Photovoltaic thermal solar air heater under external recycle: A performance study

被引:9
作者
Kumar, Ajay [1 ]
Silswal, Shubham [1 ]
Dhiman, Prashant [1 ]
机构
[1] Natl Inst Technol Hamirpur, Dept Mech Engn, Hamirpur 177005, Himachal Prades, India
关键词
Photovoltaic thermal system; combined efficiency; recycle ratio; packing factor; double-pass solar collectors; EXPERIMENTAL VALIDATION; COLLECTOR; SYSTEMS; WATER;
D O I
10.1080/15567036.2021.1919793
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The photovoltaic thermal (PV/T) systems are promising techniques for cooling photovoltaic modules and performance improvement. The heat-exchanging fluid removes the heat from the PV module, which can be utilized in the low-temperature application, including space heating. In the present study, a photovoltaic thermal system based on a double pass air collector under recycling is theoretically investigated for its overall performance and analysis. An analytical model explaining the different temperatures and heat transfer characteristics of the proposed PV/T system is developed and employed to study the effects of different recycling ratios at varying mass flow rates, the area covered by the PV module (packing factor), solar irradiation, and varying duct depth on thermal, electrical, and combined efficiency. The analytical model utilizes an iterative solution to work out the governing energy balance equations describing the complex heat and mass exchanges. The results show that the new design collector encloses photovoltaic cells under recycling, reduces the PV surface temperature from 97 degrees C (without cooling) to 45 degrees C (with cooling) at 0.15 kg/sec mass flow rate of air and recycle ratio of 1.8 and, thereby improves the electrical efficiency from 12% to 16%, which is 13% more increment than a non-recycling case. The influences of the identified parameters, which may vary with the proposed design performance, are presented in detail.
引用
收藏
页数:17
相关论文
共 34 条
  • [1] Enviroeconomic analysis and energy matrices of glazed hybrid photovoltaic thermal module air collector
    Agrawal, Sanjay
    Tiwari, G. N.
    [J]. SOLAR ENERGY, 2013, 92 : 139 - 146
  • [2] Experimental validation of glazed hybrid micro-channel solar cell thermal tile
    Agrawal, Sanjay
    Tiwari, Arvind
    [J]. SOLAR ENERGY, 2011, 85 (11) : 3046 - 3056
  • [3] Alfegi M. Ebrahim Ali, 2008, American Journal of Applied Sciences, V5, P866, DOI 10.3844/ajassp.2008.866.871
  • [4] Ali Alfegi Ebrahim M., 2009, American Journal of Environmental Sciences, V5, P592, DOI 10.3844/ajessp.2009.592.598
  • [5] Maximising the energy output of a PVT air system
    Bambrook, S. M.
    Sproul, A. B.
    [J]. SOLAR ENERGY, 2012, 86 (06) : 1857 - 1871
  • [6] Recyclic double pass packed bed solar air heaters
    Dhiman, Prashant
    Singh, Satyender
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2015, 87 : 215 - 227
  • [7] Duffie JA, 2013, SOLAR ENGINEERING OF THERMAL PROCESSES, 4TH EDITION, P1, DOI 10.1002/9781118671603
  • [8] Optimisation of life cycle performance of a double-pass photovoltaic thermal-solar air heater with heat pipes
    Fan, Wenke
    Kokogiannakis, Georgios
    Ma, Zhenjun
    [J]. RENEWABLE ENERGY, 2019, 138 : 90 - 105
  • [9] SOME ASPECTS OF A PV/T COLLECTOR FORCED CIRCULATION FLAT-PLATE SOLAR WATER-HEATER WITH SOLAR-CELLS
    GARG, HP
    AGARWAL, RK
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1995, 36 (02) : 87 - 99
  • [10] Optimization of number of collectors for integrated PV/T hybrid active solar still
    Gaur, M. K.
    Tiwari, G. N.
    [J]. APPLIED ENERGY, 2010, 87 (05) : 1763 - 1772