Comparison of cardiac computed tomography angiography and transoesophagea echocardiography for device surveillance after left atrial appendage closure

被引:74
作者
Qamar, Sadia R. [1 ]
Jalal, Sabeena [1 ]
Nicolaou, Savvas [1 ]
Tsang, Michael [2 ]
Gilhofer, Thomas [2 ]
Saw, Jacqueline [2 ]
机构
[1] Univ British Columbia, Vancouver Gen Hosp, Dept Radiol, Vancouver, BC, Canada
[2] Univ British Columbia, Vancouver Gen Hosp, Dept Cardiol, Vancouver, BC, Canada
基金
加拿大健康研究院; 美国国家卫生研究院;
关键词
atrial fibrillation; LAA closure; MSCT; other imaging modalities; CLINICAL IMPACT; FIBRILLATION; OBLITERATION; STROKE; ANTICOAGULATION; WATCHMAN; CT;
D O I
10.4244/EIJ-D-18-01107
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Device surveillance after left atrial appendage (LAA) closure (LAAC) is important to assess device positioning, peri-device leak (PDL) and device-related thrombus (DRT). There are limited data on the role of cardiac CT angiography (CCTA) after LAAC. We therefore sought to compare CCTA to trans-oesophagealechocardiography (TEE) in patients who successfully underwent LAAC. Methods and results: We report our consecutive series of non-valvular atrial fibrillation patients who underwent LAAC and had CCTA and TEE post LAAC. Prospective cardiac-gated CCTA was performed with the Toshiba 320-detector or Siemens second-generation 128-slice dual-source scanner, and post-processingwas performed with IMPAX 3D reformats. Glomerular filtration rate <30 mL/min/1.73 m(2) was an exclusion for CCTA. Device positioning, PDL or fabric leak, ratio of left atrial (LA) to LAA linear attenuation coefficient, and DRT were analysed. One hundred and two patients underwent LAAC (79 WATCHMAN,17 Amulet, 6 ACP). Mean age was 76.4 +/- 7.5 years, CHADS2 score 3.0 +/- 1.3, and CHADS-VASc score 4.6 +/- 1.6. CCTA was performed at a mean of 105.2 +/- 54.8 days, and TEE at a mean of 124.9 +/- 100.3 days post LAAC. LAA patency was observed in 52/100 (52%), with 45 (86.5%) via PDL and seven (13.5%) through fabric leak. Linear attenuation coefficient <100 HU and LA:LAA ratio <0.25 were seen in occluded devices. PDL was only observed in 35/102 (34.3%) on TEE. Mean device compression was greater with sealed devices (11.3 +/- 4.3% versus 8.2 +/- 4.0%, p<0.001). There was only one DRT, which was observed on both TEE and CCTA. Conclusions: CCTA is a suitable alternative to TEE for device surveillance post LAAC. CCTA was more sensitive than TEE for assessing PDL and can delineate the cause of residual LAA contrast patency.
引用
收藏
页码:663 / +
页数:10
相关论文
共 19 条
  • [1] Appendage obliteration to reduce stroke in cardiac surgical patients with atrial fibrillation
    Blackshear, JL
    Odell, JA
    [J]. ANNALS OF THORACIC SURGERY, 1996, 61 (02) : 755 - 759
  • [2] Camm AJ, 2012, EUR HEART J, V33
  • [3] Contrast Material-induced Nephrotoxicity and Intravenous Low-Osmolality Iodinated Contrast Material: Risk Stratification by Using Estimated Glomerular Filtration Rate
    Davenport, Matthew S.
    Khalatbari, Shokoufeh
    Cohan, Richard H.
    Dillman, Jonathan R.
    Myles, James D.
    Ellis, James H.
    [J]. RADIOLOGY, 2013, 268 (03) : 719 - 728
  • [4] Role of left atrial appendage obliteration in stroke reduction in patients with mitral valve prosthesis -: A transesophageal echocardiographic study
    García-Fernández, MA
    Pérez-David, E
    Quiles, J
    Peralta, J
    García-Rojas, I
    Bermejo, J
    Moreno, M
    Silva, J
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (07) : 1253 - 1258
  • [5] Warfarin use among ambulatory patients with nonvalvular atrial fibrillation: The AnTicoagulation and Risk Factors in Atrial Fibrillation (ATRIA) study
    Go, AS
    Hylek, EM
    Borowsky, LH
    Phillips, KA
    Selby, JV
    Singer, DE
    [J]. ANNALS OF INTERNAL MEDICINE, 1999, 131 (12) : 927 - +
  • [6] Can Contrast-Enhanced Multi-Detector Computed Tomography Replace Transesophageal Echocardiography for the Detection of Thrombogenic Milieu and Thrombi in the Left Atrial Appendage: A Prospective Study with 124 Patients
    Homsi, R.
    Nath, B.
    Luetkens, J. A.
    Schwab, J. O.
    Schild, H. H.
    Naehle, C. P.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (01): : 45 - 52
  • [7] Cardiac CT and Echocardiographic Evaluation of Peri-Device Flow After Percutaneous Left Atrial Appendage Closure Using the AMPLATZER Cardiac Plug Device
    Jaguszewski, Milosz
    Manes, Costantina
    Puippe, Gilbert
    Salzberg, Sacha
    Mueller, Maja
    Falk, Volkmar
    Luescher, Thomas
    Luft, Andreas
    Alkadhi, Hatem
    Landmesser, Ulf
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (02) : 306 - 312
  • [8] Success of surgical left atrial appendage closure
    Kanderian, Anne S.
    Gillinov, A. Marc
    Pettersson, Gosta B.
    Blackstone, Eugene
    Klein, Allan L.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (11) : 924 - 929
  • [9] Impact of Watchman and Amplatzer Devices on Left Atrial Appendage Adjacent Structures and Healing Response in a Canine Model
    Kar, Saibal
    Hou, Dongming
    Jones, Russell
    Werner, Dennis
    Swanson, Lynne
    Tischler, Brian
    Stein, Kenneth
    Huibregtse, Barbara
    Ladich, Elena
    Kutys, Robert
    Virmani, Renu
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (07) : 801 - 809
  • [10] Secular trends in incidence of atrial fibrillation in Olmsted County, Minnesota, 1980 to 2000, and implications on the projections for future prevalence
    Miyasaka, Yoko
    Barnes, Marion E.
    Gersh, Bernard J.
    Cha, Stephen S.
    Bailey, Kent R.
    Abhayaratna, Walter P.
    Seward, James B.
    Tsang, Teresa S. M.
    [J]. CIRCULATION, 2006, 114 (02) : 119 - 125