A systematic study on the influence of relative abundance of isotopes of elements in the coating (A(c)) and in the substrate (A(s)) on both shape of time-resolved signals and depth resolution (Delta z) was performed for depth profile analysis of metal coatings on metal substrates by ultraviolet (266 nm) nanosecond laser ablation inductively coupled plasma quadrupole mass spectrometry. Five coated samples with coating thicknesses of the same order of magnitude (20-30 mu m) were tested: nickel coating on aluminium, chromium and copper, and steel coated with copper and zinc. A laser repetition rate of 1 Hz and a laser fluence of 21 J cm(-2) were used. Five different depth profile types were established, which showed a clear dependence on A(c)/A(s) ratio. In general, depth profiles obtained for ratios above 1-10 could not be used to determine Delta z. We found that Delta z increased non-linearly with A(c)/A(s) ratio. The best depth profile types, leading to highest depth resolution and reproducibility, were attained in all cases by using the isotopes with low/medium A(c) values and with the highest A(s) values. In these conditions, an improvement of up to 4 times in Delta z values was achieved. The average ablation rates were in the range from 0.55 mu m pulse(-1) for copper coating on steel to 0.83 mu m pulse(-1) for zinc coating on steel, and the Delta z values were between 2.74 mu m for nickel coating on chromium and 5.91 mu m for nickel coating on copper, with RSD values about 5-8%. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:301 / 308
页数:8
相关论文
共 30 条
[1]   Application of laser ablation inductively coupled plasma (dynamic reaction cell) mass spectrometry for depth profiling analysis of high-tech industrial materials [J].
Balcaen, LIL ;
Lenaerts, J ;
Moens, L ;
Vanhaecke, F .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (05) :417-423
[2]   Use of a novel array detector for the direct analysis of solid samples by laser ablation inductively coupled plasma sector-field mass spectrometry [J].
Barnes, JH ;
Schilling, GD ;
Hieftje, GM ;
Sperline, RP ;
Denton, MB ;
Barinaga, CJ ;
Koppenaal, DW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (06) :769-776
[3]   Overcoming pulse mixing and signal tailing in laser ablation inductively coupled plasma mass spectrometry depth profiling [J].
Bleiner, D ;
Belloni, F ;
Doria, D ;
Lorusso, A ;
Nassisi, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (12) :1337-1343
[4]   Spatially resolved quantitative profiling of compositionally graded perovskite layers using laser ablation-inductively coupled plasma mass spectrometry [J].
Bleiner, D ;
Lienemann, P ;
Ulrich, A ;
Vonmont, H ;
Wichser, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (09) :1146-1153
[5]   Experimental determination of laser induced breakdown thresholds of metals under nanosecond Q-switched laser operation [J].
Cabalin, LM ;
Laserna, JJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (05) :723-730
[6]  
Chichkov BN, 1996, APPL PHYS A-MATER, V63, P109, DOI 10.1007/BF01567637
[7]   Depth profile analysis of copper coating on steel using laser ablation inductively coupled plasma mass spectrometry [J].
Coedo, AG ;
Dorado, T ;
Padilla, I ;
Fariñas, JC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (07) :612-620
[8]   Capabilities of laser ablation-inductively coupled plasma mass spectrometry for (trace) element analysis of car paints for forensic purposes [J].
Deconinck, I ;
Latkoczy, C ;
Günther, D ;
Govaert, F ;
Vanhaecke, F .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (03) :279-287
[9]   Laser ablation inductively coupled plasma mass spectrometry: achievements, problems, prospects [J].
Durrant, SF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1385-1403
[10]   Direct analysis of solid samples by fs-LA-ICP-MS [J].
Fernandez, Beatriz ;
Claverie, Fanny ;
Pecheyran, Christophe ;
Donard, Olivier F. X. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (10) :951-966