Optimal roof structure with multilayer cooling function materials for building energy saving

被引:19
|
作者
Zhang, Yixue [1 ]
Huang, Jiangchang [1 ]
Fang, Xiaoming [1 ,2 ]
Ling, Ziye [1 ,2 ]
Zhang, Zhengguo [1 ,2 ]
机构
[1] South China Univ Technol, Key Lab Enhanced Heat Transfer & Energy Conservat, Minist Educ, Sch Chem & Chem Engn, Guangzhou 510640, Guangdong, Peoples R China
[2] South China Univ Technol, Guangdong Engn Technol Res Ctr Efficient Heat Sto, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
building energy conservation; building envelope; cool roof; cooling performance; latent thermal energy storage; THERMAL PERFORMANCE; PERLITE COMPOSITE; PCM; STORAGE; VENTILATION; INSULATION; REDUCTION; ENVELOPE; COMFORT;
D O I
10.1002/er.4969
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Both cool roof and phase change thermal storage are promising technologies in decreasing building energy consumption. Combining these two technologies is likely to further enhance the thermal comfort of the building as well as reduce air condition loads. In this paper, the cooling performance and energy-saving effects of four types of roof (normal roof, phase change material [PCM] roof, cool roof, and cool PCM roof [cool roof coupled with PCM]) were investigated under a simulated sunlight. Experimental results indicate that compared with normal roof, the other three roofs are able to narrow the indoor temperature fluctuation and decrease the heat flow entering into the room. Among them, cool PCM roof gave the best energy-saving effect that can lower the indoor temperature and heat entering into rooms by 6.6 degrees C and 52.9%, respectively. Besides, the PCM location, PCM thickness, and insulation thickness exerted great impacts on the cooling performance of the roof. Placing the PCM on the internal layer beneath the extruded polystyrene (XPS) insulation board can make the indoor temperature 1.2 degrees C lower than that on the middle layer. Although thicker PCM panels or insulation boards can provide a better thermal insulation, 5 mm in PCM thickness and 20 mm in insulation thickness are enough to guarantee the indoor temperature of cool PCM roof system at a comfortable range (22 degrees C-28 degrees C) for a whole day. These findings will give guidance in designing buildings with a light and compact roof structure to decrease energy consumption and improve comfort level.
引用
收藏
页码:1594 / 1606
页数:13
相关论文
共 50 条
  • [1] Effect of building roof insulation measures on indoor cooling and energy saving in rural areas in Chongqing
    Ran, Jiandong
    Tang, Mingfang
    Jiang, Lin
    Zheng, Xing
    INTERNATIONAL HIGH-PERFORMANCE BUILT ENVIRONMENT CONFERENCE - A SUSTAINABLE BUILT ENVIRONMENT CONFERENCE 2016 SERIES (SBE16), IHBE 2016, 2017, 180 : 669 - 675
  • [2] Discuss on building energy saving and energy saving materials
    Wang, Shijin
    RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 2736 - 2739
  • [3] ENERGY SAVING THROUGH INTERMITTENT EVAPORATIVE ROOF COOLING
    ALTURKI, AM
    ZAKI, GM
    ENERGY AND BUILDINGS, 1991, 17 (01) : 35 - 42
  • [4] The impact of roof systems on cooling and building energy efficiency
    Wang, Yihang
    Wang, Zhi-Hua
    Rahmatollahi, Negar
    Hou, Haoran
    APPLIED ENERGY, 2024, 376
  • [5] A Study on the Energy-Saving Reconstruction of the Roof of Existing Building
    Han, Rubing
    Xu, Zhimao
    Long, Enshen
    Wang, Yan
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT PROTECTION, PTS 1-3, 2013, 361-363 : 440 - +
  • [6] Roof-integrated radiative air-cooling system to achieve cooler attic for building energy saving
    Zhao, Dongliang
    Aili, Ablimit
    Yin, Xiaobo
    Tan, Gang
    Yang, Ronggui
    ENERGY AND BUILDINGS, 2019, 203
  • [7] Performance Evolution of Roof Insulation Materials and Optimization of Energy Saving
    Sun J.
    Wang Z.
    She A.
    Ding Y.
    Tan Y.
    Jianzhu Cailiao Xuebao/Journal of Building Materials, 2019, 22 (04): : 611 - 616and625
  • [8] Dynamic analysis of daylight metrics and energy saving for rooftop window integrated flat roof structure of building
    Sudan, Madhu
    Tiwari, G. N.
    Al-Helal, I. M.
    SOLAR ENERGY, 2015, 122 : 834 - 846
  • [9] Simulated study on the potential of building energy saving using the green roof
    Zhang, Linfang
    Jin, Ming
    Liu, Jiying
    Zhang, Linhua
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 1469 - 1476
  • [10] Energy saving analysis of a transparent radiative cooling film for buildings with roof glazing
    Yi, Zhitong
    lv, Yingyan
    Xu, Dikai
    Xu, Jingtao
    Qian, Hua
    Zhao, Dongliang
    Yang, Ronggui
    Energy and Built Environment, 2021, 2 (02): : 214 - 222