Tyrosinase based biosensor for the electrochemical determination of sulfamethoxazole

被引:43
作者
del Torno-de Roman, Lorena [1 ]
Asuncion Alonso-Lomillo, M. [1 ]
Dominguez-Renedo, Olga [1 ]
Julia Arcos-Martinez, M. [1 ]
机构
[1] Univ Burgos, Dept Analyt Chem, Fac Sci, Pza Misael Banuelos S-N, Burgos 09001, Spain
关键词
Biosensor; Screen-printed carbon electrodes; Gold nanoparticles; Tyrosinase Sulfamethoxazole; SOLID-PHASE EXTRACTION; PULSE VOLTAMMETRIC DETERMINATION; PERFORMANCE LIQUID-CHROMATOGRAPHY; CAPILLARY-ZONE-ELECTROPHORESIS; DOPED DIAMOND ELECTRODE; POTENTIOMETRIC TRANSDUCTION; WATER SAMPLES; WASTE-WATER; SULFONAMIDE RESIDUES; CATALYTIC-OXIDATION;
D O I
10.1016/j.snb.2015.12.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A disposable amperometric biosensor has been developed for the determination of sulfamethoxazole (SMX). Tyrosinase (TYR) has been cross -linked to screen-printed carbon electrodes previously modified by gold nanoparticles. The oxidation current recorded at +500 mV vs Ag/AgCl SPE has been related to SMX concentration. The biosensor showed an acceptable inter and intra immobilization assay, with a RSD of 5.8% (n = 4) and 6.7% (n = 4), respectively, in the concentration range from 20 mu m to 0.2 mM. The capability of detection was 22.6 +/- 2.1 OA for a probability of false positive and negative of 0.05. Finally, the developed biosensors have been successfully applied to the determination of SMX in different water samples. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:48 / 53
页数:6
相关论文
共 61 条
[1]  
Alegret S., 2004, SENSORES ELECTROQUIM
[2]   New and low cost plastic membrane electrode with low detection limits for sulfadimethoxine determination in aquaculture waters [J].
Almeida, S. A. A. ;
Montenegro, M. C. B. S. M. ;
Sales, M. G. F. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 709 :39-45
[3]   Optimizing potentiometric ionophore and electrode design for environmental on-site control of antibiotic drugs: Application to sulfamethoxazole [J].
Almeida, S. A. A. ;
Truta, Liliana A. A. N. A. ;
Queiros, Raquel B. ;
Montenegro, M. C. B. S. M. ;
Cunha, Alexandre L. ;
Sales, M. G. F. .
BIOSENSORS & BIOELECTRONICS, 2012, 35 (01) :319-326
[4]   Sulphonamide-imprinted sol-gel materials as ionophores in potentiometric transduction [J].
Almeida, S. A. A. ;
Moreira, F. T. C. ;
Heitor, A. M. ;
Montenegro, M. C. B. S. M. ;
Aguilar, G. G. ;
Sales, M. G. F. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2011, 31 (08) :1784-1790
[5]   Novel LTCC-potentiometric microfluidic device for biparametric analysis of organic compounds carrying plastic antibodies as ionophores: Application to sulfamethoxazole and trimethoprim [J].
Almeida, S. A. A. ;
Arasa, E. ;
Puyol, M. ;
Martinez-Cisneros, C. S. ;
Alonso-Chamarro, J. ;
Montenegro, M. C. B. S. M. ;
Sales, M. G. F. .
BIOSENSORS & BIOELECTRONICS, 2011, 30 (01) :197-203
[6]   Sulfadiazine-selective determination in aquaculture environment: Selective potentiometric transduction by neutral or charged ionophores [J].
Almeida, S. A. A. ;
Heitor, A. M. ;
Montenegro, M. C. B. S. M. ;
Sales, M. G. F. .
TALANTA, 2011, 85 (03) :1508-1516
[7]  
Almeida S.A.A., 2011, INT J ENVIRON AN CH, V92, P479
[8]   Optimization of the experimental parameters in the determination of rifamycin SV by adsorptive stripping voltammetry [J].
Alonso, MA ;
Sanllorente, S ;
Sarabia, LA ;
Arcos, MJ .
ANALYTICA CHIMICA ACTA, 2000, 405 (1-2) :123-133
[9]  
Alonso-Lomillo MA, 2009, BIOTECH AGR IND MED, P1
[10]   CYP450 2B4 covalently attached to carbon and gold screen printed electrodes by diazonium salt and thiols monolayers [J].
Alonso-Lomillo, M. A. ;
Yardimci, C. ;
Dominguez-Renedo, O. ;
Arcos-Martinez, M. J. .
ANALYTICA CHIMICA ACTA, 2009, 633 (01) :51-56