摘要
We have developed a single photon emission computed tomography (SPECT) technique for high resolution radiotracer imaging of mice where the object is rotated instead of the scintillation camera. The system uses a 21 cm focal length pinhole collimator with a 0.5 mm diameter aperture, resulting in magnification ranging from 7 to 10 and acquisition times from 60 to 90 minutes. This method employs a plastic mouse-holding tube designed to address specific problems associated with pinhole SPECT, including low count rates and correction for shift of the center of rotation. Images of a novel "mouse heart" phantom demonstrated good image quality, uniformity, and spatial resolution. A Tc-99m-sestamibi scan of a normal mouse, electrocardiogram-gated at over 400 beats per minute, allowed assessment of regional myocardial perfusion and evaluation of ventricular wall motion. An ungated perfusion scan produced images with millimeter spatial resolution and quality comparable to human images, allowing the visualization of the left and right ventricular myocardium.
引用
收藏
页码:1218 / 1221
页数:4
相关论文
共 23 条
[1]  
Anger H O., 1967, Instrumentation in Nuclear Medicine
[2]  
Chatziioannou AF, 1999, J NUCL MED, V40, P1164
[3]   MicroPET: A high resolution PET scanner for imaging small animals [J].
Cherry, SR ;
Shao, Y ;
Silverman, RW ;
Meadors, K ;
Siegel, S ;
Chatziioannou, A ;
Young, JW ;
Jones, WF ;
Moyers, JC ;
Newport, D ;
Boutefnouchet, A ;
Farquhar, TH ;
Andreaco, M ;
Paulus, MJ ;
Binkley, DM ;
Nutt, R ;
Phelps, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1161-1166
[4]   Genes and physiology: Molecular physiology in genetically engineered animals [J].
Chien, KR .
JOURNAL OF CLINICAL INVESTIGATION, 1996, 97 (04) :901-909
[5]   Physiological assessment of complex cardiac phenotypes in genetically engineered mice [J].
Christensen, G ;
Wang, YB ;
Chien, KR .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1997, 272 (06) :H2513-H2524
[6]   Cardiovascular phenotyping in mice [J].
Doevendans, PA ;
Daemen, MJ ;
de Muinck, ED ;
Smits, JF .
CARDIOVASCULAR RESEARCH, 1998, 39 (01) :34-49
[7]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[8]   Conceptual design of a high-sensitivity small animal PET camera with 4π coverage [J].
Huber, JS ;
Moses, WW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :498-502
[9]   Cardiac physiology in transgenic mice [J].
James, JF ;
Hewett, TE ;
Robbins, J .
CIRCULATION RESEARCH, 1998, 82 (04) :407-415
[10]   PINHOLE COLLIMATION FOR ULTRA-HIGH-RESOLUTION, SMALL-FIELD-OF-VIEW SPECT [J].
JASZCZAK, RJ ;
LI, JY ;
WANG, HL ;
ZALUTSKY, MR ;
COLEMAN, RE .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :425-437