Examination of musculoskeletal chest pain - An inter-observer reliability study

被引:9
|
作者
Brunse, Mads Hostrup [1 ,2 ]
Stochkendahl, Mette Jensen [1 ,2 ]
Vach, Werner [1 ,3 ]
Kongsted, Alice [1 ]
Poulsen, Erik [1 ,2 ]
Hartvigsen, Jan [1 ,2 ]
Christensen, Henrik Wulff [1 ,2 ]
机构
[1] Nord Inst Chiropract & Clin Biomech, Odense, Denmark
[2] Univ So Denmark, Inst Sports Sci & Clin Biomech, Odense, Denmark
[3] Univ So Denmark, Dept Stat, Odense, Denmark
关键词
Reliability; Palpation procedure; Physical examination; Chest pain; CLINICAL-PREDICTION RULE; LOW-BACK-PAIN; THORACIC SPINE; INTERRATER RELIABILITY; INTERVERTEBRAL MOTION; CLASSIFICATION-SYSTEM; LUMBAR SPINE; NECK PAIN; PALPATION; TESTS;
D O I
10.1016/j.math.2009.10.003
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Chest pain may be caused by joint and muscle dysfunction of the neck and thorax (termed musculoskeletal chest pain). The objectives of this study were (1) to determine inter-observer reliability of the diagnosis 'musculoskeletal chest pain' in patients with acute chest pain of non-cardiac origin using a standardized examination protocol, (2) to determine inter-observer reliability of single components of the protocol, and (3) to determine the effect of observer experience. Eighty patients were recruited from an emergency cardiology department. Patients were eligible if an obvious cardiac or non-cardiac diagnosis could not be established at the cardiology department. Four observers (two chiropractors and two chiropractic students) performed general health and manual examination of the spine and chest wall. Percentage agreement, Cohen's Kappa and ICC were calculated for observer pairs (chiropractors and students) and all. Musculoskeletal chest pain was diagnosed in 45 percent of patients. Inter-observer kappa values were substantial for the chiropractors and overall (0.73 and 0.62, respectively), and moderate for the students (0.47). For single items of the protocol, the overall kappa ranged from 0.01 to 0.59. Provided adequate training of observers, the examination protocol can be used in carefully selected patients in clinical settings and should be included in pre- and post-graduate clinical training. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:167 / 172
页数:6
相关论文
共 50 条
  • [41] Intra- and inter-observer reliability of Laredo classification system in Legg–Calvé–Perthes Disease
    Serkan Erkus
    Ali Turgut
    Onder Kalenderer
    Kivanc Yuksel
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 1043 - 1047
  • [42] Palpation for muscular tenderness in the anterior chest wall: An observer reliability study
    Christensen, HW
    Vach, W
    Manniche, C
    Haghfelt, T
    Hartvigsen, L
    Hoilund-Carlsen, PF
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2003, 26 (08) : 469 - 475
  • [43] The intra- and inter-observer reliability of interface pressure measurements of the Milwaukee brace in adolescents with hyperkyphosis
    Babaee, Taher
    Kamyab, Mojtaba
    Ahmadi, Amir
    Sanjari, Mohammad Ali
    Ganjavian, Mohammad Saleh
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2019, 32 (04) : 647 - 654
  • [44] The Effect of Clinical Knowledge and Surgical Experience on Treatment Choice in Legg-Calve-Perthes Disease: Intra-observer and Inter-observer Reliability Study
    Erkus, Serkan
    Kalenderer, Onder
    Turgut, Ali
    Bacaksiz, Tayfun
    Yuksel, Kivanc
    INDIAN JOURNAL OF ORTHOPAEDICS, 2020, 54 (04) : 477 - 485
  • [45] INTRA-OBSERVER AND DEVICE-DEPENDENT INTER-OBSERVER RELIABILITY OF CONTRAST-ENHANCED ULTRASOUND FOR MUSCLE PERFUSION QUANTIFICATION
    Kunz, Pierre
    Kiesl, Sophia
    Gro, Sascha
    Kauczor, Hans-Ulrich
    Schmidmaier, Gerhard
    Fischer, Christian
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (02) : 275 - 285
  • [46] Clinical screening tests for assessing movement control in non-specific low-back pain. A systematic review of intra- and inter-observer reliability studies
    Carlsson, Hannah
    Rasmussen-Barr, Eva
    MANUAL THERAPY, 2013, 18 (02) : 103 - 110
  • [47] Inter-rater reliability of select physical examination procedures in patients with neck pain
    Hanney, William J.
    George, Steven Z.
    Kolber, Morey J.
    Young, Ian
    Salamh, Paul A.
    Cleland, Joshua A.
    PHYSIOTHERAPY THEORY AND PRACTICE, 2014, 30 (05) : 345 - 352
  • [48] Measuring the intercondylar shelf angle using radiographs: Intra- and inter-observer error tests of reliability
    Berg, Gregory E.
    Ta'ala, Sabrina C.
    Kontanis, Elias J.
    Leney, Sardiaa S.
    JOURNAL OF FORENSIC SCIENCES, 2007, 52 (05) : 1020 - 1024
  • [49] Inter-observer agreement according to malaria parasite density
    Billo, Mounkaila Abdou
    Diakite, Mahamadou
    Dolo, Amagana
    Diallo, Mouctar
    Poudiougou, Belco
    Diawara, Sory Ibrahima
    Johnson, Eric S.
    Rice, Janet C.
    Krogstad, Donald J.
    Doumbo, Ogobara K.
    MALARIA JOURNAL, 2013, 12
  • [50] Intra- and inter-observer reliability of Laredo classification system in Legg-Calve-Perthes Disease
    Erkus, Serkan
    Turgut, Ali
    Kalenderer, Onder
    Yuksel, Kivanc
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (05) : 1043 - 1047