A comprehensive parametric investigation of hemispherical cavities on thermal performance and flow-dynamics in the triangular-duct solar-assisted air-heater

被引:35
|
作者
Goel, Varun [1 ]
Kumar, Rajneesh [2 ]
Bhattacharyya, Suvanjan [3 ]
Tyagi, V. V. [4 ,5 ]
Abusorrah, Abdullah M. [5 ,6 ]
机构
[1] Natl Inst Technol Hamirpur, Dept Mech Engn, Hamirpur 177005, HP, India
[2] Chandigarh Engn Coll Landran, Mech Engn Dept, Landran 140307, Punjab, India
[3] Birla Inst Technol & Sci Pilani, Dept Mech Engn, Pilani Campus, Vidya Vihar 333031, Rajasthan, India
[4] Shri Mata Vaishno Devi Univ, Sch Energy Management, Katra 182320, J&K, India
[5] King Abdulaziz Univ, Ctr Res Excellence Renewable Energy & Power Syst, Jeddah 21589, Saudi Arabia
[6] King Abdulaziz Univ, Fac Engn, Dept Elect & Comp Engn, Jeddah 21589, Saudi Arabia
关键词
Solar thermal; Dimple cavity; Vortex shedding; Performance; DIMPLED SURFACE; AUGMENTATION; ENHANCEMENT;
D O I
10.1016/j.renene.2021.04.006
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The thermal energy available in the form of solar radiation is collected and converted into heat with the help of a solar air heater. The flow and thermal characteristics change significantly with the crosssectional shape of the flow passage. The effect of hemispherical dimple-cavities that were employed over the heat-collector plate has been analyzed based on the flow and heat characteristics of a triangular solar air heater. A comprehensive investigation of roughness and flow parameters is carried out experimentally, while the flow dynamics over the heat-collector plate are predicted using commercial software (ANSYS). The remarkable results are observed in terms of Nusselt number and friction factor with the use of dimples over the heat-collector plate in the solar air heater. The higher heat transfer is noticed at the training edge in comparison to the leading edge of the dimple. The best augmentation in Nusselt number obtained is of the order of 5.33 that is observed for transverse-pitch ratio, longitudinal-pitch ratio and relative dimple depth values of 11, 11 and 0.039 respectively, at Reynolds number value of 2160. A close fit curve was obtained between the values obtained from the developed correlation and experimental values with a maximum error of 6.61% and 7.03%, respectively. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:896 / 912
页数:17
相关论文
共 25 条
  • [11] Numerical investigation on comparative performance assessment of solar air heater with different artificial roughness elements in a triangular duct
    Shaik, Rafiuzzama
    Punna, Eshwaraiah
    Gugulothu, S. K.
    JOURNAL OF THERMAL ENGINEERING, 2025, 11 (01): : 49 - 61
  • [12] Thermal performance analysis of triangular solar air heater duct having broken V-shaped ribs
    Agrawal R.K.
    Prasad R.S.
    International Journal of Ambient Energy, 2024, 45 (01)
  • [13] Numerical investigation of heat transfer and friction factor in ribbed triangular duct solar air heater using Computational fluid dynamics (CFD)
    Rajneesh Kumar
    Varun Goel
    Anoop Kumar
    Sourabh Khurana
    Paramvir Singh
    Santosh B. Bopche
    Journal of Mechanical Science and Technology, 2018, 32 : 399 - 404
  • [14] Numerical investigation of heat transfer and friction factor in ribbed triangular duct solar air heater using Computational fluid dynamics (CFD)
    Kumar, Rajneesh
    Goel, Varun
    Kumar, Anoop
    Khurana, Sourabh
    Singh, Paramvir
    Bopche, Santosh B.
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (01) : 399 - 404
  • [15] Effect of Base Angle of an Isosceles Trapezoidal Solar Air Heater Duct on Flow and Thermal Characteristics-A Numerical Investigation
    Dara, Rambabu
    Muvvala, Pullarao
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2023, 145 (04):
  • [16] Experimental investigation of thermal performance of a double-flow solar air heater having aluminium cans
    Ozgen, Filiz
    Esen, Mehmet
    Esen, Hikmet
    RENEWABLE ENERGY, 2009, 34 (11) : 2391 - 2398
  • [17] Comprehensive performance investigation of a novel solar-assisted liquid air energy storage system with different operating modes in different seasons
    Ding, Xingqi
    Zhou, Yufei
    Duan, Liqiang
    Li, Da
    Zheng, Nan
    ENERGY, 2023, 284
  • [18] Performance improvement and development of correlation for friction factor and heat transfer using computational fluid dynamics for ribbed triangular duct solar air heater
    Kumar, Rajneesh
    Kumar, Anoop
    Goel, Varun
    RENEWABLE ENERGY, 2019, 131 : 788 - 799
  • [19] An Experimental and Computational Investigation on Fluid Flow and Thermal Performance of a Rhombus Passage Solar Air Heater of Various Configurations
    Dara, Rambabu
    Muvvala, Pullarao
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024, 49 (08) : 10839 - 10857
  • [20] Experimental investigation on the dynamic thermal performance of the parallel solar-assisted air-source heat pump latent heat thermal energy storage system
    Jin, Xin
    Zhang, Huihui
    Huang, Gongsheng
    Lai, Alvin CK.
    RENEWABLE ENERGY, 2021, 180 : 637 - 657