Reduction of metal streak artifacts in x-ray computed tomography using a transmission maximum a posteriori algorithm

被引:184
作者
De Man, B [1 ]
Nuyts, J
Dupont, P
Marchal, G
Suetens, P
机构
[1] Katholieke Univ Leuven, PSI, ESAT, GHB,UZ, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, GHB, UZ, Dept Nucl Med, B-3000 Louvain, Belgium
[3] Katholieke Univ Leuven, GHB, UZ, Dept Radiol, B-3000 Louvain, Belgium
关键词
D O I
10.1109/23.856534
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A maximum a posteriori algorithm for reduction of metal streak artifacts in x-ray computed tomography is presented. The algorithm uses a Markov random field smoothness prior and applies increased sampling in the reconstructed image. Good results are obtained for simulations and phantom measurements: streak artifacts are reduced while small, line-shaped details are preserved.
引用
收藏
页码:977 / 981
页数:5
相关论文
共 24 条
  • [11] Bayesian reconstruction of PET images: Methodology and performance analysis
    Mumcuoglu, EU
    Leahy, RM
    Cherry, SR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (09) : 1777 - 1807
  • [12] Iterative reconstruction for helical CT: a simulation study
    Nuyts, J
    De Man, B
    Dupont, P
    Defrise, M
    Suetens, P
    Mortelmans, L
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) : 729 - 737
  • [13] Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms
    Nuyts, J
    Dupont, P
    Stroobants, S
    Benninck, R
    Mortelmans, L
    Suetens, P
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (05) : 393 - 403
  • [14] NUYTS J, 1997, 2 IEEE WORKSH CMP CA, P237
  • [15] Oppenheim B.E., 1977, RECONSTRUCTION TOMOG, P155
  • [16] RAJGOPAL K, 1997, MED IMAGING SYSTEMS, P281
  • [17] Robertson D D, 1989, J Arthroplasty, V4, P271, DOI 10.1016/S0883-5403(89)80024-5
  • [18] EVALUATION OF CT TECHNIQUES FOR REDUCING ARTIFACTS IN THE PRESENCE OF METALLIC ORTHOPEDIC IMPLANTS
    ROBERTSON, DD
    WEISS, PJ
    FISHMAN, EK
    MAGID, D
    WALKER, PS
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (02) : 236 - 241
  • [19] Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction
    Robertson, DD
    Yuan, J
    Wang, G
    Vannier, MW
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (02) : 293 - 298
  • [20] CT BONE DENSITOMETRY OF THE ANCHORAGE OF ARTIFICIAL KNEE JOINTS
    SEITZ, P
    RUEGSEGGER, P
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (03) : 621 - 622