A 3-DIMENSIONAL ACCURACY ANALYSIS OF CHAIRSIDE CAD/CAM MILLING PROCESSES

被引:117
作者
Bosch, Gabriel [1 ]
Ender, Andreas [1 ]
Mehl, Albert [1 ]
机构
[1] Univ Zurich, Ctr Dent Med, Div Computerized Restorat Dent, CH-8032 Zurich, Switzerland
关键词
CERAMIC CROWN SYSTEMS; IN-VITRO; INTERNAL FIT; MARGINAL FIT; FIRING CYCLES; RESTORATIONS; COPINGS; ADAPTATION; DESIGN; INLAYS;
D O I
10.1016/j.prosdent.2014.05.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Milling is a central and important aspect of computer-aided design and computer-aided manufacturing (CAD/CAM) technology. High milling accuracy reduces the time needed to adapt the workpiece and provides restorations with better longevity and esthetic appeal. The influence of different milling processes on the accuracy of milled restorations has not yet been reviewed. Purpose. The purpose of this study was to investigate the influence of different milling processes on the accuracy of ceramic restorations. Material and methods. Four groups of partial crowns were milled (each n=17): Three groups in a 4-axial milling unit: (1) 1-step mode and Step Bur 125 (125), (2) 1-step mode and Step Bur 12 (1Step), (3) 2-step mode and Step Bur 12 (2Step), and (4) one group in a 5-axial milling unit (5axis). The milled occlusal and inner surfaces were scanned and superimposed over the digital data sets of calculated restorations with specialized difference analysis software. The trueness of each restoration and each group was measured. One-way ANOVA with a post hoc Tukey test was used to compare the data (alpha=.05). Results. The highest trueness for the inner surface was achieved in group 5axis (trueness, 41 +/- 15 mu m, P<.05). The 4-axial milling unit exhibited trueness at settings ranging from 61 mu m (2Step) to 96 mu m (12S). For the occlusal surface, the highest trueness was achieved with group 5axis (trueness, 42 +/- 10 mu m). The 4-axial milling unit exhibited trueness at settings ranging from 55 mu m (1Step) to 76 mu m (12S). Conclusions. Restorations milled with a 5-axial milling unit have a higher trueness than those milled with a 4-axial milling unit. A rotary cutting instrument with a smaller diameter results in a more accurate milling process. The 2-step mode is not significantly better than the 1-step mode.
引用
收藏
页码:1425 / 1431
页数:7
相关论文
共 40 条
  • [1] Interface gap size of manually and CAD/CAM-manufactured ceramic inlays/onlays in vitro
    Addi, S
    Hedayati-Khams, A
    Poya, A
    Sjögren, G
    [J]. JOURNAL OF DENTISTRY, 2002, 30 (01) : 53 - 58
  • [2] FACTORS AFFECTING THE FIT OF PORCELAIN JACKET CROWNS
    ALKUMRU, H
    HULLAH, WR
    MARQUIS, PM
    WILSON, HJ
    [J]. BRITISH DENTAL JOURNAL, 1988, 164 (02) : 39 - 43
  • [3] Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems
    Balkaya, MC
    Cinar, A
    Pamuk, S
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (04) : 346 - 355
  • [4] Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations
    Bindl, A
    Mörmann, WH
    [J]. JOURNAL OF ORAL REHABILITATION, 2005, 32 (06) : 441 - 447
  • [5] Clinical and SEM evaluation of all-ceramic chair-side CAD/CAM-generated partial crowns
    Bindl, A
    Mörmann, WH
    [J]. EUROPEAN JOURNAL OF ORAL SCIENCES, 2003, 111 (02) : 163 - 169
  • [6] Clinical fit of Procera AllCeram crowns
    Boening, KW
    Wolf, BH
    Schmidt, AE
    Kästner, K
    Walter, MH
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (04) : 419 - 424
  • [7] The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems
    Brawek, Petya K.
    Wolfart, Stefan
    Endres, Lutz
    Kirsten, Armin
    Reich, Sven
    [J]. CLINICAL ORAL INVESTIGATIONS, 2013, 17 (09) : 2119 - 2125
  • [8] Ender A, 2013, INT J COMPUT DENT, V16, P11
  • [9] Ender A, 2011, Int J Comput Dent, V14, P11
  • [10] Marginal adaptation of zirconium dioxide copings: Influence of the CAD/CAM system and the finish line design
    Euan, Raul
    Figueras-Alvarez, Oscar
    Cabratosa-Termes, Josep
    Oliver-Parra, Rogelio
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (02) : 155 - 162