A compact, low-cost, quantitative and multiplexed fluorescence detection platform for point-of-care applications

被引:34
|
作者
Obahiagbon, Uwadiae [1 ]
Smith, Joseph T. [1 ,2 ]
Zhu, Meilin [2 ]
Katchman, Benjamin A. [2 ]
Arafa, Hany [1 ]
Anderson, Karen S. [2 ]
Christen, Jennifer M. Blain [1 ]
机构
[1] Arizona State Univ, Sch Elect Comp & Energy Engn, Goldwater Ctr, Suite 334, Tempe, AZ 85287 USA
[2] Arizona State Univ, Ctr Personalized Diagnost, Biodesign Inst, Tempe, AZ 85281 USA
基金
美国国家科学基金会;
关键词
Point-of-care; Diagnostics; Multiplexed; Fluorescence; Colorimetry; Limit of detection; INTEGRATION; SENSITIVITY; SENSORS;
D O I
10.1016/j.bios.2018.04.002
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An effective method of combating infectious diseases is the deployment of hand-held devices at the point-of-care (POC) for screening or self-monitoring applications. There is a need for very sensitive, low-cost and quantitative diagnostic devices. In this study, we present a low-cost, multiplexed fluorescence detection platform that has a high sensitivity and wide dynamic range. Our system features inexpensive 3 x 3 mm interference filters with a high stopband rejection, sharp transition edges, and greater than 90% transmission in the passband. In addition to the filters, we improve signal-to-noise ratio by leveraging time for accuracy using a charge-integration-based readout. The fluorescence sensing platform provides a sensitivity to photon flux of similar to 1 x 10(4) photons/mm(2) sec and has the potential for 2-3 orders of magnitude improvement in sensitivity over standard colorimetric detection that uses colored latex microspheres. We also detail the design, development, and characterization of our low-cost fluorescence detection platform and demonstrate 100% and 97.96% reduction in crosstalk probability and filter cost, respectively. This is achieved by reducing filter dimensions and ensuring appropriate channel isolation in a 2 x 2 array configuration. Practical considerations with low-cost interference filter system design, analysis, and system performance are also discussed. The performance of our platform is compared to that of a standard laboratory array scanner. We also demonstrate the detection of antibodies to human papillomavirus (HPV16) E7 protein, as a potential biomarker for early cervical cancer detection in human plasma.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 50 条
  • [1] Low-Cost Fluorescence Microscopy for Point-of-Care Cell Imaging
    Lochhead, Michael J.
    Ives, Jeff
    Givens, Monique
    Delaney, Marie
    Moll, Kevin
    Myatt, Christopher J.
    OPTICAL DIAGNOSTICS AND SENSING X: TOWARD POINT-OF-CARE DIAGNOSTICS, 2010, 7572
  • [2] Deep Learning Enabled Universal Multiplexed Fluorescence Detection for Point-of-Care Applications
    Kshirsagar, Aneesh
    Politza, Anthony J.
    Guan, Weihua
    ACS SENSORS, 2024, 9 (08): : 4017 - 4027
  • [3] A low-cost miniaturized potentiostat for point-of-care diagnosis
    Cruz, Andres Felipe Diaz
    Norena, Nicolas
    Kaushik, Ajeet
    Bhansali, Shekhar
    BIOSENSORS & BIOELECTRONICS, 2014, 62 : 249 - 254
  • [4] Low-cost, point-of-care biomarker quantification
    Piorino, Fernanda
    Patterson, Alexandra T.
    Styczynski, Mark P.
    CURRENT OPINION IN BIOTECHNOLOGY, 2022, 76
  • [5] A Dedicated Low-Cost Fluorescence Microfluidic Device Reader for Point-of-Care Ocular Diagnostics
    Pestana, Noah
    Walsh, David
    Hatch, Adam
    Hahn, Paul
    Jaffe, Glenn J.
    Murthy, Shashi K.
    Niedre, Mark
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2013, 7 (02):
  • [6] Cancer marker detection in human serum with a point-of-care low-cost system
    Grosso, Pasquale
    Carrara, Sandro
    Stagni, Claudio
    Benini, Luca
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 147 (02): : 475 - 480
  • [7] Low-Field, Low-Cost, Point-of-Care Magnetic Resonance Imaging
    Samardzija, Anja
    Selvaganesan, Kartiga
    Zhang, Horace Z.
    Sun, Heng
    Sun, Chenhao
    Ha, Yonghyun
    Galiana, Gigi
    Constable, R. Todd
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2024, 26 : 67 - 91
  • [8] A hydrogel sensor-based microfluidic platform for the quantitative and multiplexed detection of fertility markers for point-of-care immunoassays
    Kalme, Satish
    Kandaswamy, Srinivasan
    Chandrasekharmath, Anusha
    Katiyar, Reeta
    Rajamanickam, Gokul Prasath
    Kumar, Suraj
    Dendukuri, Dhananjaya
    ANALYTICAL METHODS, 2019, 11 (12) : 1639 - 1650
  • [9] A Low-Cost Point-of-Care System for Parallel ELISA Essays
    Grosso, Pasquale
    Carrara, Sandro
    Stagni, Claudio
    Benini, Luca
    2009 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS 2009), 2009, : 244 - +
  • [10] Rethinking the Design of Low-Cost Point-of-Care Diagnostic Devices
    Kimani, Faith W.
    Mwangi, Samuel M.
    Kwasa, Benjamin J.
    Kusow, Abdi M.
    Ngugi, Benjamin K.
    Chen, Jiahao
    Liu, Xinyu
    Cademartiri, Rebecca
    Thuo, Martin M.
    MICROMACHINES, 2017, 8 (11)