Application of a CO2 dial system for infrared detection of forest fire and reduction of false alarm

被引:27
作者
Bellecci, C.
Francucci, M.
Gaudio, P.
Gelfusa, M.
Martellucci, S.
Richetta, M.
Lo Feudo, T.
机构
[1] Univ Roma Tor Vergata, Fac Engn, I-00133 Rome, Italy
[2] Univ Calabria, CRATIS Scrl, I-87036 Cosenza, Italy
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2007年 / 87卷 / 02期
关键词
D O I
10.1007/s00340-007-2607-9
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Forest fires can be the cause of serious environmental and economic damages. For this reason considerable effort has been directed toward forest protection and fire fighting. The means traditionally used for early fire detection mainly consist in human observers dispersed over forest regions. A significant improvement in early warning capabilities could be obtained by using automatic detection apparatus. In order to early detect small forest fires and minimize false alarms, the use of a lidar system and dial technique will be considered. A first evaluation of the lowest detectable concentration will be estimated by numerical simulation. The theoretical model will also be used to get the capability of the dial system to control wooded areas. Fixing the burning rate for several fuels, the maximum range of detection will be evaluated. Finally results of simulations will be reported.
引用
收藏
页码:373 / 378
页数:6
相关论文
共 30 条
[1]   A STUDY ON FOREST-FIRE AUTOMATIC DETECTION SYSTEMS .1. SMOKE PLUME MODEL [J].
ANDREUCCI, F ;
ARBOLINO, MV .
NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA C-GEOPHYSICS AND SPACE PHYSICS, 1993, 16 (01) :35-50
[2]   A STUDY OF FOREST-FIRE AUTOMATIC DETECTION SYSTEMS .2. SMOKE PLUME DETECTION PERFORMANCE [J].
ANDREUCCI, F ;
ARBOLINO, MV .
NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA C-GEOPHYSICS AND SPACE PHYSICS, 1993, 16 (01) :51-65
[3]   Improvement of Calabria university CO2 laser dial system [J].
Aversa, P ;
Bellecci, C ;
Michelangeli, GB ;
Caputi, G ;
DeDonato, F ;
Gaudio, P ;
Valentini, M ;
Zoccali, R .
LIDAR ATMOSPHERIC MONITORING, 1997, 3104 :154-157
[4]   NUMERICAL-ANALYSIS OF A CO2 SFUR LASER CAVITY [J].
BARBINI, R ;
COLAO, F ;
PETRI, A .
NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA D-CONDENSED MATTER ATOMIC MOLECULAR AND CHEMICAL PHYSICS FLUIDS PLASMAS BIOPHYSICS, 1991, 13 (02) :143-150
[5]  
BARBINI R, LIDAR ATMOSFERICO AS
[6]   Clipping the tail of a TE-CO2 laser pulse using a gas breakdown technique for high resolution chemical plume detection [J].
Bellecci, C ;
Bellucci, I ;
Gaudio, P ;
Martellucci, S ;
Petrocelli, G ;
Richetta, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (02) :1064-1069
[7]   Effect of the differential geometric form factor on differential absorption lidar measurements with topographical targets [J].
Bellecci, C ;
De Donato, F .
APPLIED OPTICS, 1999, 38 (24) :5212-5217
[8]   CO2 DIAL FOR MONITORING ATMOSPHERIC POLLUTANTS AT THE UNIVERSITY-OF-CALABRIA [J].
BELLECCI, C ;
CAPUTI, GEML ;
DEDONATO, F ;
GAUDIO, P ;
VALENTINI, M .
NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA C-GEOPHYSICS AND SPACE PHYSICS, 1995, 18 (05) :463-472
[9]  
Bellecci C., 2001, EUROPTO EUR S REM SE, V4539, P180
[10]  
BELLECCI C, 2005, REV SCI INSTRUM, V76