Silver ion-selective electrodes using π-coordinate calix[4]arene derivatives as soft neutral carriers

被引:110
作者
Kimura, K [1 ]
Yajima, S [1 ]
Tatsumi, K [1 ]
Yokoyama, M [1 ]
Oue, M [1 ]
机构
[1] Wakayama Univ, Fac Syst Engn, Dept Appl Chem, Wakayama 6408510, Japan
关键词
D O I
10.1021/ac000490d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Calix[4]arene derivatives incorporating pi -coordinate substituents such as allyl, benzyl, and propargyl groups were designed as soft neutral carriers for silver ion sensors. Most of all, tert-butylcalix[4]arene tetra(allyl ether) is an excellent neutral carrier for plasticized poly(vinyl chloride)membrane sih er ion-selective electrodes. The ion sensors showed high silver ion selectivity over alkali metal ions and also good selectivity against other soft metal ions such as lead and mercury(II) ions. The electrode potential response was as rapid as that for neutral-carrier-type alkali metal ion electrodes due to the soft interaction between pi -coordinate substituents and silver ion, which was elucidated by H-1 NMR spectroscopy.
引用
收藏
页码:5290 / 5294
页数:5
相关论文
共 23 条
  • [11] CALIXARENES-9 - CONFORMATIONAL ISOMERS OF THE ETHERS AND ESTERS OF CALIX[4]ARENES
    GUTSCHE, CD
    DHAWAN, B
    LEVINE, JA
    NO, KH
    BAUER, LJ
    [J]. TETRAHEDRON, 1983, 39 (03) : 409 - 426
  • [12] NMR SPECTROSCOPIC AND X-RAY CRYSTALLOGRAPHIC STUDIES OF CALIX[4]ARENE AG+ COMPLEXES - INFLUENCE OF BOUND AG+ ON C-2V-C-2V INTERCONVERSION IN CONE-CALIX[4]ARENES
    IKEDA, A
    TSUZUKI, H
    SHINKAI, S
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1994, (10): : 2073 - 2080
  • [13] SYNTHESES AND ION SELECTIVITY OF ALL CONFORMATIONAL ISOMERS OF TETRAKIS((ETHOXYCARBONYL)METHOXY)CALIX[4]ARENE
    IWAMOTO, K
    SHINKAI, S
    [J]. JOURNAL OF ORGANIC CHEMISTRY, 1992, 57 (26) : 7066 - 7073
  • [14] Calix[4]arene derivative bearing π-coordinate substituents as neutral carrier for silver ion sensors
    Kimura, K
    Tatsumi, K
    Yajima, S
    Miyake, S
    Sakamoto, H
    Yokoyama, M
    [J]. CHEMISTRY LETTERS, 1998, (08) : 833 - 834
  • [15] Remarkable thallium(I) selectivity for ion sensors based on π-coordination of calix[4]arene neutral carriers
    Kimura, K
    Tatsumi, K
    Yokoyama, M
    Ouchi, M
    Mocerino, M
    [J]. ANALYTICAL COMMUNICATIONS, 1999, 36 (06): : 229 - 230
  • [16] POLYMERIC MEMBRANE SODIUM-SELECTIVE ELECTRODES BASED ON LIPOPHILIC CALIX[4]ARENE DERIVATIVES
    KIMURA, K
    MIURA, T
    MATSUO, M
    SHONO, T
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (14) : 1510 - 1513
  • [17] MERCURY(II) AND SILVER(I) ION-SELECTIVE ELECTRODES BASED ON DITHIA CROWN ETHERS
    LAI, MT
    SHIH, JS
    [J]. ANALYST, 1986, 111 (08) : 891 - 895
  • [18] Synthesis and 1H NMR studies of vinyl-substituted calix[4]arene derivatives:: Enhanced cation-π interactions with extended calix[4]arene π-systems
    Lhotak, P
    Nakamura, R
    Shinkai, S
    [J]. SUPRAMOLECULAR CHEMISTRY, 1997, 8 (04) : 333 - 344
  • [19] LUTTERER T, 1997, ANGEW CHEM INT EDIT, V6, P611
  • [20] SILVER SELECTIVE ELECTRODES BASED ON THIOETHER FUNCTIONALIZED CALIX[4]ARENES AS IONOPHORES
    MALINOWSKA, E
    BRZOZKA, Z
    KASIURA, K
    EGBERINK, RJM
    REINHOUDT, DN
    [J]. ANALYTICA CHIMICA ACTA, 1994, 298 (02) : 245 - 251