Performance Analysis of Micro-vertical Axis Wind Turbine Integrated with Upstream Omnidirectional Wind Deflector

被引:2
作者
Bashir Ali Bashir, Mohamed [1 ]
Ali, Imran [2 ]
Hussain Rajpar, Altaf [1 ]
机构
[1] Jouf Univ, Dept Mech Engn, Coll Engn, Sakaka 42421, Saudi Arabia
[2] Univ Malaysia Sarawak, Elect & Elect Engn Dept, Fac Engn, Kota Samarahan 94300, Malaysia
关键词
Vertical axis wind turbine; Wind deflector; Flow augmentation; Power coefficient; Torque coefficient; EFFICIENCY IMPROVEMENT; OPTIMIZATION; DESIGN; BLADE; PLATE; SHAPE;
D O I
10.1007/s13369-022-06896-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
It is still a desire for more local, small-scale power production that can be used to power very specific pieces of equipment or buildings. Innovation in micro-generation technologies reflects to generate heat or electricity at a small scale for individual buildings (or groups of buildings). The micro-wind sector is still at an early stage of development, but there is evidence of a growing market for the development of micro-wind systems. The performance parameters of the proposed lantern-type five-bladed micro-vertical axis wind turbine have been optimized. A novel approach of omnidirectional wind deflector with an optimized angle of attack guided the upstream wind to strike on the forward blade and thereby increase the turning speed. Furthermore, an upstream deflector produces a shield for the returning blade and diminishes the adverse effect on returning blade associated with speed of the wind turbine. Different locations and orientations of the proposed wind deflector were considered experimentally in terms of the normal displacement from the swept area of the turbine and varying the angle of the attack of the deflector to optimize the performance parameters of the turbine. A significant improvement in rotor speed, torque coefficient, and power coefficient was observed at upstream deflector angle of attack (70 degrees-80 degrees) when the turbine is subjected to wind velocity varying from 3.2 to 7 m/s as reported in result and discussion section. The best performance of wind turbine was observed at deflector angle of 70 degrees at a distance of 5 cm from the tip of rotor blade.
引用
收藏
页码:16239 / 16249
页数:11
相关论文
共 43 条
[1]   Four Decades of Research Into the Augmentation Techniques of Savonius Wind Turbine Rotor [J].
Alom, Nur ;
Saha, Ujjwal K. .
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2018, 140 (05)
[2]   Urban energy generation: Influence of micro-wind turbine output on electricity consumption in buildings [J].
Bahaj, A. S. ;
Myers, L. ;
James, P. A. B. .
ENERGY AND BUILDINGS, 2007, 39 (02) :154-165
[3]   Principle Parameters and Environmental Impacts that Affect the Performance of Wind Turbine: An Overview [J].
Bashir, Mohamed Bashir Ali .
ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2022, 47 (07) :7891-7909
[4]  
Betz A., 1920, Zeitschrift fur das gesamte Turbinenwesen, V26, P307
[5]   Performative analysis of an eccentric solar-wind combined system for steady power yield [J].
Bhattacharjee, Subhadeep ;
Acharya, Shantanu .
ENERGY CONVERSION AND MANAGEMENT, 2016, 108 :219-232
[6]   Novel plant development of a parallel matrix system of Savonius wind rotors with wind deflector [J].
Chen, Chang-An ;
Huang, Tien-Yang ;
Chen, Chiun-Hsun .
JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2015, 7 (01)
[7]   Efficiency improvement of a vertical-axis wind turbine using a deflector optimized by Taguchi approach with modified additive method [J].
Chen, Wei-Hsin ;
Wang, Jhih-Syun ;
Chang, Min-Hsing ;
Mutuku, Justus Kavita ;
Hoang, Anh Tuan .
ENERGY CONVERSION AND MANAGEMENT, 2021, 245
[8]  
Chong C. H., 2021, IOP Conference Series: Materials Science and Engineering, V1101, DOI 10.1088/1757-899X/1101/1/012034
[9]  
Claessens M., 2006, THESIS
[10]  
Crichton D., 2009, Adapting Buildings and Cities for Climate Change, DOI [10.4324/9780080961279, DOI 10.4324/9780080961279]