Long-Term Clinical Outcomes and Survivorship of Press-Fit Condylar Sigma Fixed-Bearing and Mobile-Bearing Total Knee Prostheses in the Same Patients

被引:31
|
作者
Kim, Young-Hoo [1 ]
Park, Jang-Won [1 ]
Kim, Jun-Shik [1 ]
Kulkarni, Sourabh S. [1 ]
Kim, Yoon-Hong [1 ]
机构
[1] Ewha Womans Univ, Sch Med, Ctr Joint Replacement, Seoul 158710, South Korea
关键词
IN-VIVO KINEMATICS; ROTATING-PLATFORM; JOINT REPLACEMENT; OXFORD KNEE; VALGUS KNEE; FOLLOW-UP; ARTHROPLASTY; DISLOCATION; SYSTEM;
D O I
10.2106/JBJS.M.01130
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: We are aware of no study that has compared press-fit condylar Sigma fixed-bearing and mobile-bearing total knee prostheses in the same patients after more than ten years of follow-up. The purpose of the current study was to compare these two implants with respect to the functional and radiographic results, prevalence of osteolysis, and overall revision rates at a mean of 12.1 years of follow-up. Methods: The study consisted of a consecutive series of 444 patients (mean age [and standard deviation], 66.5 +/- 7.4 years) who underwent simultaneous bilateral total knee arthroplasty, with one side treated immediately after the other. All of the patients received a press-fit condylar Sigma mobile-bearing prosthesis on one side and a press-fit condylar Sigma fixed-bearing prosthesis on the contralateral side. The minimum duration of follow-up was ten years (mean, 12.1 years; range, ten to thirteen years). At the time of each follow-up visit, the patients were assessed clinically and radiographically. Results: Postoperative total knee scores (95 and 94 points), Western Ontario and McMaster Universities Osteoarthritis Index (19 and 18 points), University of California, Los Angeles activity score (both prostheses, 5 points), range of motion (129 degrees +/- 6.3 degrees and 127 degrees +/- 6.8 degrees), and radiographic findings did not differ significantly between the press-fit condylar Sigma mobile and fixed-bearing designs at the final follow-up. The prevalence of aseptic loosening (1.4% and 1.8%) did not differ significantly between the mobile and fixed-bearing implant designs. No knee in either group had osteolysis. The estimated survival rate with revision as the end point was 98.2% (95% confidence interval, 91% to 99%) and 97.5% (95% confidence interval, 91% to 99%) at 12.1 years for the mobile and fixed-bearing implant groups, respectively. Conclusions: The results of the present long-term clinical study suggest that excellent clinical and radiographic results were achieved with both the press-fit condylar Sigma mobile and fixed-bearing cruciate-retaining total knee designs. We found no significant clinical advantage for a mobile-bearing over a fixed-bearing total knee prosthesis.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Comparison of long-term clinical outcomes after bilateral mobile-bearing total knee arthroplasties using PCL-retaining and PCL-substituting implants in the same patients
    Ishii, Yoshinori
    Noguchi, Hideo
    Sato, Junko
    Sakurai, Tetsuya
    Toyabe, Shin-ichi
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (12) : 3711 - 3717
  • [42] Comparative gravimetric wear analysis in mobile versus fixed-bearing posterior stabilized total knee prostheses
    Delport, Hendrik P.
    Vander Sloten, Jos
    Bellemans, Johan
    ACTA ORTHOPAEDICA BELGICA, 2010, 76 (03): : 367 - 373
  • [43] Does mobile-bearing have better flexion and axial rotation than fixed-bearing in total knee arthroplasty? A randomised controlled study based on gait
    Zeng, Yi-Ming
    Yan, Meng-Ning
    Li, Hui-Wu
    Zhang, Jun
    Wang, You
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 20 : 86 - 93
  • [44] Will Mobile-Bearing Total Knee Arthroplasty Be Lost to History? A Comparative Study of Long-Term Follow-Up
    Kim, Sangrim
    Yang, Joseph
    Moon, Seokhwan
    Choi, Sungwook
    LIFE-BASEL, 2024, 14 (10):
  • [45] Higher Axial Tibiofemoral Rotation and Functional Outcomes with Mobile-Bearing Compared with Fixed-Bearing Total Knee Arthroplasty at 1-but Not at 2-Year Follow-Up-A Randomized Clinical Trial
    Amaro, Joicemar Tarouco
    Novaretti, Joao Victor
    Astur, Diego Costa
    Batista Cavalcante, Elton Luiz
    Rodrigues Junior, Adilson Goes
    Debieux, Pedro
    Kaleka, Camila Cohen
    Cohen, Moises
    JOURNAL OF KNEE SURGERY, 2020, 33 (05) : 474 - 480
  • [46] Coronal Alignment of Fixed-Bearing Unicompartmental Knee Arthroplasty Femoral Component May Affect Long-Term Clinical Outcomes
    Khow, Yong Zhi
    Liow, Ming Han Lincoln
    Lee, Merrill
    Chen, Jerry Yongqiang
    Lo, Ngai Nung
    Yeo, Seng Jin
    JOURNAL OF ARTHROPLASTY, 2021, 36 (02) : 478 - 487
  • [47] Mobile-bearing versus fixed-bearing total knee implants. Results of a series of 100 randomised cases after 9 years follow-up
    Poirier, N.
    Graf, P.
    Dubrana, F.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (04) : S187 - S192
  • [48] Comparison of the PFC sigma fixed-bearing and rotating-platform total knee arthroplasty in the same patient - Short-term results
    Ranawat, AS
    Rossi, R
    Loreti, I
    Rasquinha, VJ
    Rodriguez, JA
    Ranawat, CS
    JOURNAL OF ARTHROPLASTY, 2004, 19 (01) : 35 - 39
  • [49] The effect of BMI on the mid-term clinical outcomes of mobile-bearing unicompartmental knee arthroplasty
    Liu, Yikai
    Gao, Huanshen
    Li, Tao
    Zhang, Zian
    Zhang, Haining
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [50] Improved Early Clinical Outcomes of RP/PS Mobile-Bearing Total Knee Arthroplasties
    Kim, Tae Kyun
    Cho, Hyung Joon
    Kang, Yeon Gwi
    Kim, Sung Ju
    Chang, Chong Bum
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (11) : 2901 - 2910