Evaluation of simplified programs using the MED-EL C40+cochlear implant

被引:3
作者
Boyd, Paul J. [1 ]
机构
[1] Univ Manchester, Sch Psychol Sci, Audiol & Deafness Grp, Manchester M13 9PL, Lancs, England
关键词
Cochlear implant; Speech processor fitting; Electrode balancing; FACIAL-NERVE STIMULATION; COCHLEAR-IMPLANT; ELECTRODE IMPEDANCE; USERS; CHILDREN; THRESHOLDS; PARAMETERS; SETTINGS;
D O I
10.3109/14992021003663103
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
The present study evaluated the benefit possible from a cochlear implant (CI) using a simplified map (with a set of default parameters), rather than the conventional approach of producing a 'customized map' from electrode-specific psychophysical measures. Young children are sometimes initially provided with such maps and the aim was to gain an insight into what level of benefit they might provide. Maps with upper stimulation levels set equally across the array (i.e. 'flat' maps) were compared with normal 'customized' maps in established adult users of the MED-EL C40+ device. Speech discrimination was significantly poorer for the flat maps overall (mean of 72.7% for customized map, and 60.5% for flat map) and loudness balance estimates showed a range of degrees of imbalance. These results suggest that flat maps may provide paediatric CI users with useful levels of performance when psychophysical or objective measures cannot be obtained. The poorer performance with the flat map suggests that customized maps should be fit as soon as possible to provide paediatric patients with the maximum benefit of the CI device.
引用
收藏
页码:527 / 534
页数:8
相关论文
共 28 条
[1]  
Bamford J., 1979, SPEECH HEARING TESTS, P147
[2]  
Bigelow DC, 1998, AM J OTOL, V19, P163
[3]   Effects of programming threshold and maplaw settings on acoustic thresholds and speech discrimination with the MED-EL COMBI 40+ cochlear implant [J].
Boyd, Paul J. .
EAR AND HEARING, 2006, 27 (06) :608-618
[4]   Measurement of comfort levels by means of electrical stapedial reflex in children [J].
Bresnihan, M ;
Norman, G ;
Scott, F ;
Viani, L .
ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2001, 127 (08) :963-966
[5]  
Brickley Graham, 2005, Cochlear Implants Int, V6, P31, DOI 10.1002/cii.18
[6]  
Brill SM, 1997, AM J OTOL, V18, pS104
[7]   INTRAOPERATIVE AND POSTOPERATIVE ELECTRICALLY-EVOKED AUDITORY BRAIN-STEM RESPONSES IN NUCLEUS COCHLEAR IMPLANT USERS - IMPLICATIONS FOR THE FITTING PROCESS [J].
BROWN, CJ ;
ABBAS, PJ ;
FRYAUFBERTSCHY, H ;
KELSAY, D ;
GANTZ, BJ .
EAR AND HEARING, 1994, 15 (02) :168-176
[8]   The effect of loudness imbalance between electrodes in cochlear implant users [J].
Dawson, PW ;
Skok, M ;
Clark, GM .
EAR AND HEARING, 1997, 18 (02) :156-165
[9]   Implications of deep electrode insertion on cochlear implant fitting [J].
Gani, Mathieu ;
Valentini, Gregory ;
Sigrist, Alain ;
Kos, Maria-Izabel ;
Boex, Colette .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2007, 8 (01) :69-83
[10]  
Garnham Carolyn, 2002, Ear and Hearing, V23, P540, DOI 10.1097/00003446-200212000-00005