Correlation of retention parameters of pesticides in normal and RP systems and their utilization for the separation of a mixture of ten urea herbicides and fungicides by two-dimensional TLC on cyanopropyl-bonded polar stationary phase and two-adsorbent-layer multi-K plate

被引:23
作者
Tuzimski, T [1 ]
Bartosiewicz, A [1 ]
机构
[1] Med Univ, Dept Inorgan & Analyt Chem, PL-20081 Lublin, Poland
关键词
thin-layer chromatography; 2D-TLC; correlation of retention in normal and reversed phase systems; pesticides;
D O I
10.1365/s10337-003-0116-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ten urea herbicides and fungicides have been separated by use of two-dimensional thin-layer chromatography. The largest differences are obtained by combination of normal-phase (NP) system and reversed-phase (RP) system on cyanopropyl-bonded polar adsorbents and on two adsorbent layer containing a narrow zone of octadecyl silica and adjacent a wide zone of silica (or vice versa). The greatest spread of points was obtained for combination of nonaqueous NP phases with ethyl acetate on silica and RP phases comprising a polar solvent (methanol) in water on octadecyl silica adsorbent wettable with water (RP-18W). A good spread of points was also obtained for pairs of normal-phase systems with heptane-ethyl acetate mobile phases and reversed-phase systems with water-dioxane mobile phases, both on thin layers of cyanopropyl-bonded polar adsorbents. The correlations of R-F values in NP/RP systems were utilized in practical separation of a mixture of ten urea pesticides using 2D-TLC on these adsorbents. The plates were scanned and videoscanned showing the real pictures of TLC chromatograms.
引用
收藏
页码:781 / 788
页数:8
相关论文
共 47 条
[1]   ONLINE LOW-LEVEL SCREENING OF POLAR PESTICIDES IN DRINKING AND SURFACE WATERS BY LIQUID-CHROMATOGRAPHY THERMOSPRAY MASS-SPECTROMETRY [J].
BAGHERI, H ;
BROUWER, ER ;
GHIJSEN, RT ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1993, 647 (01) :121-129
[2]   Determination of phenylurea herbicides in water samples using on-line sorptive preconcentration and high-performance liquid chromatography with UV of electrospray mass spectrometric detection [J].
Baltussen, E ;
Snijders, H ;
Janssen, HG ;
Sandra, P ;
Cramers, CA .
JOURNAL OF CHROMATOGRAPHY A, 1998, 802 (02) :285-295
[3]   Influence of the solvent on the gas chromatographic behaviour of urea herbicides [J].
Berrada, H ;
Font, G ;
Moltó, JC .
CHROMATOGRAPHIA, 2001, 54 (3-4) :253-262
[4]   Determination of herbicides, including thermally labile phenylureas, by solid-phase microextraction and gas chromatography-mass spectrometry [J].
Carabias-Martínez, R ;
García-Hermida, C ;
Rodríguez-Gonzalo, E ;
Soriano-Bravo, FE ;
Hernández-Méndez, J .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1002 (1-2) :1-12
[5]   Solid-phase extraction and sample stacking-micellar electrokinetic capillary chromatography for the determination of multiresidues of herbicides and metabolites [J].
Carabias-Martínez, R ;
Rodríguez-Gonzalo, E ;
Revilla-Ruiz, P ;
Domínguez-Alvarez, J .
JOURNAL OF CHROMATOGRAPHY A, 2003, 990 (1-2) :291-302
[6]   Determination of herbicides and metabolites by solid-phase extraction and liquid chromatography -: Evaluation of pollution due to herbicides in surface and groundwaters [J].
Carabias-Martínez, R ;
Rodríguez-Gonzalo, E ;
Herrero-Hernández, E ;
Sánchez-San Román, FJ ;
Flores, MGP .
JOURNAL OF CHROMATOGRAPHY A, 2002, 950 (1-2) :157-166
[7]   Multiresidue herbicide analysis in soil: Subcritical water extraction with an on-line sorbent trap [J].
Crescenzi, C ;
D'Ascenzo, G ;
Di Corcia, A ;
Nazzari, M ;
Marchese, S ;
Samperi, R .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2157-2163
[8]   Hot phosphate-buffered water extraction coupled on line with liquid chromatography/mass spectrometry for analyzing contaminants in soil [J].
Crescenzi, C ;
Di Corcia, A ;
Nazzari, M ;
Samperi, R .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3050-3055
[9]   Solid-phase extraction followed by high-performance liquid chromatography-ionspray interface-mass spectrometry for monitoring of herbicides in environmental water [J].
Curini, R ;
Gentili, A ;
Marchese, S ;
Marino, A ;
Perret, D .
JOURNAL OF CHROMATOGRAPHY A, 2000, 874 (02) :187-198
[10]  
Dzido T. N., 2001, PLANAR CHROMATOGRAPH, P68