Reliability of patient specific instrumentation in total knee arthroplasty

被引:0
作者
Jennart, Harold [1 ]
Yamben, Marie-Ange Ngo [1 ]
Kyriakidis, Theofylaktos [1 ]
Zorman, David [1 ]
机构
[1] CHU Tivoli, Dept Orthopaed & Traumatol, Tivoli, Belgium
来源
ACTA ORTHOPAEDICA BELGICA | 2015年 / 81卷 / 04期
关键词
PSI; TKA; navigation; HKA; CORONAL ALIGNMENT; ACCURACY;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of this study was to compare the precision between Patient Specific Instrumentation (PSI) and Conventional Instrumentation (CI) as determined intra-operatively by a pinless navigation system. Eighty patients were included in this prospective comparative study and they were divided into two homogeneous groups. We defined an original score from 6 to 30 points to evaluate the accuracy of the position of the cutting guides. This score is based on 6 objective criteria. The analysis indicated that PSI was not superior to conventional instrumentation in the overall score (p = 0.949). Moreover, no statistically significant difference was observed for any individual criteria of our score.
引用
收藏
页码:668 / 672
页数:5
相关论文
共 25 条
[1]   Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[2]   Preliminary experience with the patient-specific templating total knee arthroplasty 40 cases compared with a matched control group [J].
Boonen, Bert ;
Schotanus, Martijn G. M. ;
Kort, Nanne P. .
ACTA ORTHOPAEDICA, 2012, 83 (04) :387-393
[3]   Evaluation of the accuracy of patient-specific cutting blocks for total knee arthroplasty: a meta-analysis [J].
Cavaignac, Etienne ;
Pailhe, Regis ;
Laumond, Gregoire ;
Murgier, Jerome ;
Reina, Nicolas ;
Laffosse, Jean Michel ;
Berard, Emilie ;
Chiron, Philippe .
INTERNATIONAL ORTHOPAEDICS, 2015, 39 (08) :1541-1552
[4]   A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement [J].
Chareancholvanich, K. ;
Narkbunnam, R. ;
Pornrattanamaneewong, C. .
BONE & JOINT JOURNAL, 2013, 95B (03) :354-359
[5]   Less outliers in pinless navigation compared with conventional surgery in total knee arthroplasty [J].
Chen, Jerry Yongqiang ;
Chin, Pak Lin ;
Tay, Darren Keng Jin ;
Chia, Shi-Lu ;
Lo, Ngai Nung ;
Yeo, Seng Jin .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (08) :1827-1832
[6]  
Chen JY, 2014, KNEE SURG SPORTS TRA
[7]  
Chouteau J, 2011, REV CHIRURG ORTHOPED, V97, P3
[8]   A comparison of conventional and patient-specific instruments in total knee arthroplasty [J].
Daniilidis, Kiriakos ;
Tibesku, Carsten O. .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (03) :503-508
[9]   Coronal Alignment Correlates With Outcome After Total Knee Arthroplasty Five-Year Follow-Up of a Randomized Controlled Trial [J].
Huang, Nathaniel F. R. ;
Dowsey, Michelle M. ;
Ee, Eric ;
Stoney, James D. ;
Babazadeh, Sina ;
Choong, Peter F. .
JOURNAL OF ARTHROPLASTY, 2012, 27 (09) :1737-1741
[10]   CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT [J].
JEFFERY, RS ;
MORRIS, RW ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :709-714