Aim There are no studies comparing tests performed at home with those carried out in the laboratory, using the same device. The only studies that have been performed have compared the device used at home with the standard polygraph used in the laboratory. The purpose of this study was therefore to verify the accuracy of the home diagnosis of obstructive sleep apnea syndrome (OSAS) via unassisted type 2 portable polysomnography, compared with polysomnography using the same equipment in a sleep laboratory. Methods To avoid any possible order effect on the apnea-hypopnea index (AHI), we randomly created two groups of 20-total 40 patients, according to the test sequence. One of the groups had the first test at home and the second test in the laboratory (H-L); the other group had the first test in the laboratory and the second at home (L-H). The second test always took place on the night immediately following the first test. All polysomnographic monitoring was undertaken with the same equipment, an Embletta X100 system (Embla, Natus Inc., Middleton, USA). The Embletta X100 is a portable polygraph that records eleven polygraph signs: (1) electroencephalogram C4/A; (2) electroencephalogram O2/M1; (3) submental EMG; (4) electrooculogram of the right side; (5) nasal cannula (air flow); (6) respiratory effort against a plethysmographic chest strap; (7) respiratory effort against an abdominal plethysmographic belt; (8) heart rate; (9) saturation of oxyhemoglobin; (10) snoring; and (11) body position. Results There was no difference in sleep efficiency between the group monitored in the laboratory and the group tested at home (p = 0.30). There was no difference in total sleep time (p = 0.11) or sleep latency (p = 0.52), or in the latency in phases N2 and N3 between the monitoring in the laboratory and at home (N2 p = 0.24; N3 p = 0.09). Some differences occurred regarding the PSG that took place at home, with longer duration of wake after sleep onset (WASO) and longer latency for REM sleep, due to failure of the patient to start the monitoring by pressing the "events" button on the device. In the distribution of sleep phases, there was no difference between the group monitored in the laboratory and the group tested at home. Conclusion Results from home sleep monitoring correlate well with the laboratory "gold standard" and may be an option for diagnosing OSAS in selected patients.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 50 条
  • [21] SEX DIFFERENCES IN PATIENTS WITH OBSTRUCTIVE SLEEP APNEA AND SUSPECTED HYPOVENTILATION ON HOME SLEEP APNEA TESTING
    Braganza, M.
    Tsai, W.
    Lee, M.
    Fraser, K.
    Hanly, P.
    Pendharkar, S.
    SLEEP MEDICINE, 2019, 64 : S297 - S298
  • [22] Accuracy and Acceptability of Level II Home Sleep Apnea Testing Compared to In-Lab Polysomnography in Children
    Cielo, C. M.
    Stefanovski, D.
    Ward, M.
    Falvo, J.
    Cornaglia, M.
    Tapia, I.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2022, 205
  • [23] Diagnostic accuracy of oximetry for obstructive sleep apnea: a study on older adults in a home setting
    Fraga da Rosa, Joao Carlos
    Peres, Alessandra
    Gasperin, Luciano
    Martinez, Denis
    Fontanella, Vania
    CLINICS, 2021, 76
  • [24] Belun Ring Platform: a novel home sleep apnea testing system for assessment of obstructive sleep apnea
    Gu, Wenbo
    Leung, Lydia
    Kwok, Ka Cheung
    Wu, I-Chen
    Folz, Rodney J.
    Chiang, Ambrose A.
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2020, 16 (09): : 1611 - 1617
  • [25] Comparison of home sleep apnea testing versus laboratory polysomnography for the diagnosis of obstructive sleep apnea in children
    Scalzitti, Nicholas
    Hansen, Shana
    Maturo, Stephen
    Lospinoso, Joshua
    O'Connor, Peter
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2017, 100 : 44 - 51
  • [26] LONGITUDINAL TESTING WITH A HOME SLEEP APNEA TEST SHOWS LARGE VARIABILITY IN NIGHTLY SLEEP APNEA SEVERITY
    Rohrscheib, Chelsie
    SLEEP, 2024, 47
  • [27] Home Sleep Testing for the Diagnosis of Obstructive Sleep Apnea-Indications and Limitations
    De Cruz, Sharon
    Littner, Michael R.
    Zeidler, Michelle R.
    SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 35 (05) : 552 - 559
  • [28] Loop Gain Measurements From Home Sleep Testing In Obstructive Sleep Apnea
    Orr, J. E.
    Sands, S. A.
    Edwards, B. A.
    Li, Y.
    Jen, R.
    Deacon, N. L.
    Malhotra, A.
    Owens, R. L.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [29] Home sleep testing for the diagnosis of pediatric obstructive sleep apnea: the times they are a changing ... !
    Gozal, David
    Kheirandish-Gozal, Leila
    Kaditis, Athanasios G.
    CURRENT OPINION IN PULMONARY MEDICINE, 2015, 21 (06) : 563 - 568
  • [30] BOARD REVIEW: Not so fast! Home sleep apnea testing
    Hadid, Ronny
    Skiba, Virginia
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2023, 19 (01): : 207 - 208