A Mobile Monitoring System of Blood Pressure for Underserved in China by Information and Communication Technology Service

被引:10
作者
Jiang, Jiehui [1 ]
Yan, Zhuangzhi [2 ]
Shi, Jun [2 ]
Kandachar, Prabhu [1 ]
Freudenthal, Adinda [1 ]
机构
[1] Delft Univ Technol, Fac Ind Design Engn, Dept Design Engn, NL-2628 CE Delft, Netherlands
[2] Shanghai Univ, Inst Biomed Engn, Sch Commun & Informat Engn, Shanghai 200444, Peoples R China
来源
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE | 2010年 / 14卷 / 03期
关键词
Blood pressure (BP); community healthcare center (CHC); measurement; short messaging service (SMS); UPPER ARM; WRIST;
D O I
10.1109/TITB.2010.2043534
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
High blood pressure (BP, hypertension) is a leading chronic condition in China and has become the main risk factor for many high-risk diseases, such as heart attacks. However, the platform for chronic disease measurement and management is still lacking, especially for underserved Chinese. To achieve the early diagnosis of hypertension, one BP monitoring system has been designed. The proposed design consists of three main parts: user domain, server domain, and channel domain. All three units and their materialization, validation tests on reliability, and usability are described in this paper, and the conclusion is that the current design concept is feasible and the system can be developed toward sufficient reliability and affordability with further optimization. This idea might also be extended into one platform for other physiological signals, such as blood sugar and ECG.
引用
收藏
页码:748 / 757
页数:10
相关论文
共 24 条
  • [1] Axisa F, 2004, P ANN INT IEEE EMBS, V26, P2161
  • [2] Axosa F., 2003, P IEEE EMBC CANC MEX, P3744
  • [3] Bald M, 1996, Z KARDIOL, V85, P106
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] BRIEN E, 2003, J HYPERTENS, V21, P821
  • [6] BRIEN O, 2001, BMJ-BRIT MED J, V322, P531
  • [7] Eckert S, 1996, Z KARDIOL, V85, P109
  • [8] EVANS CE, 1989, J HYPERTENS, V7, P133
  • [9] DIRECT BLOOD-PRESSURE MEASUREMENT - DYNAMIC-RESPONSE REQUIREMENTS
    GARDNER, RM
    [J]. ANESTHESIOLOGY, 1981, 54 (03) : 227 - 236
  • [10] CHARACTERIZATION OF THE OSCILLOMETRIC METHOD FOR MEASURING INDIRECT BLOOD-PRESSURE
    GEDDES, LA
    VOELZ, M
    COMBS, C
    REINER, D
    BABBS, CF
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1982, 10 (06) : 271 - 280