Influence of PCA Components on Glucose Prediction using Non-invasive Technique

被引:0
作者
Parab, J. S. [1 ]
Gad, R. S. [1 ]
Naik, G. M. [1 ]
机构
[1] Goa Univ, Dept Elect, Taleigao Plateau, India
来源
2016 INTERNATIONAL CONFERENCE ON ADVANCES IN ELECTRICAL, ELECTRONIC AND SYSTEMS ENGINEERING (ICAEES) | 2016年
关键词
Non Invasive; PLSR; PCA; Diabetes; Multivariate;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
A truly noninvasive blood glucose-sensing device could revolutionalize diabetes treatment and coupled with advances in microelectronics can improve compliance with recommended glucose levels and greatly influence the cost of diabetes monitoring. The paper describes a Multivariate PLSR system for blood glucose prediction by considering 5 major variants in human blood i.e Glucose, Alanine, Ascorbate, Lactate and Urea. The typical biological system that resembles human blood tissue consisting of five major constituents has been tested on the Partial Least Square Regression (PLSR) model reported by the authors elsewhere. Multivariate PLSR model is experimentally validated for 12 templates recorded using Schimatzu FTIR 8400S in the range 400cm(-1) to 5000 cm(-1). The model was validated using 2 approaches, namely, Root Mean Square Error (RMSE) and Clark Error Grid Analysis (CEGA) plot. The dependence of variate prediction on Principal Component Analysis(PCA) factors is also described and analyzed in detail.
引用
收藏
页码:473 / 476
页数:4
相关论文
共 16 条
[1]   Noninvasive glucose sensing [J].
Arnold, MA ;
Small, GW .
ANALYTICAL CHEMISTRY, 2005, 77 (17) :5429-5439
[2]   Simultaneous measurements of glucose, glutamine, ammonia, lactate, and glutamate in aqueous solutions by near-infrared spectroscopy [J].
Chung, H ;
Arnold, MA ;
Rhiel, M ;
Murhammer, DW .
APPLIED SPECTROSCOPY, 1996, 50 (02) :270-276
[3]  
COPE M, 1991, P SOC PHOTO-OPT INS, V1431, P251, DOI 10.1117/12.44196
[4]   NONINVASIVE OPTICAL POLARIMETRIC GLUCOSE SENSING USING A TRUE PHASE MEASUREMENT TECHNIQUE [J].
COTE, GL ;
FOX, MD ;
NORTHROP, RB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (07) :752-756
[5]  
Eastman Richard C, 2002, Pediatr Diabetes, V3, P127, DOI 10.1034/j.1399-5448.2002.30302.x
[6]   PARTIAL LEAST-SQUARES REGRESSION - A TUTORIAL [J].
GELADI, P ;
KOWALSKI, BR .
ANALYTICA CHIMICA ACTA, 1986, 185 :1-17
[7]   Constrained optimization of Drude's equations eliminates effects of confounding molecules for the polarimetric measurement of glucose [J].
Güçlü, B ;
Engbretson, GA ;
Bolanowski, SJ .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (05) :967-977
[8]  
Hamy F. M., 1995, PHYSIOL MEAS, V37, P1
[9]  
Heise HM., 2002, NEAR INFRARED SPECTR
[10]  
Khalil Omar S, 2004, Diabetes Technol Ther, V6, P660, DOI 10.1089/dia.2004.6.660