Combination of flow injection with capillary electrophoresis - Part 7. Microchip capillary electrophoresis system with flow injection sample introduction and amperometric detection

被引:59
作者
Fu, CG [1 ]
Fang, ZL [1 ]
机构
[1] Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110006, Peoples R China
基金
中国国家自然科学基金;
关键词
flow injection; capillary electrophoresis; microchip; amperometric detection; sugars;
D O I
10.1016/S0003-2670(00)01057-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microchip-based capillary electrophoresis (CE) system with amperometric detection, combined with flow injection (FI) sample introduction, was constructed from components readily available in the analytical laboratory. An H-channel configuration was used with separation capillary positioned between two tubular side-arms, and a falling-drop interface connected to one side-arm was developed to achieve electrical isolation between the FI and CE systems. End-column amperometric detection was accomplished with separation voltage decoupled from the detection system, employing a microdisk working electrode positioned immediately outside the capillary outlet in the other side-arm, which functioned as a large-volume reservoir. Sample dispersion in the FI system and the FI-CE interface was minimized by intercalating the sample zone between two air segments. Performance of the FI-CE amperometric system was demonstrated by separation of sugars. Separation of sucrose and glucose was performed with a 5 cm, 25 mu m i.d. capillary with 1.7 kV separation voltage in about 60 s (40 mu m plate height for glucose), achieving a sampling frequency of over 65 h(-1). Responses for sucrose and glucose were linear in the range of 10-1000 mu M with sensitivities of 0.011 and 0.025 nA mu M-1. Detection limits (S/N = 3) were 2 mu M for sucrose and 1 mu M for glucose. Peak height precisions were 2.1 and 2.4% R.S.D. (n = 9) for sucrose and glucose, respectively. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:71 / 79
页数:9
相关论文
共 24 条
[1]   Combination of flow injection with capillary electrophoresis. Part 5. Automated preconcentration and determination of pseudoephedrine in human plasma [J].
Chen, HW ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 1999, 394 (01) :13-22
[2]   Sequential injection sample introduction microfluidic-chip based capillary electrophoresis system [J].
Fang, Q ;
Wang, FR ;
Wang, SL ;
Liu, SS ;
Xu, SK ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) :27-37
[3]   Combination of flow injection with capillary electrophoresis .1. The basic system [J].
Fang, ZL ;
Liu, ZS ;
Shen, Q .
ANALYTICA CHIMICA ACTA, 1997, 346 (02) :135-143
[4]  
FU CG, 1998, CHINESE J ANAL CHEM, V26, P1085
[5]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[6]  
Holland LA, 1998, ANAL COMMUN, V35, p1H
[7]   IMPROVED END-COLUMN CONDUCTIVITY DETECTOR FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1991, 63 (19) :2193-2196
[8]   FUSED QUARTZ SUBSTRATES FOR MICROCHIP ELECTROPHORESIS [J].
JACOBSON, SC ;
MOORE, AW ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2059-2063
[9]   Integrated microdevice for DNA restriction fragment analysis [J].
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1996, 68 (05) :720-723
[10]   On-line coupling of gas diffusion to capillary electrophoresis [J].
Kuban, P ;
Karlberg, B .
TALANTA, 1998, 45 (03) :477-484