Reliability of Allen's test in selection of patients for radial artery harvest

被引:114
作者
Jarvis, MA [1 ]
Jarvis, CL [1 ]
Jones, PRM [1 ]
Spyt, TJ [1 ]
机构
[1] Glenfield Hosp, Dept Cardiothorac Surg, Leicester, Leics, England
关键词
D O I
10.1016/S0003-4975(00)01551-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Alien's test is widely used to assess the ulnar collateral blood supply of the hand before radial artery harvest for coronary bypass surgery. This study was performed to determine the optimum cut-off point for a positive Alien's test and the clinical reliability of Alien's test in this role. Methods. Patients undergoing coronary artery bypass surgery were examined by independent observers using both Alien's test and a Doppler ultrasound test of the ulnar collateral circulation. Results. We examined 93 hands in 47 patients; mean age was 63.6 years. Receiver operating characteristic analysis found that at a conventional cut-off of 6 seconds on Alien's test had a sensitivity of 54.5%, specificity of 91.7%, and diagnostic accuracy of 78.5%. At a cut-off of 5 seconds diagnostic accuracy was maximal (79.6%), with sensitivity of 75.8% and specificity of 81.7%; 100% sensitivity occurred at a cut-off of 3 seconds, with specificity of 27% and diagnostic accuracy of 52%. Conclusions. At no cut-off point does Alien's test perform satisfactorily as a discriminatory test. It should be replaced by more objective tests, such as Doppler ultrasound. (C) 2000 by The Society of Thoracic Surgeons.
引用
收藏
页码:1362 / 1365
页数:4
相关论文
共 20 条
  • [11] KAMIENSKI RW, 1976, SURG GYNECOL OBSTET, V142, P861
  • [12] RADIAL AND ULNAR ARTERY DOMINANCE IN NORMAL DIGITS
    KLEINERT, JM
    FLEMING, SG
    ABEL, CS
    FIRRELL, J
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1989, 14A (03): : 504 - 508
  • [13] Marcillon M, 1982, Ann Fr Anesth Reanim, V1, P403, DOI 10.1016/S0750-7658(82)80021-X
  • [14] PRIMER ON CERTAIN ELEMENTS OF MEDICAL DECISION-MAKING
    MCNEIL, BJ
    KEELER, E
    ADELSTEIN, SJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1975, 293 (05) : 211 - 215
  • [15] EVALUATION OF RECEIVER OPERATING CHARACTERISTIC CURVE DATA IN TERMS OF INFORMATION-THEORY, WITH APPLICATIONS IN RADIOGRAPHY
    METZ, CE
    GOODENOUGH, DJ
    ROSSMANN, K
    [J]. RADIOLOGY, 1973, 109 (02) : 297 - 303
  • [16] Safe removal of the radial artery for myocardial revascularization: A Doppler study to prevent ischemic complications to the hand
    Pola, P
    Serricchio, M
    Flore, R
    Manasse, E
    Favuzzi, A
    Possati, GF
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (03) : 737 - 744
  • [17] RITCHIE AJ, SOC CARD SURG GREAT
  • [18] A QUANTITATIVE ALLENS TEST
    SCAVENIUS, M
    FAUNER, M
    WALTHERLARSEN, S
    BUCHWALD, C
    NIELSEN, SL
    [J]. HAND, 1981, 13 (03): : 318 - 320
  • [19] WHITNEY RJ, 1953, J PHYSIOL-LONDON, V121, P1
  • [20] RELATIONSHIP BETWEEN PULSE VOLUME AND BLOOD FLOW IN FINGER
    ZWEIFLER, AJ
    CUSHING, G
    CONWAY, J
    [J]. ANGIOLOGY, 1967, 18 (10) : 591 - &