Aerodynamics of tip leakage flows near partial squealer rims in an axial flow turbine stage

被引:107
作者
Camci, C [1 ]
Dey, D [1 ]
Kavurmacioglu, L [1 ]
机构
[1] Penn State Univ, Dept Aerosp Engn, Turbomachinery Heat Transfer Lab, University Pk, PA 16802 USA
来源
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME | 2005年 / 127卷 / 01期
关键词
D O I
10.1115/1.1791279
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper deals with an experimental investigation of aerodynamic characteristics of full and partial-length squealer rims in a turbine stage. Full and partial-length squealer rims are investigated separately on the pressure side and on the suction side in the "Axial Flow Turbine Research Facility" (AFTRF) of the Pennsylvania State University. The streamwise length of these "partial squealer tips" and their chordwise position are varied to find an optimal aerodynamic lip configuration. The optimal configuration in this cold turbine study is defined as the one that is minimizing the stage exit total pressure defect in the tip vortex dominated zone. A new "channel arrangement" diverting some of the leakage flow into the trailing edge zone is also studied. Current results indicate that the use of "partial squealer rims" in axialflow turbines can positively affect the local aerodynamic field by weakening the tip leakage vortex. Results also show that the suction side partial squealers are aerodynamically superior to the pressure side squealers and the channel arrangement. The suction side partial squealers are capable of reducing the stage exit total pressure defect associated with the tip leakage flow to a significant degree.
引用
收藏
页码:14 / 24
页数:11
相关论文
共 21 条
[21]   INVESTIGATION OF 3-DIMENSIONAL FLOWFIELD AT THE EXIT OF A TURBINE NOZZLE [J].
ZACCARIA, M ;
LAKSHMINARAYANA, B .
JOURNAL OF PROPULSION AND POWER, 1995, 11 (01) :55-63