An audit on transfusion of blood products based on clinical judgment in patients undergoing cardiac surgery

被引:0
作者
Paarel, Joseph Punnoose [1 ]
Rao, Vinay [2 ]
Ganesh, Anand [1 ]
Nair, Sukesh [3 ]
Dharmalingam, Sathish Kumar [1 ]
Kurien, Ben Babu [1 ]
Sahajanandan, Raj [1 ]
机构
[1] Christian Med Coll & Hosp, Dept Anaesthesia, Vellore, Tamil Nadu, India
[2] Christian Med Coll & Hosp, Dept Cardiovasc & Thorac Surg, Vellore, Tamil Nadu, India
[3] Christian Med Coll & Hosp, Dept Clin Pathol, Vellore, Tamil Nadu, India
关键词
Blood product transfusion; cardiopulmonary bypass; coagulation; cryoprecipitate; fresh-frozen plasma; thromboelastography; MANAGEMENT; PLASMA;
D O I
10.4103/TheIAForum.TheIAForum_41_21
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Transfusion of blood and blood products is strongly associated with increased morbidity and mortality in cardiovascular surgery. This includes transfusion-related acute lung injury, transfusion-associated circulatory overload, renal injury, anaphylactic reactions to blood products, and sepsis. Transfusion of blood products based on the clinician's judgment often results in excessive transfusion. Research suggests that the use of point-of-care (POC) coagulation tests coupled to algorithm-based management decrease transfusion requirements in cardiac surgery.& nbsp;Objectives: To determine abnormal thromboelastograph (TEG) values among patients who received blood products based on clinical judgment and to determine if a POC coagulation test could have resulted in reduced transfusion rates in these patients.& nbsp;Methods: A total of 45 cardiac surgical patients who received blood products during a 3 months period were included in the audit. Coagulation profile and TEG were sent before transfusion for all patients. Data were entered using EPIDATA software. Descriptive analysis was used to define the data. The Fisher exact test was used to assess differences between groups for categorical variables.& nbsp;Results: The R time was abnormal in 4.4% of patients, the Alpha angle was abnormal in 51.1% of patients, maximum amplitude was abnormal in 2.2% of patients, and there was no evidence of fibrinolysis on TEG in these patients.& nbsp;Conclusion: Clinical judgment about the need for blood transfusion had poor correlation with dynamic tests of coagulation. A POC test-based algorithm would have avoided a significant amount of blood product transfusion both in terms of choice of therapy and the dose of component used.
引用
收藏
页码:62 / 67
页数:6
相关论文
共 13 条
[1]   Comparison of structured use of routine laboratory tests or near-patient assessment with clinical judgement in the management of bleeding after cardiac surgery [J].
Avidan, MS ;
Alcock, EL ;
Da Fonseca, J ;
Ponte, J ;
Desai, JB ;
Despotis, GJ ;
Hunt, BJ .
BRITISH JOURNAL OF ANAESTHESIA, 2004, 92 (02) :178-186
[2]   Point-of-Care Coagulation Testing in Cardiac Surgery [J].
Bolliger, Daniel ;
Tanaka, Kenichi A. .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2017, 43 (04) :386-396
[3]  
Despotis GJ, 1997, CLIN CHEM, V43, P1684
[4]   The Operating Surgeon Is an Independent Predictor of Chest Tube Drainage Following Cardiac Surgery [J].
Dixon, Barry ;
Reid, David ;
Collins, Marnie ;
Newcomb, Andrew E. ;
Rosalion, Alexander ;
Yap, Cheng-Hon ;
Santamaria, John D. ;
Campbell, Duncan J. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2014, 28 (02) :242-246
[5]  
Enriquez L J, 2009, Br J Anaesth, V103 Suppl 1, pi14, DOI 10.1093/bja/aep318
[6]  
FERRARIS VA, 1995, TEX HEART I J, V22, P216
[7]   2011 Update to The Society of Thoracic Surgeons and the Society of Cardiovascular Anesthesiologists Blood Conservation Clinical Practice Guidelines [J].
Ferraris, Victor A. ;
Brown, Jeremiah R. ;
Despotis, George J. ;
Hammon, John W. ;
Reece, T. Brett ;
Saha, Sibu P. ;
Song, Howard K. ;
Clough, Ellen R. ;
Shore-Lesserson, Linda J. ;
Goodnough, Lawrence T. ;
Mazer, C. David ;
Shander, Aryeh ;
Stafford-Smith, Mark ;
Waters, Jonathan ;
Baker, Robert A. ;
Dickinson, Timothy A. ;
FitzGerald, Daniel J. ;
Likosky, Donald S. ;
Shann, Kenneth G. .
ANNALS OF THORACIC SURGERY, 2011, 91 (03) :944-982
[8]   Clinical decision versus thromboelastometry based fresh frozen plasma transfusion in cardiac surgery [J].
Meesters, M. I. ;
Koning, N. J. ;
Romijn, J. W. A. ;
Loer, S. A. ;
Boer, C. .
BRITISH JOURNAL OF ANAESTHESIA, 2017, 118 (03) :458-459
[9]   Reoperation for Bleeding in Patients Undergoing Coronary Artery Bypass Surgery Incidence, Risk Factors, Time Trends, and Outcomes [J].
Mehta, Rajendra H. ;
Sheng, Shubin ;
O'Brien, Sean M. ;
Grover, Frederick L. ;
Gammie, James S. ;
Ferguson, T. Bruce ;
Peterson, Eric D. .
CIRCULATION-CARDIOVASCULAR QUALITY AND OUTCOMES, 2009, 2 (06) :583-590
[10]   2017 EACTS/EACTA Guidelines on patient blood management for adult cardiac surgery The Task Force on Patient Blood Management for Adult Cardiac Surgery of the European Association for Cardio-Thoracic Surgery (EACTS) and the European Association of Cardiothoracic Anaesthesiology (EACTA) [J].
Pagano, Domenico ;
Milojevic, Milan ;
Meesters, Michael I. ;
Benedetto, Umberto ;
Bolliger, Daniel ' ;
von Heymann, Christian ;
Jeppsson, Anders ;
Koster, Andreas ;
Osnabrugge, Ruben L. ;
Ranucci, Marco ;
Ravn, Hanne Berg ;
Vonk, Alexander B. A. ;
Wahba, Alexander ;
Boer, Christa .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (01) :79-111