Comparison of dose response functions for EBT3 model GafChromic™ film dosimetry system

被引:28
|
作者
Aldelaijan, Saad [1 ,2 ,3 ,4 ]
Devic, Slobodan [1 ,2 ,5 ]
机构
[1] Jewish Gen Hosp, Radiat Oncol Dept, Montreal, PQ H3T 1E2, Canada
[2] McGill Univ, Med Phys Unit, Montreal, PQ H4A 3J1, Canada
[3] Montreal Neurol Inst, Biol & Biomed Engn Dept, Montreal, PQ H3A 2B4, Canada
[4] King Faisal Specialist Hosp & Res Ctr, Biomed Phys Dept, Riyadh, Saudi Arabia
[5] McGill Univ, Jewish Gen Hosp, Segal Canc Ctr, Montreal, PQ, Canada
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2018年 / 49卷
基金
加拿大自然科学与工程研究理事会;
关键词
Radiochromic film dosimetry system; Response function; PROTOCOL;
D O I
10.1016/j.ejmp.2018.05.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Different dose response functions of EBT3 model GafChromic (TM) film dosimetry system have been compared in terms of sensitivity as well as uncertainty vs. error analysis. We also made an assessment of the necessity of scanning film pieces before and after irradiation. Methods: Pieces of EBT3 film model were irradiated to different dose values in Solid Water (SW) phantom. Based on images scanned in both reflection and transmission mode before and after irradiation, twelve different response functions were calculated. For every response function, a reference radiochromic film dosimetry system was established by generating calibration curve and by performing the error vs. uncertainty analysis. Results: Response functions using pixel values from the green channel demonstrated the highest sensitivity in both transmission and reflection mode. All functions were successfully fitted with rational functional form, and provided an overall one-sigma uncertainty of better than 2% for doses above 2 Gy. Use of pre-scanned images to calculate response functions resulted in negligible improvement in dose measurement accuracy. Conclusion: Although reflection scanning mode provides higher sensitivity and could lead to a more widespread use of radiochromic film dosimetry, it has fairly limited dose range and slightly increased uncertainty when compared to transmission scan based response functions. Double-scanning technique, either in transmission or reflection mode, shows negligible improvement in dose accuracy as well as a negligible increase in dose uncertainty. Normalized pixel value of the images scanned in transmission mode shows linear response in a dose range of up to 11 Gy.
引用
收藏
页码:112 / 118
页数:7
相关论文
共 16 条
  • [1] An adaptive method for recalibrating Gafchromic EBT3 film
    Chang, Liyun
    Yeh, Shyh-An
    Ho, Sheng-Yow
    Ding, Hueisch-Jy
    Chen, Pang-Yu
    Lee, Tsair-Fwu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1007
  • [2] Comparative analysis of dosimetric uncertainty using Gafchromic™ EBT4 and EBT3 films in radiochromic film dosimetry
    Akdeniz, Yucel
    RADIATION PHYSICS AND CHEMISTRY, 2024, 220
  • [3] Comprehensive evaluation and new recommendations in the use of Gafchromic EBT3 film
    Liu, Kevin
    Jorge, Patrik Goncalves
    Tailor, Ramesh
    Moeckli, Raphael
    Schuler, Emil
    MEDICAL PHYSICS, 2023, 50 (11) : 7252 - 7262
  • [4] A protocol for EBT3 radiochromic film dosimetry using reflection scanning
    Papaconstadopoulos, Pavlos
    Hegyi, Gyorgy
    Seuntjens, Jan
    Devic, Slobodan
    MEDICAL PHYSICS, 2014, 41 (12)
  • [5] Radiochromic film dosimetry: Considerations on precision and accuracy for EBT2 and EBT3 type films
    Dreindl, Ralf
    Georg, Dietmar
    Stock, Markus
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2014, 24 (02): : 153 - 163
  • [6] Quality Assurance of a 50-kV Radiotherapy Unit Using EBT3 GafChromic Film: A Feasibility Study
    Steenbeke, Femke
    Gevaert, Thierry
    Tournel, Koen
    Engels, Benedikt
    Verellen, Dirk
    Storme, Guy
    De Ridder, Mark
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (01) : 163 - 170
  • [7] Optical Response of Expired EBT3 Film for Absorbed Dose Measurement in X-ray and Electron Beam Range
    Musa, Maisarah
    Abu Mhanna, Hamad Yahia
    Omar, Ahmad Fairuz
    Radzi, Yasmin Md
    Akhdar, Hanan Fawaz
    Ishak, Nor Hafizah
    Al Ewaidat, Haytham
    APPLIED SCIENCES-BASEL, 2022, 12 (08):
  • [8] Clinical use of Gafchromic EBT4 film for in vivo dosimetry for total body irradiation
    Draeger, Emily
    Guan, Fada
    Lee, Min-Young
    Han, Dae Yup
    Donahue, William
    Chen, Zhe
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (03):
  • [9] Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams
    Brown, Thomas A. D.
    Hogstrom, Kenneth R.
    Alvarez, Diane
    Matthews, Kenneth L., II
    Ham, Kyungmin
    Dugas, Joseph P.
    MEDICAL PHYSICS, 2012, 39 (12) : 7412 - 7417
  • [10] Improving the energy response of external beam therapy (EBT) GafChromic™ dosimetry films at low energies (≤100 keV)
    Bekerat, H.
    Devic, S.
    DeBlois, F.
    Singh, K.
    Sarfehnia, A.
    Seuntjens, J.
    Shih, Shelley
    Yu, Xiang
    Lewis, D.
    MEDICAL PHYSICS, 2014, 41 (02)