Reducing the matrix effects in chemical analysis: fusion of isotope dilution and standard addition methods

被引:15
作者
Pagliano, Enea [1 ]
Meija, Juris [1 ]
机构
[1] Natl Res Council Canada, Measurement Sci & Stand, 1200 Montreal Rd, Ottawa, ON K1A 0R6, Canada
关键词
chemical metrology; isotope dilution; matrix effect;
D O I
10.1088/0026-1394/53/2/829
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The combination of isotope dilution and mass spectrometry has become an ubiquitous tool of chemical analysis. Often perceived as one of the most accurate methods of chemical analysis, it is not without shortcomings. Current isotope dilution equations are not capable of fully addressing one of the key problems encountered in chemical analysis: the possible effect of sample matrix on measured isotope ratios. The method of standard addition does compensate for the effect of sample matrix by making sure that all measured solutions have identical composition. While it is impossible to attain such condition in traditional isotope dilution, we present equations which allow for matrix-matching between all measured solutions by fusion of isotope dilution and standard addition methods.
引用
收藏
页码:829 / 834
页数:6
相关论文
共 11 条