Haemodynamic effects of patent foramen ovale and atrial septal defect closure: a comparison during percutaneous shunt closure

被引:4
|
作者
Luermans, Justin G. L. M. [1 ]
Bos, Willem J. W. [2 ]
Post, Martijn C. [1 ]
ten Berg, Jurrien M. [1 ]
Plokker, H. W. Thijs [1 ]
Suttorp, Maarten J. [1 ]
机构
[1] St Antonius Hosp, Dept Cardiol, NL-3435 CM Nieuwegein, Netherlands
[2] St Antonius Hosp, Dept Internal Med, NL-3435 CM Nieuwegein, Netherlands
关键词
atrial septal defect; Finometer; haemodynamics; patent foramen ovale; transcatheter closure; TRANSCATHETER CLOSURE; ARTERIAL-PRESSURE; FINGER; HUMANS; FLOW;
D O I
10.1111/j.1475-097X.2009.00905.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
P>Objectives: We investigated the haemodynamic effect of percutaneous closure of an intra-atrial shunt, using non-invasive finger pressure measurements. Background: Percutaneous closure of both patent foramen ovale (PFO) and atrial septal defect (ASD) is widely practised. Currently no data are available on short-term haemodynamic changes induced by closure. Methods: Twenty-five consecutive patients (mean age 49 +/- 17 years, 10 men) who underwent a percutaneous closure of a PFO (n = 15) or ASD (n = 10) were included in this study. During the procedure blood pressure and heart rate (HR) were monitored continuously with a Finometer (R). Changes in systolic, mean, and diastolic pressure, stroke volume (SV), cardiac output (CO) and total peripheral resistance (TPR) were computed from the pressure registrations using Modelflow (R) methodology. Results: Baseline characteristics were similar for the PFO and ASD patients. After PFO closure none of the haemodynamic parameters changed significantly. After ASD closure the systolic, mean, and diastolic pressures increased 7 center dot 1 +/- 5 center dot 4 (P = 0 center dot 003), 3 center dot 8 +/- 3 center dot 5 (P = 0 center dot 007) and 2 center dot 0 +/- 3 center dot 0 mmHg (P = ns) respectively. HR decreased 5 center dot 1 +/- 5 center dot 3 beats per minute (P = 0 center dot 01). SV, CO and TPR increased 8 center dot 5 +/- 6 center dot 4 ml (13 center dot 5%; P = 0 center dot 002), 0 center dot 21 +/- 0 center dot 45 l min-1 (5 center dot 6%; P = ns) and 0 center dot 02 +/- 0 center dot 14 dynes (4 center dot 1%; P = ns) respectively. The changes in SV differ between the PFO and ASD patients (P = 0 center dot 009). Conclusions: Using non-invasive finger pressure measurements, we found that SV, mean and systolic blood pressure increased immediately after percutaneous closure of an ASD in adults, whereas the percutaneous PFO closure had no effect on haemodynamic characteristics.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 50 条
  • [1] Electrocardiographic Changes and Arrhythmias Following Percutaneous Atrial Septal Defect and Patent Foramen Ovale Device Closure
    Johnson, Jonathan N.
    Marquardt, Michelle L.
    Ackerman, Michael J.
    Asirvatham, Samuel J.
    Reeder, Guy S.
    Cabalka, Allison K.
    Cetta, Frank
    Hagler, Donald J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (02) : 254 - 261
  • [2] Echocardiographic Assessment of Percutaneous Patent Foramen Ovale and Atrial Septal Defect Closure Complications
    Yared, Kibar
    Baggish, Aaron L.
    Solis, Jorge
    Durst, Ronen
    Passeri, Jonathan J.
    Palacios, Igor F.
    Picard, Michael H.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2009, 2 (02) : 141 - 149
  • [3] Device closure of residual shunt after percutaneous closure of patent foramen ovale
    Majunke, Nicolas
    Wallenborn, Julia
    Baranowski, Andreas
    Wunderlich, Nina
    Sievert, Horst
    EUROINTERVENTION, 2010, 5 (07) : 833 - 837
  • [4] Patent foramen ovale and ventricular septal defect closure
    Wahl, A.
    Meier, B.
    HEART, 2009, 95 (01) : 70 - 82
  • [5] Patent Foramen Ovale and Atrial Septal Defect
    Aoun, Joe
    Hatab, Taha
    Volpi, John
    Lin, Chun Huie
    CARDIOLOGY CLINICS, 2024, 42 (03) : 417 - 431
  • [6] Patent Foramen Ovale and Atrial Septal Defect
    Majunke, N.
    Erbs, S.
    AKTUELLE KARDIOLOGIE, 2015, 4 (01) : 37 - 41
  • [7] Effect of percutaneous atrial septal defect and patent foramen ovale device closure on degree of aortic regurgitation
    Loar, Robert W.
    Johnson, Jonathan N.
    Cabalka, Allison K.
    Cetta, Frank
    Hagler, Donald J.
    Eidem, Benjamin W.
    Taggart, Nathaniel W.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (07) : 1234 - 1237
  • [8] Patent foramen ovale and atrial septal defect
    Kheiwa, Ahmed
    Hari, Pawan
    Madabhushi, Pranav
    Varadarajan, Padmini
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2020, 37 (12): : 2172 - 2184
  • [9] Percutaneous closure of patent foramen ovale
    Bijl, JM
    Ruygrok, PN
    Hornung, TS
    Wilson, NJ
    West, T
    INTERNAL MEDICINE JOURNAL, 2005, 35 (12) : 706 - 710
  • [10] Modified Technique to Control the Eutachian Valve During Transcatheter Closure of Atrial Septal Defect/Patent Foramen Ovale
    El Shedoudy, Sahar
    Abo Elsoud, Fatma
    El Dokhlaha, Eman
    Rashed, Reem
    Abdelghani, Mohammad
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (0D)