 93.5% of cesarean deliveries with no anesthetic-related mortalities. Future investigations should identify acceptable international standards, risk factors associated with failure and methods to reduce failure before cesarean section. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:227 / 233
页数:7
相关论文
共 19 条
[1]   FAILED EXTRADURAL ANESTHESIA FOR CESAREAN-SECTION - COMPLICATION OF SUBSEQUENT SPINAL-BLOCK [J].
BECK, GN ;
GRIFFITHS, AG .
ANAESTHESIA, 1992, 47 (08) :690-692
[2]   Quality of analgesia when air versus saline is used for identification of the epidural space in the parturient [J].
Beilin, Y ;
Arnold, I ;
Telfeyan, C ;
Bernstein, HH ;
Hossain, S .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2000, 25 (06) :596-599
[3]  
BEILIN Y, 1995, ANESTH ANALG, V81, P301
[4]   SECOND THOUSAND EPIDURAL BLOCKS IN AN OBSTETRIC HOSPITAL PRACTICE [J].
CRAWFORD, JS .
BRITISH JOURNAL OF ANAESTHESIA, 1972, 44 (12) :1277-1286
[5]   Prospective examination of epidural catheter insertion [J].
DAngelo, R ;
Berkebile, BL ;
Gerancher, JC .
ANESTHESIOLOGY, 1996, 84 (01) :88-93
[6]   A comparison of multiport and uniport epidural catheters in laboring patients [J].
DAngelo, R ;
Foss, ML ;
Livesay, CH .
ANESTHESIA AND ANALGESIA, 1997, 84 (06) :1276-1279
[7]   Incidence of epidural catheter replacement in parturients: A retrospective chart review [J].
Eappen, S ;
Blinn, A ;
Segal, S .
INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 1998, 7 (04) :220-225
[8]   Failure of regional blockade for caesarean section [J].
Garry, M ;
Davies, S .
INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2002, 11 (01) :9-12
[9]   Anesthesia-related deaths during obstetric delivery in the United States, 1979-1990 [J].
Hawkins, JL ;
Koonin, LM ;
Palmer, SK ;
Gibbs, CP .
ANESTHESIOLOGY, 1997, 86 (02) :277-284
[10]   ANESTHETIC AND OBSTETRIC OUTCOME IN MORBIDLY OBESE PARTURIENTS [J].
HOOD, DD ;
DEWAN, DM .
ANESTHESIOLOGY, 1993, 79 (06) :1210-1218