Haemodynamic effects of patent foramen ovale and atrial septal defect closure: a comparison during percutaneous shunt closure

被引:4
|
作者
Luermans, Justin G. L. M. [1 ]
Bos, Willem J. W. [2 ]
Post, Martijn C. [1 ]
ten Berg, Jurrien M. [1 ]
Plokker, H. W. Thijs [1 ]
Suttorp, Maarten J. [1 ]
机构
[1] St Antonius Hosp, Dept Cardiol, NL-3435 CM Nieuwegein, Netherlands
[2] St Antonius Hosp, Dept Internal Med, NL-3435 CM Nieuwegein, Netherlands
关键词
atrial septal defect; Finometer; haemodynamics; patent foramen ovale; transcatheter closure; TRANSCATHETER CLOSURE; ARTERIAL-PRESSURE; FINGER; HUMANS; FLOW;
D O I
10.1111/j.1475-097X.2009.00905.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
P>Objectives: We investigated the haemodynamic effect of percutaneous closure of an intra-atrial shunt, using non-invasive finger pressure measurements. Background: Percutaneous closure of both patent foramen ovale (PFO) and atrial septal defect (ASD) is widely practised. Currently no data are available on short-term haemodynamic changes induced by closure. Methods: Twenty-five consecutive patients (mean age 49 +/- 17 years, 10 men) who underwent a percutaneous closure of a PFO (n = 15) or ASD (n = 10) were included in this study. During the procedure blood pressure and heart rate (HR) were monitored continuously with a Finometer (R). Changes in systolic, mean, and diastolic pressure, stroke volume (SV), cardiac output (CO) and total peripheral resistance (TPR) were computed from the pressure registrations using Modelflow (R) methodology. Results: Baseline characteristics were similar for the PFO and ASD patients. After PFO closure none of the haemodynamic parameters changed significantly. After ASD closure the systolic, mean, and diastolic pressures increased 7 center dot 1 +/- 5 center dot 4 (P = 0 center dot 003), 3 center dot 8 +/- 3 center dot 5 (P = 0 center dot 007) and 2 center dot 0 +/- 3 center dot 0 mmHg (P = ns) respectively. HR decreased 5 center dot 1 +/- 5 center dot 3 beats per minute (P = 0 center dot 01). SV, CO and TPR increased 8 center dot 5 +/- 6 center dot 4 ml (13 center dot 5%; P = 0 center dot 002), 0 center dot 21 +/- 0 center dot 45 l min-1 (5 center dot 6%; P = ns) and 0 center dot 02 +/- 0 center dot 14 dynes (4 center dot 1%; P = ns) respectively. The changes in SV differ between the PFO and ASD patients (P = 0 center dot 009). Conclusions: Using non-invasive finger pressure measurements, we found that SV, mean and systolic blood pressure increased immediately after percutaneous closure of an ASD in adults, whereas the percutaneous PFO closure had no effect on haemodynamic characteristics.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 50 条
  • [21] Second transcatheter closure for residual shunt following percutaneous closure of patent foramen ovale
    Susuri, Njomeza
    Obeid, Slayman
    Ulmi, Mirjam
    Siontis, George C. M.
    Wahl, Andreas
    Windecker, Stephan
    Nietlispach, Fabian
    Meier, Bernhard
    Praz, Fabien
    EUROINTERVENTION, 2017, 13 (07) : 858 - 866
  • [22] Antiplatelet and Antithrombotic Therapy After Patent Foramen Oval and Atrial Septal Defect Closure
    Drakopoulou, Maria
    Soulaidopoulos, Stergios
    Stathogiannis, Konstantinos
    Oikonomou, Georgios
    Papanikolaou, Aggelos
    Toutouzas, Konstantinos
    Tousoulis, Dimitrios
    CURRENT PHARMACEUTICAL DESIGN, 2020, 26 (23) : 2769 - 2779
  • [23] Transcatheter Closure of Patent Foramen Ovale in A Patient with Aneurysmal Atrial Septum and Multifenestrated Atrial Septal Defect
    Khajali, Zahra
    Firouzi, Ata
    Nazari, Mohamad Sadra
    Hedayati, Maryam Keshavarz
    Jorfi, Fateme
    Alizadehasl, Azin
    Zohrian, Fatemeh
    INTERNATIONAL CARDIOVASCULAR RESEARCH JOURNAL, 2020, 14 (04) : 157 - 160
  • [24] A Comparison Between Gore Cardioform and Amplatzer Septal Occluder for Percutaneous Closure of Patent Foramen Ovale Associated With Atrial Septal Aneurysm: Clinical and Echocardiographic Outcomes
    Musto, Carmine
    Cifarelli, Alberta
    Dipasquale, Francesco
    Chin, Diana
    Nazzaro, Marco Stefano
    Stio, Rocco Edoardo
    Pennacchi, Mauro
    De Felice, Francesco
    JOURNAL OF INVASIVE CARDIOLOGY, 2021, 33 (11) : E857 - E862
  • [25] Impact of the antiplatelet strategy following patent foramen ovale percutaneous closure
    Guedeney, Paul
    Farjat-Pasos, Julio, I
    Asslo, Gabriel
    Roule, Vincent
    Beygui, Farzin
    Hermida, Alexis
    Gabrion, Paul
    Leborgne, Laurent
    Houde, Christine
    Huang, Florent
    Lattuca, Benoit
    Leclercq, Florence
    Mesnier, Jules
    Abtan, Jeremie
    Rouanet, Stephanie
    Hammoudi, Nadjib
    Collet, Jean-Philippe
    Zeitouni, Michel
    Silvain, Johanne
    Montalescot, Gilles
    Rodes-Cabau, Josep
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR PHARMACOTHERAPY, 2023, 9 (07) : 601 - 607
  • [26] Results of Percutaneous Closure of Patent Foramen Ovale With the GORE® Septal Occluder
    Knerr, Meike
    Bertog, Stefan
    Vaskelyte, Laura
    Hofmann, Ilona
    Sievert, Horst
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (07) : 1144 - 1151
  • [27] Comparison of atrial septal defect and patent foramen ovale in cryptogenic strokes
    Delabays, Constant
    Correia, Pamela
    Eeckhout, Eric
    Delabays, Alain
    Michel, Patrik
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2024, 33 (06)
  • [28] Relationship between patent foramen ovale anatomical features and residual shunt after patent foramen ovale closure
    Rie Nakayama
    Yoichi Takaya
    Teiji Akagi
    Rika Takemoto
    Madoka Haruna
    Mitsutaka Nakashima
    Takashi Miki
    Koji Nakagawa
    Norihisa Toh
    Kazufumi Nakamura
    Cardiovascular Intervention and Therapeutics, 2024, 39 : 200 - 206
  • [29] Patent Foramen Ovale Closure With the Gore Septal Occluder: Initial UK Experience
    Thomson, John D.
    Hildick-Smith, David
    Clift, Paul
    Morgan, Gareth
    Daniels, Matthew
    Henderson, Robert
    Spence, Mark S.
    Mahadevan, Vaikom S.
    Crossland, David
    Ormerod, Oliver
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (03) : 467 - 473
  • [30] Percutaneous Closure of Patent Foramen Ovale and Secundum Atrial Septal Defects with the GORE® CARDIOFORM Septal Occluder: Incidence and Implications of Device Wire Frame Fracture
    Castaldi, Biagio
    Cabrelle, Giulio
    Padalino, Massimo
    Vida, Vladimiro
    Milanesi, Ornella
    Di Salvo, Giovanni
    CONGENITAL HEART DISEASE, 2020, 15 (05) : 347 - 360