Effects of Suture and Tourniquet on Intraoperative Kinematics in Navigated Total Knee Arthroplasty

被引:11
作者
Tsubosaka, Masanori [1 ]
Ishida, Kazunari [2 ]
Sasaki, Hiroshi [2 ]
Shibanuma, Nao [2 ]
Kuroda, Ryosuke [1 ]
Matsumoto, Tomoyuki [1 ]
机构
[1] Kobe Univ, Dept Orthopaed Surg, Grad Sch Med, Kobe, Hyogo, Japan
[2] Kobe Kaisei Hosp, Dept Orthopaed Surg, Kobe, Hyogo, Japan
关键词
total knee arthroplasty; tourniquet; soft tissue closure; navigation; kinematics; POSTERIOR CRUCIATE LIGAMENT; OSTEOARTHRITIC KNEES; PATELLOFEMORAL JOINT; FLEXION; ROTATION; MOTION; SYSTEM; RANGE; WEAR; GAP;
D O I
10.1016/j.arth.2017.01.033
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: To investigate the effects of suture (soft tissue closure) and air tourniquet use on intraoperative kinematics in navigated total knee arthroplasty. Methods: The study included 20 patients with varus-type knee osteoarthritis who underwent primary posterior-stabilized total knee arthroplasty using computed tomography (CT)-based navigation. Intraoperative tibiofemoral kinematics from maximum extension to maximum flexion were measured using the computed tomography-based navigation. The measurements were performed 3 times as follows: measurement 1: before suture (tourniquet on), measurement 2: after suture (tourniquet on), and measurement 3: after tourniquet removal. Details of kinematics including knee joint gap, tibiofemoral rotational angles, and anteroposterior (AP) distance between the femur and tibia were compared among the 3 measurements and statistically evaluated. Results: On the medial side, there was no significant difference among the 3 measurements in the extension gap, but measurement 1 showed a significantly larger flexion gap compared with the other 2 measurements. On the lateral side, there was no significant difference between the extension and flexion gaps in all measurements. The anteroposterior distance in measurement 1 showed that the femur was positioned significantly more anterior to the tibia at 10 degrees and 20 degrees of flexion compared with the other 2 measurements after suture. There was no significant difference among the 3 measurements in the tibiofemoral rotation angles. Conclusion: These results found that the effect of suture and tourniquet was minimal, and that intraoperative kinematics can effectively evaluate postoperative passive kinematic conditions. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:1824 / 1828
页数:5
相关论文
共 50 条
  • [21] Clinical effects of applying a tourniquet in total knee arthroplasty on blood loss
    Zhang Fu-jiang
    Xiao Yu
    Liu Ya-bin
    Tian Xu
    Gao Zhi-guo
    CHINESE MEDICAL JOURNAL, 2010, 123 (21) : 3030 - 3033
  • [22] The tourniquet's effects on skeletal muscle during total knee arthroplasty
    Johnsen, Magnus
    Mousavizadeh, Rouhollah
    Scott, Alex
    Havik, Steinar
    Husby, Vigdis S.
    Winther, Siri B.
    Husby, Otto S.
    Lian, Oystein
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2024, 42 (09) : 1955 - 1963
  • [23] The effects of tourniquet use in total knee arthroplasty: a randomized, controlled trial
    Kai Wang
    Songjia Ni
    Zhichang Li
    Qunjie Zhong
    Rujun Li
    Hu Li
    Yan Ke
    Jianhao Lin
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 2849 - 2857
  • [24] The effects of a tourniquet used in total knee arthroplasty: a meta-analysis
    Zhang, Wei
    Li, Ning
    Chen, Sifeng
    Tan, Yang
    Al-Aidaros, Mohammed
    Chen, Liaobin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2014, 9 : 13
  • [25] The effects of a tourniquet used in total knee arthroplasty: a meta-analysis
    Wei Zhang
    Ning Li
    Sifeng Chen
    Yang Tan
    Mohammed Al-Aidaros
    Liaobin Chen
    Journal of Orthopaedic Surgery and Research, 9
  • [26] Intraoperative manipulation for flexion contracture during total knee arthroplasty
    Matsui, Yoshio
    Matsuura, Masanori
    Minoda, Yukihide
    Nakagawa, Sigeru
    Okajima, Yoshiaki
    Kobayashi, Akio
    Inori, Fumiaki
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (01)
  • [27] Different intraoperative kinematics with comparable clinical outcomes of ultracongruent and posterior stabilized mobile-bearing total knee arthroplasty
    Kim, Tae Woo
    Lee, Sang Min
    Seong, Sang Cheol
    Lee, Sahnghoon
    Jang, Jak
    Lee, Myung Chul
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (09) : 3036 - 3043
  • [28] Silicone ring tourniquet or pneumatic cuff tourniquet for total knee arthroplasty
    Jean-Yves Jenny
    David Bahlau
    Sandra Wisniewski
    International Orthopaedics, 2016, 40 : 1803 - 1806
  • [29] Effect of tourniquet use on total blood loss following total knee arthroplasty
    Alzahrani, Khalid H.
    Alqarni, Abdulhakeem S.
    Taybe, Mazen M.
    Elkhashab, Ahmed M.
    Aljurayyan, Abdulaziz N.
    JOURNAL OF MUSCULOSKELETAL SURGERY AND RESEARCH, 2022, 6 (01) : 50 - 56
  • [30] Silicone ring tourniquet or pneumatic cuff tourniquet for total knee arthroplasty
    Jenny, Jean-Yves
    Bahlau, David
    Wisniewski, Sandra
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (09) : 1803 - 1806