Hemodynamics of venous cuff interposition in prosthetic arteriovenous fistulas for hemodialysis

被引:7
作者
Lemson, S
Tordoir, JHM
Ezzahiri, R
Leunissen, KML
Kitslaar, PJEHM
Hoeks, APG
机构
[1] Univ Hosp Maastricht, Dept Surg, NL-6202 AZ Maastricht, Netherlands
[2] Univ Hosp Maastricht, Dept Nephrol, NL-6202 AZ Maastricht, Netherlands
[3] Maastricht Univ, Dept Biophys, Maastricht, Netherlands
[4] Maastricht Univ, Cardiovasc Res Inst Maastricht, Maastricht, Netherlands
关键词
arteriovenous fistulas; hemodialysis; intimal hyperplasia; venous cuff; hemodynamics;
D O I
10.1159/000066960
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose:The durability of prosthetic arteriovenous fistulas (AVF) for hemodialysis is jeopardized by thrombotic occlusions due to intimal hyperplastic stenoses. In arterial reconstructive surgery, peripheral arterial bypasses with prosthetic material benefit from a venous cuff at the distal anastomosis. Therefore, a study was performed to assess the effect of a venous cuff at the venous anastomosis of PTFE graft AVFs in terms of stenosis development, hemodynamics and patency rates. Methods: A subset of 40 patients from a multicenter study were enrolled into the study, of which 20 patients were randomized for venous cuff interposition. Duplex measurements to detect stenoses and volume flows were performed at 6, 12, 26 and 52 weeks postoperatively. Relative distension (RD) and wall shear rate (WSR) were calculated by means of vessel wall Doppler tracking (VWDT). Results: The total number of stenoses was significantly less in the cuff group (21 vs. 33; p = 0.045). This feature was found at the site of the venous anastomosis (cuff 5; no cuff 12). Volume flow, graft and efferent vein diameters, RD and WSR in the graft and efferent vein were comparable for both groups. WSR in the venous anastomosis tended to be lower in the cuff group (768 vs. 1,448 s(-1), p = 0.068). Volume flows and WSR were significantly lower in failing grafts. Patency rates were similar in both groups (primary patency 13 vs. 29%; secondary patency 78 vs. 67%). Conclusions: A venous cuff at the venous anastomosis of PTFE graft AVFs results in less stenoses, but improved patency rates could not be demonstrated. Copyright (C) 2002 S. Karger AG, Basel.
引用
收藏
页码:557 / 562
页数:6
相关论文
共 38 条
[21]  
Sottiurai V S, 1988, Eur J Vasc Surg, V2, P245, DOI 10.1016/S0950-821X(88)80034-3
[22]  
SOTTIURAI VS, 1994, INT ANGIOL, V13, P96
[23]  
SOTTIURAI VS, 1990, INT ANGIOL, V9, P59
[24]   MODULATION OF ARTERIAL SMOOTH-MUSCLE CELL-GROWTH BY HEMODYNAMIC FORCES [J].
STERPETTI, AV ;
CUCINA, A ;
SANTORO, L ;
CARDILLO, B ;
CAVALLARO, A .
EUROPEAN JOURNAL OF VASCULAR SURGERY, 1992, 6 (01) :16-20
[25]  
STONEBRIDGE PA, 1995, BRIT J SURG, V82, P555
[26]   VEIN CUFF INTERPOSITION PREVENTS JUXTA-ANASTOMOTIC NEOINTIMAL HYPERPLASIA [J].
SUGGS, WD ;
HENRIQUES, HF ;
DEPALMA, RG .
ANNALS OF SURGERY, 1988, 207 (06) :717-723
[27]  
SUMPIO BE, 1988, ARCH SURG-CHICAGO, V123, P1233
[28]   MECHANICAL-STRESS STIMULATES AORTIC ENDOTHELIAL-CELLS TO PROLIFERATE [J].
SUMPIO, BE ;
BANES, AJ ;
LEVIN, LG ;
JOHNSON, G .
JOURNAL OF VASCULAR SURGERY, 1987, 6 (03) :252-256
[29]   INTIMAL FIBROMUSCULAR HYPERPLASIA AT THE VENOUS ANASTOMOSIS OF PTFE GRAFTS IN HEMODIALYSIS-PATIENTS - CLINICAL, IMMUNOCYTOCHEMICAL, LIGHT AND ELECTRON-MICROSCOPIC ASSESSMENT [J].
SWEDBERG, SH ;
BROWN, BG ;
SIGLEY, R ;
WIGHT, TN ;
GORDON, D ;
NICHOLLS, SC .
CIRCULATION, 1989, 80 (06) :1726-1736
[30]  
Tordoir J H, 1988, Eur J Vasc Surg, V2, P3, DOI 10.1016/S0950-821X(88)80099-9