Measurement of platelet aggregation in ovine blood using a new impedance aggregometer

被引:20
作者
Baumgarten, Andrea
Wilhelmi, Mathias [2 ]
Kalbantner, Kerstin
Ganter, Martin [3 ]
Mischke, Reinhard [1 ]
机构
[1] Tierarztliche Hsch Hannover, Klin Kleintiere, Hannover Sch Vet Med, D-30173 Hannover, Germany
[2] Hannover Med Sch, Clin Cardiac Thorac Transplant & Vasc Surg, D-3000 Hannover, Germany
[3] Hannover Sch Vet Med, Clin Small Ruminants, D-3000 Hannover, Germany
关键词
ADP; collagen; impedance aggregometry; platelet aggregation; sheep; WHOLE-BLOOD; SPECIES VARIABILITY; MODEL; SHEEP; DEVICE; SHOCK; CLOT;
D O I
10.1111/j.1939-165X.2009.00198.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Whole blood platelet aggregometry (impedance) is an important method to investigate platelet function disorders. Examination of hemostatic function in sheep is important with respect to their role as an animal model of human disease. Objective The aim of this study was to evaluate and optimize selected methodological aspects (anticoagulant, agonist concentration) of impedance aggregometry in ovine blood using the new Multiplate 5.0 analyzer. Methods Blood samples were collected in hirudin anticoagulant from 40 clinically healthy sheep. Samples from selected sheep were collected in citrate, with or without the addition of calcium chloride. The agonists adenosine diphosphate (ADP), collagen, ristocetin, arachidonic acid, and thrombin receptor-activating peptide (TRAP) were added in several concentrations to induce aggregation. Results Based on maximum aggregation values and internal precision, no significant difference was found between ADP concentrations of 3-10 mu mol/L and collagen concentrations of 3-5 mu g/mL (P >.05). The lowest interindividual variation of approximately 3-4-fold was seen with 4 and 5 mu mol/L ADP and 4 and 5 mu g/mL collagen. Ristocetin, arachidonic acid, and TRAP did not induce significant aggregation at any concentration. Aggregation results were significantly lower when measured in citrate- vs hirudin-anticoagulated blood, regardless of the presence of calcium chloride. Conclusions Our results indicate that the multiplate impedance aggregometer is suitable for the measurement of platelet aggregation in sheep using optimal agonist concentrations of 4-5 mu mol/L ADP and 4-5 mu g/mL collagen. Hirudin-anticoagulated blood is the preferred sample material.
引用
收藏
页码:149 / 156
页数:8
相关论文
共 50 条
  • [21] Effect of iron therapy on the whole blood platelet aggregation in infants with iron deficiency anemia
    Kürekçi, AE
    Atay, AA
    Sarící, SÜ
    Zeybek, C
    Köseoglu, V
    Özcan, O
    [J]. THROMBOSIS RESEARCH, 2000, 97 (05) : 281 - 285
  • [22] Whole blood platelet aggregation measurement by Multiplate™: potential diagnostic inaccuracy of correcting the results for the sample platelet count
    Scavone, Mariangela
    Podda, Gian Marco
    Tripodi, Armando
    Cattaneo, Marco
    [J]. PLATELETS, 2023, 34 (01)
  • [23] EFFECTS OF PROCESSING AND STORAGE ON THE MEASUREMENT OF NITROGENOUS COMPOUNDS IN OVINE BLOOD
    LABORDE, CJ
    CHAPA, AM
    BURLEIGH, DW
    SALGADO, DJ
    FERNANDEZ, JM
    [J]. SMALL RUMINANT RESEARCH, 1995, 17 (02) : 159 - 166
  • [24] Whole blood platelet aggregation in humans and animals: A comparative study
    Soloviev, MV
    Okazaki, Y
    Harasaki, H
    [J]. JOURNAL OF SURGICAL RESEARCH, 1999, 82 (02) : 180 - 187
  • [25] Multiple electrode aggregometry:: A new device to measure platelet aggregation in whole blood
    Toth, Orsolya
    Calatzis, Andreas
    Penz, Sandra
    Losonczy, Hajna
    Siess, Wolfgang
    [J]. THROMBOSIS AND HAEMOSTASIS, 2006, 96 (06) : 781 - 788
  • [26] Use of magnetoelastic sensors for quantifying platelet aggregation I: Whole blood and platelet rich plasma
    Roy, Somnath C.
    Werner, Jacob R.
    Kouzoudis, Dimitris
    Grimes, Craig A.
    [J]. SENSOR LETTERS, 2008, 6 (02) : 280 - 284
  • [27] Time dependent reduction in platelet aggregation using the multiplate analyser and hirudin blood due to platelet clumping
    Chapman, Kent
    Favaloro, Emmanuel J.
    [J]. PLATELETS, 2018, 29 (03) : 305 - 308
  • [28] Microfluidic system for simultaneous optical measurement of platelet aggregation at multiple shear rates in whole blood
    Li, Melissa
    Ku, David N.
    Forest, Craig R.
    [J]. LAB ON A CHIP, 2012, 12 (07) : 1355 - 1362
  • [29] Platelet dysfunction and other hemostatic disorders in women with menorrhagia: the utility of whole blood lumi-aggregometer
    O. Meltem Akay
    Fezan Mutlu
    Zafer Gulbas
    [J]. Internal and Emergency Medicine, 2008, 3 : 191 - 193
  • [30] Evaluation of the Newly Developed Adenosine Diphosphate-Induced Platelet Aggregation Level System in Aggregometer on Automated Coagulation Analyzer
    Sakayori, Tasuku
    Kitano, Keisuke
    Watanabe, Yuri
    Omori, Yukari
    Ishida, Hidekazu
    Arai, Nobuo
    Uematsu, Kodai
    Enomoto, Yukiko
    Komiyama, Yutaka
    [J]. CLINICAL LABORATORY, 2019, 65 (12) : 2253 - 2260