Computational Investigation of the Effect of Wall Thickness on Rupture Risk in Abdominal Aortic Aneurysms

被引:7
作者
Salman, H. E. [1 ,2 ]
Yalcin, H. C. [1 ]
机构
[1] Qatar Univ, Biomed Res Ctr, POB 2713, Doha, Qatar
[2] TOBB Univ Econ & Technol, Dept Mech Engn, Ankara, Turkey
关键词
Abdominal aortic aneurysm; Rupture risk assessment; Computational fluid dynamics; Fluid-structure interaction; Finite element analysis; Wall stress; FLUID-STRUCTURE INTERACTION; FINITE-ELEMENT-ANALYSIS; INTRALUMINAL THROMBUS; STRESS; HEMODYNAMICS; FLOW; MODEL; IDENTIFICATION; BIOMECHANICS; PREDICTION;
D O I
10.47176/jafm.14.02.31727
中图分类号
O414.1 [热力学];
学科分类号
摘要
Cardiovascular disorders are among the most important causes of sudden death and adult disability worldwide. Abdominal aortic aneurysm (AAA) is a critical clinical condition where the aorta dilates beyond 50% of its normal diameter and leads to a risk of rupture. In this study, we performed fluid-structure interaction (FSI) analysis on an eccentric computational AAA model in order to investigate the effects of wall thickness on AAA wall stresses, which are critically important to estimate the rupture risk. For this purpose, we modeled the problem domain using finite element analysis, and coupled the solutions of fluid and structure domains for improving the accuracy of results. ANSYS commercial finite element analysis software was used for modeling, solving, and post-processing the results. Expanded diameter in AAA sac resulted in altered hemodynamics. Wall shear stresses (WSS) caused by the flow are quite low on the AAA sac, which may deteriorate the endothelial cell regeneration and vascular remodeling in the long term. It is concluded that the most critical region for the rupture risk is the posterior distal end of AAA sac due to being exposed to peak mechanical stresses during the cardiac cycle. Obtained results shed light in understanding the rupture risk assessment of AAA.
引用
收藏
页码:499 / 513
页数:15
相关论文
共 58 条
[1]  
Amindari Armin, 2017, Informatics in Medicine Unlocked, V9, P191, DOI 10.1016/j.imu.2017.09.001
[2]  
Arzani A, 2015, J BIOMECH ENG-T ASME, V138
[3]   A longitudinal comparison of hemodynamics and intraluminal thrombus deposition in abdominal aortic aneurysms [J].
Arzani, Amirhossein ;
Suh, Ga-Young ;
Dalman, Ronald L. ;
Shadden, Shawn C. .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2014, 307 (12) :H1786-H1795
[4]   RUPTURED ABDOMINAL AORTIC-ANEURYSM - A POPULATION-BASED STUDY [J].
BENGTSSON, H ;
BERGQVIST, D .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (01) :74-80
[5]   Computational Fluid Dynamics of Developing Avian Outflow Tract Heart Valves [J].
Bharadwaj, Koonal N. ;
Spitz, Cassie ;
Shekhar, Akshay ;
Yalcin, Huseyin C. ;
Butcher, Jonathan T. .
ANNALS OF BIOMEDICAL ENGINEERING, 2012, 40 (10) :2212-2227
[6]   A FSI computational framework for vascular physiopathology: A novel. flow-tissue multiscale strategy [J].
Bianchi, Daniele ;
Monaldo, Elisabetta ;
Gizzi, Alessio ;
Marino, Michele ;
Filippi, Simonetta ;
Vairo, Giuseppe .
MEDICAL ENGINEERING & PHYSICS, 2017, 47 :25-37
[7]   Application of Fluid–Structure Interaction Methods to Estimate the Mechanics of Rupture in Asian Abdominal Aortic Aneurysms [J].
Canchi T. ;
Saxena A. ;
Ng E. ;
Pwee E.C. ;
Narayanan S. .
BioNanoScience, 2018, 8 (04) :1035-1044
[8]   Fluid-Structure Interaction Modeling of Abdominal Aortic Aneurysms: The Impact of Patient-Specific Inflow Conditions and Fluid/Solid Coupling [J].
Chandra, Santanu ;
Raut, Samarth S. ;
Jana, Anirban ;
Biederman, Robert W. ;
Doyle, Mark ;
Muluk, Satish C. ;
Finol, Ender A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (08)
[9]   Hemodynamics-driven deposition of intraluminal thrombus in abdominal aortic aneurysms [J].
Di Achille, P. ;
Tellides, G. ;
Humphrey, J. D. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2017, 33 (05)
[10]   Fluid-structure interaction within realistic three-dimensional models of the aneurysmatic aorta as a guidance to assess the risk of rupture of the aneurysm [J].
Di Martino, ES ;
Guadagni, G ;
Fumero, A ;
Ballerini, G ;
Spirito, R ;
Biglioli, P ;
Redaelli, A .
MEDICAL ENGINEERING & PHYSICS, 2001, 23 (09) :647-655