Exercise physiology in left ventricular assist device patients: insights from hemodynamic simulations

被引:4
|
作者
Fresiello, Libera [1 ,2 ]
Gross, Christoph [3 ]
Jacobs, Steven [1 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Sci, Cardiac Surg, Leuven, Belgium
[2] CNR, Inst Clin Physiol, Pisa, Italy
[3] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Vienna, Austria
关键词
Exercise capacity; ventricular assist device; cardiovascular model; MECHANICAL CIRCULATORY SUPPORT; INCREASING PUMP SPEED; HEART-FAILURE; PULMONARY-HYPERTENSION; PHYSICAL-ACTIVITY; FLOW; CAPACITY; IMPLANTATION; SOCIETY; IMPACT;
D O I
10.21037/acs-2020-cfmcs-23
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Left ventricular assist devices (LVADs) assure longer survival to patients, but exercise capacity is limited compared to normal values. Overall, LVAD patients show high wedge pressure and low cardiac output during maximal exercise, a phenomenon hinting at the need for increased LVAD support. Clinical studies investigating the hemodynamic benefits of an LVAD speed increase during exercise, ended in inhomogeneous and sometimes contradictory results. The native ventricle- LVAD interaction changes between rest and exercise, and this evolution is complex, multifactorial and patient-specific. The aim of this paper is to provide a comprehensive overview on the patient-LVAD interaction during exercise and to delineate possible therapeutic strategies for the future. A computational cardiorespiratory model was used to simulate the hemodynamics of peak bicycle exercise in LVAD patients. The simulator included the main cardiovascular and respiratory impairments commonly observed in LVAD patients, so as to represent an average hemodynamic response to exercise. In addition, other exercise responses were simulated, by tuning the chronotropic, inotropic and vascular functions, and implementing aortic regurgitation and stenosis in the simulator. These profiles were tested under different LVAD speeds and LVAD pressure-flow characteristics. Simulations output showed consistency with clinical data from the literature. The simulator allowed the working condition of the assisted ventricle at exercise to be investigated, clarifying the reasons behind the high wedge pressure and poor cardiac output observed in the clinics. Patients with poorer inotropic, chronotropic and vascular functions, are likely to benefit more from an LVAD speed increase during exercise. Similarly, for these patients, a flatter LVAD pressure-flow characteristic can assure better hemodynamic support under physical exertion. Overall, the study evidenced the need for a patient-specific approach on supporting exercise hemodynamics. In this frame, a complex simulator can constitute a valuable tool to define and test personalized speed control algorithms and strategies.
引用
收藏
页码:339 / 352
页数:14
相关论文
共 50 条
  • [1] Exercise physiology, testing, and training in patients supported by a left ventricular assist device
    Loyaga-Rendon, Renzo Y.
    Plaisance, Eric P.
    Arena, Ross
    Shah, Keyur
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (08): : 1005 - 1016
  • [2] Hemodynamic exercise responses with a continuous-flow left ventricular assist device: Comparison of patients' response and cardiorespiratory simulations
    Gross, Christoph
    Fresiello, Libera
    Schloeglhofer, Thomas
    Dimitrov, Kamen
    Marko, Christiane
    Maw, Martin
    Meyns, Bart
    Wiedemann, Dominik
    Zimpfer, Daniel
    Schima, Heinrich
    Moscato, Francesco
    PLOS ONE, 2020, 15 (03):
  • [3] Hemodynamic parameters at rest predicting exercise capacity in patients supported with left ventricular assist device
    Hirotoshi Kato
    Togo Iwahana
    Ryohei Ono
    Sho Okada
    Goro Matsumiya
    Yoshio Kobayashi
    Journal of Artificial Organs, 2024, 27 : 7 - 14
  • [4] Hemodynamic parameters at rest predicting exercise capacity in patients supported with left ventricular assist device
    Kato, Hirotoshi
    Iwahana, Togo
    Ono, Ryohei
    Okada, Sho
    Matsumiya, Goro
    Kobayashi, Yoshio
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (01) : 7 - 14
  • [5] Left ventricular assist device: Hemodynamic profile
    Skubas, NJ
    Hyder, M
    Pasque, M
    Ruocco, E
    Lappas, DG
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2000, 14 (06) : 751 - 752
  • [6] Is hemodynamic transesophageal echocardiography needed for patients with left ventricular assist device?
    Bahatyrevich, Nataliya
    Yang, Qiong
    Cavarocchi, Nicholas C.
    Hirose, Hitoshi
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (03): : 1071 - 1077
  • [7] Remote hemodynamic monitoring for ambulatory left ventricular assist device patients
    Lampert, Brent C.
    Emani, Sitaramesh
    JOURNAL OF THORACIC DISEASE, 2015, 7 (12) : 2165 - 2171
  • [8] Invasive Hemodynamic Testing in Ambulatory Left Ventricular Assist Device Patients
    Badoe, N.
    Abdullah, K.
    Phillips, S.
    Nabut, J.
    Rongione, A. J.
    Desai, S. S.
    Shah, P.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S390 - S390
  • [9] Left Ventricular Assist Device Exercise Recommendations
    Sorace, Paul
    LaFontaine, Tom
    Batrakoulis, Alexios
    ACSMS HEALTH & FITNESS JOURNAL, 2023, 27 (02) : 59 - 62
  • [10] Clinical findings associated with incomplete hemodynamic left ventricular unloading in patients with a left ventricular assist device
    Ruiz-Cano, Maria J.
    Schramm, Rene
    Paluszkiewicz, Lech
    Ramazyan, Lilit
    Rojas, Sebastian V.
    Lauenroth, Volker
    Krenz, Adriana
    Gummert, Jan
    Morshuis, Michiel
    REVISTA ESPANOLA DE CARDIOLOGIA, 2022, 75 (08): : 626 - 635